Geri Dön

All-on-four sistem planlanan hastalarda distal implantın sonlu eleman analizi ile stres dağılımının incelenmesi

Evaluation of stress distribution on distal implant in patients with all-on-four system planned by finite element analysis

  1. Tez No: 817488
  2. Yazar: YILDIZ ÜNÜVAR
  3. Danışmanlar: DOÇ. DR. AYLİN ÇALIŞ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Bilim Dalı
  13. Sayfa Sayısı: 110

Özet

Amaç: Alt çenelerde rezorpsiyon sonucu inferior alveolar sinir ve kret tepesi arasındaki vertikal kemik yüksekliği dental implant yerleşimi için yetersiz hale gelebilmektedir. İhtiyaç duyulan bu kemik hacmini sağlamak için kemik rejenerasyon yöntemlerine, distraksiyon işlemlerine, horizontal veya vertikal augmentasyonlara, kret split ya da kret ekspansiyonu gibi ileri cerrahi işlemlere ihtiyaç duyulabilmektedir. Buna bağlı olarak tedavi süresi ve maliyetler artmaktadır. Bu tür hastalarda sabit protez kullanımına olanak sağlamak için ''All-on-four'' adı verilen teknik geliştirilmiştir. Bu teknikte interforaminal alanda anterior bölgeye vertikal yerleştirilen 2 adet implant ve posterior bölgeye 45 dereceye kadar artabilen farklı açılarda distale eğimli olarak yerleştirilen 2 adet implant kullanılmaktadır. Çalışmamızda da posteriordaki bu açılı implantların açı farkına bağlı olarak kemik, implant, abutment, diş eti ve protez üzerinde oluşan stres miktarının değerlendirilmesi amaçlanmıştır. Aynı zamanda standart implantlara ek olarak boyun kısmı açılı implantlar kullanılmıştır. Yöntem: Ansys Workbench (ANSYS Inc. Houston, PA, ABD) yazılımı kullanılarak Medentika®(MEDENTiKA GmbH, Hügelsheim, Almanya) firmasının 13 mm uzunluğunda ve 4,3 mm çapında boyun kısmı 30 derece eğimli 3B (katı) implant modeli ve 13 mm uzunluğunda 4,3 mm çapında standart 3B (katı) implant modeli hazırlanıp D2 kemik yapısına uygun olarak düzenlenmiş dişsiz mandibula modeline distale doğru 15°, 30°, 45° ve boyun kısmı açılı implant için 30° olacak şekilde uygulanmıştır. 200 N altında maksimum ve minimum asal gerilimler, von Mises stres değerleri ve protezdeki yer değiştirme miktarı ölçülmüştür. Bulgular: Uygulanan kuvvet sonucunda kemikteki en yüksek minimum asal stres değeri 15 ve 30 derecelik modelde(-37.7 MPa) en düşük minimum asal stres değeri boyun kısmı açılı implantta(-30.5 MPa) görülmüştür. En yüksek maksimum asal stres değeri boyun kısmı açılı implantta(8.79 MPa) en düşük maksimum asal stres değeri 45 derecelik modelde(3.82 MPa) görülmüştür. Modellere ait açılı implantların boyun bölgesinde oluşan maksimum von Mises stres değerleri sırasıyla Model 1'de 177 MPa, Model 2'de 192 MPa, Model 3'te 282 ve Model 4'te 305 MPa olarak ölçülmüş ve en düşük değerin boyun kısmı açılı implantta olduğu görülmüştür. Abutmentlar üzerindeki en düşük von Mises stres değeri de 225 MPa olarak boyun kısmı açılı implanta aittir. Birinci molar diş bölgesinde protez üzerindeki en büyük yer değiştirme miktarı sırasıyla Model-2 (0.82 mm)de en düşük yer değiştirme miktarı Model 1'de (0.69 mm) ölçülmüştür. Sonuç: Uygulanan fonksiyonel yükler altında çalışmamız için yapılan tüm modellerde oluşan stres değerleri implantların boyun bölgesinde yoğunlaşmıştır. Bu kuvvetlere bağlı olarak oluşabilecek kemik rezorbsiyonları ve implant kırıklarının boyun bölgesinde olması öngörülebilir. Fakat çalışmamızdaki modellerde tüm bu değerler fizyolojik sınırlardadır. Aynı zamanda boyun bölgesi açılı implantlar değerlendirildiğinde standart implant uygulamalarına göre en düşük von Mises stres değerlerine sahip olduğu görülmüştür. Çalışmamızda yapılan analizler sonucu elde edilen verilerin, in vivo çalışmalar ve klinik uygulamalar ile desteklenmesinin daha etkili sonuçlar oluşturacağını öngörmekteyiz .

