Geri Dön

Pediatrik suprakondiler humerus kırıklarında medial kolon parçalanma miktarının ve farklı K-teli konfigürasyonlarının sentetik kemik modelinde biyomekanik değerlendirilmesi

Biomechanical evaluation of medial column comminution amount and different K-wire fixation configurations in synthetic bone models of pediatric supracondylar humerus fractures

  1. Tez No: 878965
  2. Yazar: MUHAMMED ABDULKADİR BULUT
  3. Danışmanlar: PROF. DR. GÜNEY YILMAZ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Humeral kırıklar, Kırık fiksasyonu, Humeral fractures, Fracture fixation
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Suprakondiler humerus kırıkları (SHK) çocukluk çağının en sık cerrahi gerektiren kırıklarındandır. Redüksiyon kaybı %3-15 oranlarında görülebilmektedir. Redüksiyon kaybının en sık nedeni cerrahi teknikteki yetersizlikler olsa da medial kolon parçalanması, alçak kırıklar, sagital oblik kırıklar gibi kırık morfolojileri de stabiliteyi azaltmakta ve redüksiyon kaybı riskini arttırmaktadır. Bu çalışmanın amacı biyomekanik olarak medial kolon parçalanmasının boyutunun stabiliteye etkisinin ve medial kolon parçalanmasında kullanılabilecek olan üç K-telli konfigürasyonlarının stabilitelerinin araştırılmasıdır. 120 sentetik humerus kemiği ve 700 adet Kirschner teli temin edildi. 20'şer kemikten oluşan altı grup oluşturuldu. Lateral girişli diverjan üç K-teli (3LDP) ve iki lateral girişli bir medial girişli çapraz üç K-teli (3XP) konfigürasyonlarına ve medial taraftan kırık hattının %25'i ve %50'si olacak şekilde kama çıkarılması planlanarak gruplar oluşturuldu. Torsiyon ve varus bükme testleri uygulandı. Bu testlerde sertlik, maksimum tork/yük verileri ve kırık hattındaki değişim fotoğrafları elde edildi. .Verilerin değerlendirilmesi için ANOVA, Mann Whitney U ve Fischer LSD ikili karşılaştırma testleri kullanıldı. Torsiyon testinde 3XP konfigürasyonunun sertliği ve maksimum torku 3LDP konfigürasyonuna göre daha yüksek bulundu. 5° ve 10° rotasyonlar için gereken tork değerleri kama çıkarılmayan 3XP konfigürasyonu grubunda kama çıkarılan gruplara göre anlamlı olarak daha yüksek bulundu. Varus bükme testinde konfigürasyonların arasında anlamlı fark yoktu. Çıkarılan kama boyutunun 3XP konfigürasyon gruplarında stabiliteye anlamlı bir etkisi bulunamadı. 3LDP konfigürasyonu gruplarında büyük kama çıkarılan grubun maksimum yükü kama çıkarılmayan gruba göre anlamlı olarak daha düşükken, sertlikleri açısından anlamlı fark olmasa da daha az sertliğe sahip olduğu görüldü. Konfigürasyonların kırık hattındaki değişiminin anlamlı bir fark oluşturmadığı görüldü. Kama çıkarılması sonucu bütün konfigürasyonlarda kırık hattında anlamlı bir değişim olurken, 3XP konfigürasyonunda kama boyutunun kırık hattındaki değişime anlamlı bir etkisinin olmadığı görüldü. Üç K-teli ile oluşturulan konfigürasyonlarda kama boyutunun ve kama çıkarılmasının sertliğe anlamlı bir etkisinin olmadığı görüldü. 3LDP konfigürasyon gruplarında büyük kama çıkarılması varus bükme testinde maksimum yükü anlamlı olarak düşürürken 3XP gruplarında böyle bir bulgu yoktu. 3XP konfigürasyonunda kama çıkarılması kırık hattında anlamlı bir değişim yaparken, kama boyutunun buna bir etkisi olmadığı görüldü. Medial kolonun parçalanması durumunda biyomekanik olarak 3XP konfigürasyonu bu bulgulara göre en stabil ve güvenli konfigürasyondur.

