Poli-eter-eter-keton (PEEK) ve poli-eter-keton-keton (PEKK) ile üretilmiş altyapılarda konnektör kalınlığının kırılma direncine etkisinin değerlendirilmesi
Evaluation of the effect of connector thickness on fracture strength in framework manufactured with poly-ether-ether-ketone (PEEK) and poly-ether-ketone-ketone (PEKK)
- Tez No: 838247
- Danışmanlar: PROF. DR. MUSTAFA ZORTUK
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Hatay Mustafa Kemal Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 80
Özet
Giriş ve Amaç: Yüksek performanslı polimer materyaller olan PEEK ve PEKK, mükemmel fiziksel özellikleri nedeniyle son zamanlarda posterior implant destekli restorasyonlarda kullanılmaktadır. Ancak PEEK ve PEKK materyallerinden üretilmiş implant destekli altyapıların kırılma dayanımları belirsizliğini korumaktadır. Bu çalışmanın amacı farklı konnektör kesit alanına sahip iki implant destekli üç üyeli kobalt-krom, PEEK ve PEKK altyapıların kırılma dayanıklılıklarını karşılaştırmaktır. Gereç ve Yöntem: Kırılma dayanıklılığının değerlendirilmesi için 126 adet standart titanyum abutment (Nucleoss, İzmir, Türkiye) analoga vidalanarak akrilik blokların içine tek diş boşluğunu taklit edecek şekilde ikişerli olarak gömüldü. Altyapılar bilgisayar destekli tasarım yazılımıyla konnektör yüzey alanları 6.25 mm2, 12 mm2 ve 16 mm2 olacak şekilde tasarlandı. Üç farklı konnektör kalınlığında, üç farklı materyalden her grupta 7 adet olacak şekilde toplamda 63 altyapı üretildi. Daha sonra altyapılar çinkofosfat siman ile dayanaklara simante edilerek üniversal kırılma cihazında kırılma testine tabii tutuldu. Elde edilen sonuçlar Kruskal Wallis Testi ve Bonferroni düzeltmeli Mann Whitney U testi uygulanarak istatistiksel olarak değerlendirildi. Bulgular: PEEK altyapılar hem plastik deformasyon hem kırılma gösterirken, PEKK ve kobalt-krom altyapılar tam kırılma gösterdi. En yüksek ortalama kırılma dayanıklılığı kobalt-krom grubunda (7326N ± 1071,6N), sonrasında PEEK (1485N ± 116,4N), sonrasında PEKK grubunda(995 N ± 180,8N) gözlendi. Konnektör kesit alanında en yüksek ortalama kırılma dayanıklılığı 16mm2 grubunda, sonrasında 12mm2, sonrasında 6,25mm2 grubunda gözlendi. Co-cr ve PEKK grubunda konnektör yüzey alanının 12mm2'den 16 mm2'ye çıkarılmasıyla oluşan kırılma dayanımı değeri farkı istatistiksel olarak anlamlı bulunmadı. Tüm grupların ortalama kırılma dayanımı değeri posterior bölgedeki fizyolojik güçlere karşı koyacak kapasitede bulundu. Sonuç: Bu in vitro çalışmanın limitasyonları dahilinde PEEK ve PEKK materyali posterior bölge implant destekli sabit protezler için alternatif bir altyapı materyali olarak kullanılabilir.
Özet (Çeviri)
Introduction and Aim: PEEK and PEKK, which are high performance polymer materials, have recently been used in posterior implant supported restorations due to their excellent physical properties. However, the fracture strength of implant-supported frameworks made of PEEK and PEKK materials remains uncertain. The aim of this study is to compare the fracture strength of two implant-supported three-unit cobalt-chromium, PEEK and PEKK frameworks with different connector cross-sectional areas. Material and Methods: To evaluate the fracture strength, 126 standard titanium abutments were screwed to the analogs and embedded in the acrylic blocks in pairs to mimic a missing single mandibular premolar. The frameworks were designed with a CAD software program with connector surface areas of 6.25 mm2, 12 mm2 and 16 mm2. A total of 63 frameworks were fabricated, 7 in each group, in 3 connector cross-sectional areas out of 3 materials (co-cr, PEEK, PEKK). Afterwards, the frameworks were cemented to the abutments with zincphosphate cement. A universal testing machine was used for fracture strength analysis, and the failure mode was recorded. The obtained data were statistically evaluated by running the Kruskal Wallis Test and the Mann Whitney U test with Bonferroni correction. Results: PEEK frameworks showed both plastic deformation and fracture, while PEKK and cobalt-chromium frameworks showed complete fracture. The highest mean fracture strength was observed in the 16mm2 group, followed by 12mm2, and then 6.25mm2 in the connector cross-sectional area. The highest mean fracture strength values were observed in the cobalt-chromium frameworks (7326N ± 1071,6N), followed by PEEK (1485N ± 116,4N), and then in the PEKK frameworks (995 N ± 180,8N). The difference in fracture strength value that occurred by increasing the connector surface area from 12mm2 to 16mm2 in Co-Cr and PEKK frameworks was not found statistically significant. The mean fracture strength value of all groups was found to be capable of withstanding the physiological forces in the posterior region. Conclusions: Within the limitations of this in vitro study, PEEK and PEKK can be used as an alternative framework material for posterior implant-supported 3-unit fixed dental prostheses.
Benzer Tezler
- Borik asit katkılı speek/pva kompozit membranı sentezlenmesi ve karakterizasyon çalışmaları
Synthesis and characterization studies for boric acid dopped speek/pva composite membrane
TUĞÇE NUR KARAMETE
Yüksek Lisans
Türkçe
2019
Kimya MühendisliğiGazi ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
PROF. DR. İRFAN AR
- Farklı materyallerle hazırlanmış içbükey çıkış profiline sahip bireysel dayanakların kırılma dayanımları ve yük altında kuvvet dağılımlarının araştırılması
Evaluation of fracture strength and stress distribution of convex shaped individual abutments under load fabricated from different materials
FATMA ERŞİL
Doktora
Türkçe
2019
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. MEHMET SONUGELEN
- Development of novel thermal conductive polymer nanocomposites
Yeni nesil termal iletken polimer nanokompozitlerin geliştirilmesi
ELİFTEN SEMERCİ
Doktora
İngilizce
2021
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. NİLGÜN KIZILCAN
DOÇ. DR. TUBA ERDOĞAN BEDRİ
- Isıl yaşlanma ve takviye malzemesi türünün poli(eter eter keton) kompozitlerin özellikleri üzerine etkisi
Thermal aging and reinforcement type effects on the properties of poly(ether ether ketone) composites
RECEP ŞADİ DEMİRKOL
Yüksek Lisans
Türkçe
2019
Polimer Bilim ve TeknolojisiKocaeli ÜniversitesiPolimer Bilim ve Teknolojisi Ana Bilim Dalı
PROF. DR. TANER YILMAZ
- Bruksizmli hastalarda peek, zirkonyum ve titanyum dental implant materyallerinin D1-D4 kemik densitelerinde oluşturdukları stres dağılımlarının sonlu elemanlar metodu ile incelenmesi
Finite element analysis of stress distribution of peek, zirconia and titanium dental implant materials on D1-D4 bone densities in patients with bruxism
AYŞE NUR SAKAL
Diş Hekimliği Uzmanlık
Türkçe
2023
Diş HekimliğiKaradeniz Teknik ÜniversitesiAğız Diş ve Çene Cerrahisi Ana Bilim Dalı
DOÇ. DR. EFE CAN SİVRİKAYA