Özet (Çeviri)

Objective: As a result of resorption in the mandibles, the vertical bone height between the inferior alveolar nerve and the crest may become inadequate for dental implant placement. Bone regeneration methods, bone distraction procedures, horizontal or vertical augmentations, crest split or bone expansions may be needed to provide this required bone volume. As a result of these procedures, treatment time and costs increase. A technique called“All-on-four”has been developed to allow the use of fixed prosthesis in such patients. In this technique, 2 implants placed vertically in the anterior region in interforaminal area and 2 implants placed distally inclined at angles that can increase up to 45 degrees are used in the posterior region. The aim of our study is to evaluate the amount of stress caused by posterior angled implants on bone, implant, abutment, gingiva and prosthesis. Furthermore a sloped implant was used in addition to the standard implant. Materials/Methods: Using Ansys Workbench (ANSYS Inc. Houston, PA, USA) software, a 3D (solid) implant model of Medentika®(MEDENTiKA GmbH, Hügelsheim, Germany) with a length of 13 mm and a diameter of 4.3 mm with a 30-degree sloped and a straight 3D (solid) implant model with a length of 13 mm and a diameter of 4.3 mm was prepared. In addition, it was placed to the edentulous mandible model with in the D2 bone structure at 15, 30, 45 degrees in the distal direction and 30 degrees for the sloped implant. Maximum and minimum principal stresses, von Mises stress distrubition and displacement of the prosthesis were measured by applying 200 N force. Results: As a result of the applied force, the highest minimum principal stress value in the bone was observed in the 15 and 30 degree model(-37.7 MPa) and the lowest minimum principal stress value in the sloped implant (-30.5 MPa). The highest maximum principal stress value was observed in the sloped neck implant(8.79 MPa) and the lowest maximum principal stress value was observed in the 45 degree model(3.82 MPa). The maximum von Mises stress values in the neck region of the angled implants of the models were measured as 177 MPa in Model 1, 192 MPa in Model 2, 282 MPa in Model 3 and 305 MPa in Model 4 and the lowest value was observed in the sloped neck implant. The lowest von Mises stress value on the abutments was 225 MPa for the sloped implant. The maximum displacement on the prosthesis in the first molar region was measured in Model-2 (0.82 mm) and the minimum displacement amount was measured in Model 1 (0.69 mm). Conclusion: The stress values that occur under the applied functional loads are concentrated in the neck region of the implants in all models. As a result, it can be predicted that bone resorption and implant fractures will occur in the neck region. However, in the models in our study, all these values are within physiological limits. Furthermore, when the sloped neck implants were evaluated, it was seen that they had the lowest von Mises stress values compared to standard implants. We predict that supporting our study with in vivo and clinical studies will create more effective results.

Benzer Tezler

  1. Benign prostat hiperplazili olgularda dört farklı alfa blokerin lipid profili üzerine yaptığı değişiklikler

    Comparison of the effects of four different alpha blockers on the lipid profile in patients with benign prostatic hyperplasia

    SÜLEYMAN ÜLGER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    ÜrolojiMersin Üniversitesi

    Üroloji Ana Bilim Dalı

    DOÇ. DR. MURAT BOZLU

  2. Pediatrik dental girişimlerde müzik dinletilmesinin sedasyon gereksinimi ve düzeyine etkisi

    The effects of music on sedation depth and necessity during pediatric dental procedures

    ÖZLEM ÖZKALAYCI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Anestezi ve ReanimasyonBaşkent Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    YRD. DOÇ. DR. COŞKUN ARAZ

  3. Solid organ tümörü olan erişkin hastalarda hepatit B virüsü hepatit C virüsü HIV enfeksiyonu tarama sıklığının ve prevalanslarının saptanması

    Determination of screening frequency and prevalences for hepatitis B virus hepatitis C virus HIV infection in adult patients with solid organ tumor

    ŞEYHMUS ABAKAY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    OnkolojiDokuz Eylül Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HÜSEYİN SALİH SEMİZ

  4. Sitomegalovirüs spesifik T hücre yanıtının flow sitometri yöntemi ile optimizasyonu

    Optimization of cytomegalovirus specific T cell response via flow cytometry

    HAFİZE KILINÇKAYA DOĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    MikrobiyolojiAkdeniz Üniversitesi

    Tıbbi Mikrobiyoloji Ana Bilim Dalı

    PROF. DR. MERAL GÜLTEKİN

  5. Mide kanserinin tedavisinde uygulanan yoğunluk ayarlı radyoterapi planlama sistemi ile 3D konformal radyoterapi sisteminde kritik organ dozlarının karşılaştırılması

    Comparison of dose distrubution for critical organs with intensitiy modulated radiation therapy and 3D conformal radiotherapy for gastric cancer

    KUDRET BEKTAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    OnkolojiGaziantep Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    YRD. DOÇ. DR. ABDURAHMAN KUZHAN