Özet (Çeviri)

Supracondylar humerus fractures (SHF) are among the most common fractures in childhood requiring surgery. Loss of reduction can occur at rates of 3-15%. Although the most frequent cause of reduction loss is deficiencies in surgical technique, fracture morphologies such as medial column fragmentation, low fractures, and sagittal oblique fractures also reduce stability and increase the risk of reduction loss. The aim of this study is to biomechanically investigate the effect of the size of medial column fragmentation on stability and the stabilities of three K-wire configurations that can be used in medial column fragmentation. 120 synthetic humerus bones and 700 Kirschner wires were obtained. Six groups of 20 bones each were formed. Groups were created by planning the removal of wedges to account for 25% and 50% of the fracture line on the medial side for the lateral divergent three K-wires (3LDP) and the cross three K-wires (3XP) configurations, which include two lateral and one medial entry. Torsion and varus bending tests were applied. Data on stiffness, maximum torque/load, and photographs of changes at the fracture line were obtained in these tests. ANOVA, Mann Whitney U, and Fischer LSD pairwise comparison tests were used for data evaluation. In the torsion test, the stiffness and maximum torque of the 3XP configuration were found to be higher than those of the 3LDP configuration. The torque values required for 5° and 10° rotations were significantly higher in the 3XP configuration group without wedge removal compared to the groups with wedge removal. There was no significant difference between the configurations in the varus bending test. The size of the removed wedge had no significant effect on stability in the 3XP configuration groups. In the 3LDP configuration groups, the maximum load of the group with large wedge removal was significantly lower than that of the group without wedge removal, while there was no significant difference in stiffness, although it was observed to be less stiff. It was observed that the changes at the fracture line due to the configurations did not result in a significant difference. While there was a significant change at the fracture line in all configurations due to wedge removal, the size of the wedge did not have a significant effect on the change at the fracture line in the 3XP configuration. In the configurations created with three K-wires, it was observed that the size of the wedge and the removal of the wedge had no significant effect on stiffness. In the 3LDP configuration groups, large wedge removal significantly reduced the maximum load in the varus bending test, while there was no such finding in the 3XP groups. While wedge removal caused a significant change at the fracture line in the 3XP configuration, the size of the wedge had no effect on this change. Biomechanically, the 3XP configuration is the most stable and safe configuration in cases of medial column fragmentation according to these findings.

Benzer Tezler

  1. Gelişim nörolojisi polikliniğine başvuran nöral tüp defektli olgularda prospektif bir inceleme

    Başlık çevirisi yok

    İLKBAHAR EMİNE GÜLTEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    Yükleniyor...

  2. Boğazdan izole edilen coliform bakterilerin B- laktamaz enzim aktivitelerinin tesbit edilmesi ve B-laktamaz pozitif coliformların penisilinetkisinin inaktivasyonunun in vitro deneylerle gösterilmesi

    The Detection of beta-lactamasa activity of coliform bacteria isolated from th roat cultures and slovving the inactivation of penicilin by this beta lactamase produced by this caliform organisms

    GÜVEN URAZ

    Doktora

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Genel Biyoloji Ana Bilim Dalı

    Yükleniyor...

  3. Akut lenfoblastik lösemide monoklonal antikorlarla fenotipik özelliklerin ve T-lenfotropik virus antikorlarının incelenmesi

    Başlık çevirisi yok

    HAYAT ERDEM

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Hacettepe Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    Yükleniyor...

  4. Kronik hastalığı olan çocukların hastalığa ve hastaneye yatmaya tepkileri

    Başlık çevirisi yok

    MEDİHA DOĞANAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    İstanbul Üniversitesi

    Yükleniyor...