Tek foton emisyon tomografisinde kristal ölü tabakasının sistem performansı üzerine etkisinin incelenmesi

Investigation of the effect of crystal dead layer on system performance in single photon emission tomography

  1. Tez No: 864224
  2. Yazar: HİLAL USLU AYNUR
  3. Danışmanlar: PROF. DR. TUNCAY BAYRAM
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: GEANT4, Kontrast, Monte Carlo, Ölü tabaka, Tek Foton Emisyon Tomografi, Contrast, Dead layer, GEANT4, Monte Carlo, Single Photon Emission Tomography
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Karadeniz Teknik Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 61

Özet

Günümüzde nükleer tıp alanında sıkça kullanılan SPECT (Tek Foton Emisyon Tomografi) etkin bir tanısal görüntüleme cihazıdır. Hasta vücuduna verilen radyofarmasötik maddeden yayılan gama ışınlarının sayılması ve bilgisayar sisteminde işlenerek kesitsel görüntülerin oluşturulması ilkesine dayanır. Elde edilen görüntülerin kalitesi hastalıkların doğru teşhis edilmesi açısından oldukça önemlidir. Görüntü kalitesinin en iyi düzeyde olması ancak cihazın kalite kontrol testlerinin düzenli olarak yapılması ile mümkündür. SPECT uygulamalarında görüntü kalitesini etkileyen faktörlerden biri de dedektör bileşenlerinden biri olan sintilasyon kristalinde zamanla oluşan ölü tabakadır. Bu çalışmada SPECT'te kullanılan NaI(Tl) sintilasyon kristalinde oluşabilecek ölü tabakaların sistem performansı üzerine etkisi incelenmiştir. Bu amaçla Monte Carlo yöntemi tabanlı bir simülasyon paketi olan GEANT4'e dayalı GATE benzetim kodu kullanıldı. İlk adımda standart SPECT modeli benzetimi yapılarak nükleer tıpta kullanılan düşük 140 keV (99mTc için), orta 167 keV (201Tl için) ve yüksek 364 keV (131I için) gama enerjilerinde SPECT performans parametreleri (Hassasiyet, uzamsal çözünürlük, enerji çözünürlüğü, kontrast) incelendi. Daha sonra benzetimi yapılan kristalin üzerine farklı kalınlıklarda ölü katmanlar oluşturularak aynı enerjiler için ölü tabakanın performans parametrelerine etkisi araştırıldı. Sonuç olarak, sintilasyon kristalinin ölü tabakasındaki artışa bağlı olarak SPECT sisteminin görüntü kalite değerlendirme parametrelerinde kötüleşmeler meydana geldiği görüldü.

Özet (Çeviri)

SPECT (Single Photon Emission Tomography), which is frequently used in nuclear medicine today, is an effective diagnostic imaging device. It is based on the principle of counting the gamma rays emitted by the radiopharmaceutical substance given to the patient's body and creating cross-sectional images by processing them in the computer unit. The quality of the images obtained is very important for the correct diagnosis of diseases. The best image quality is only possible with regular quality control tests of the device. One of the factors affecting image quality in SPECT applications is the dead layer that forms over time in the scintillation crystal, one of the detector components. In this study, the effect of dead layers in NaI (Tl) scintillation crystal used in SPECT on system performance was investigated. For this purpose, the GATE simulation code based on GEANT4, a simulation package use the Monte Carlo method, was used. In the first step, the standard SPECT model was simulated and SPECT performance parameters (Sensitivity, spatial resolution, energy resolution, contrast) at low 140 keV (for 99mTc), medium 167 keV (for 201Tl) and high 364 keV (for 131I) gamma energies used in nuclear medicine were analyzed. Then, dead layers of different thicknesses were formed on the simulated crystal and the effect of the dead layer on the performance parameters was evaluated for the same energies. As a result, it was observed that the increase in the dead layer of the scintillation crystal resulted in deterioration of the image quality assessment parameters of the SPECT system.

Benzer Tezler

  1. Bilgisayarlı tek foton emisyon tomografisinde kalp tetkiklerinde foton azalım düzeltmesinin incelenmesi

    Investigation of photon attenuation correction techniques for cardiac studies in single in single photon emission computed tomography

    DEVRİM DEMİRAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    PROF.DR. DOĞAN BOR

  2. Quality controls of single photon emission computed tomography - computed tomography imagining device

    Tek foton emisyon bilgisayarlı tomografi - bilgisayarlı tomografi görüntüleme cihazının kalite kontrolleri

    DUYGU TUNÇMAN GENÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. BAYRAM DEMİR

  3. Obsesif kompulsif bozuklukta sertralinin bölgesel beyin kan akımına etkisinin spect yöntemi ile incelenmesi

    Assessment of effect of sertraline on regional cerebral blood flow by using spect imaging method in obsessive compulsive disorder

    AYTEKİN ŞAHAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2007

    PsikiyatriGATA

    Ruh Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ.DR. SERVET EBRİNÇ