Özet

Biyolojik ve kimyasal analitik cihazların mikroelektromekanik sistemler (MEMS) teknolojisi ile minyatürleştirilmesi, tıbbi ve mikrobiyolojik teşhis ve diğer biyolojik analizler için önemli olmuştur. Mevcut veya ortaya çıkmakta olan bulaşıcı hastalıklar, zamanında teşhisi iyileştirmek için hasta başında (POC) test ihtiyacını arttırmaktadır. Nükleik asit tespiti için geleneksel yöntemler birçok adım gerektirmektedir. Bu teknolojilerin bazıları yüksek hassasiyette olabilir. Ancak, düşük algılama limitleri, zaman ve enstrümantasyon gereksinimleri nedeniyle POC cihazlarını geliştirmede geride kalmaktadır. Bu zorlukların üstesinden gelmek için, örnek ön işleme, reaksiyonlar, ayırmalar ve teşhis dahil tüm analitik adımların küçük bir çip üzerindeki mikro kanallarda verimli ve otomatik olarak gerçekleştirilmesine izin veren mikroakışkan teknolojiler kullanılmaktadır. Nükleik asit amplifikasyon yöntemlerinden biri olan polimeraz zincir reaksiyonu veya zincirleme polimeraz reaksiyonu (PCR), basitliği nedeniyle en çok kullanılan yöntem olmuştur. Mikroakışkan teknolojiler, PCR işlemlerinin hız, maliyet, taşınabilirlik, verim ve otomasyon gibi potansiyel faydaları olan bir çipte minyatürleştirilmesini sağlamaktadır. Tez çalışması ile PCR gerçekleştirebilmek için gerekli olan mikroçip ve mikro sıcaklık döngüleyici tasarımı ve üretimi gerçekleştirilmiştir. Bu amaçla yapılan mikroçip tasarımında Bilgisayar Destekli Tasarım (CAD) programı kullanılmış, üretiminde ise CAD yöntemlerinden biri olan lazer kesici kullanılmış ve tek odacıklı bir çip üretilmiştir. Mikroçip üretiminde kullanılan malzemeler lamel, çift taraflı bant (DSA) ve polimetilmetakrilat (PMMA) polimeri olmuştur. Mikro sıcaklık döngüleyici üretiminde kullanılmak üzere ısıtıcı eleman olarak Peltier modülü seçilmiştir. Sıcaklık kontrollerinin gerçekleştirilmesinde mikrodenetleyici ve H-Köprü modülleri kullanılmıştır. Sıcaklık döngüleyici devre analizi öncelikle bir simülasyon programında yapılmış ve PCR döngüsü gerçekleştirilebilmiştir. Daha sonra bu devreyi gerçekleyebilmek için uygun elemanlar temin edilmiştir. H köprü tipi sürücülerin modları, mikrodenetleyici ile nasıl sürüldüğüne ilişkin devre düzeneklerinin çalışması yapılmıştır. Motor sürme tekniklerinden biri olan darbe genişlik modülasyonu (PWM) tekniği ile H köprü sürme (bir mikrodenetleyici yardımı ile) denenmiştir. Temin edilen elemanlar ile öncelikle peltier modül sıcaklık testleri gerçekleştirilmiştir. Uygunlukları test edilen devre elemanları ile sıcaklık döngüsü kontrolü için geliştirilen PID kontrol algoritması birleştirilerek PCR döngüsü gerçekleştirilmiştir. Isı transferi ve akışkan akışını simüle etmek için farklı bir CAD programı daha kullanılmıştır. Bu yazılım sonlu-eleman yöntemine dayanmaktadır. Fiziğin farklı alanlarından kısmi diferansiyel denklemleri birleştirmek ve çözmek için kolaylık sağlamaktadır. Akışkan akış modülü kullanılarak mikroçip içerisinde laminar akış simüle edilmiştir. Ayrıca ısı transfer modülü kullanılarak çip malzemelerindeki ısı transferi simüle edilmeye çalışılmıştır. Tasarlanan mikro sıcaklık döngüleyici ile DNA örneği, Kırıkkale Üniversitesi Tıp Fakültesi Tıbbi Biyoloji Anabilim Dalında amplifiye edilmiştir. Yapılan tasarımın PCR gerçekleştirdiğini test edebilmek için, sıcaklık döngüleyici üzerinde kullanılan örnek ticari bir sıcaklık döngüleyici kullanılarak da amplifiye edilmiş ve sonrasında uygun bir analiz yöntemiyle sonuçlar belirlenmiştir.

Özet (Çeviri)

Miniaturization of biological and chemical analytical devices with microelectromechanical systems (MEMS) technology has been important for medical and microbiological diagnostics and other biological analyses. Existing or emerging infectious diseases are increasing the need for point-of-care (POC) testing to improve timely diagnosis. Traditional methods for nucleic acid detection require many steps. Some of these technologies can be highly sensitive. However, it lags behind in developing POC devices due to low detection limits, time and instrumentation requirements. To overcome these challenges, microfluidic technologies are used that allow all analytical steps, including sample pretreatment, reactions, separations, and diagnostics, to be performed efficiently and automatically in microchannels on a small chip. Polymerase chain reaction (PCR), one of the nucleic acid amplification methods, has become the most used method due to its simplicity. Microfluidic technologies enable the miniaturization of PCR processes on a chip with potential benefits such as speed, cost, portability, efficiency and automation. With the thesis study, the design and production of the microchip and micro temperature cycler required to perform PCR were carried out. For this purpose, Computer Aided Design (CAD) program was used in the microchip design, and a laser cutter, one of the CAD methods, was used in its production and a single-chamber chip was produced. The materials used in microchip production were coverslips, double-sided tape (DSA) and polymethylmethacrylate (PMMA) polymer. Peltier module was chosen as the heating element to be used in the production of micro temperature cycler. Microcontroller and H-Bridge modules were used to perform temperature control. Temperature cycler circuit analysis was first made in a simulation program and the PCR cycle could be performed. Then, appropriate elements were provided to implement this circuit. The modes of H bridge type drivers and the circuit mechanisms regarding how they are driven with a microcontroller have been studied. H-bridge driving (with the help of a microcontroller) has been tried with the pulse width modulation (PWM) technique, which is one of the motor driving techniques. Firstly, Peltier module temperature tests were carried out with the supplied elements. The PCR cycle was realized by combining the circuit elements whose suitability was tested with the PID control algorithm developed for temperature cycle control. A different CAD program was used to simulate heat transfer and fluid flow. This software is based on the finite-element method. It makes it easy to combine and solve partial differential equations from different fields of physics. Laminar flow was simulated within the microchip using the fluid flow module. Additionally, an attempt was made to simulate the heat transfer in chip materials by using the heat transfer module. The DNA sample was amplified with the designed micro temperature cycler at Kırıkkale University Faculty of Medicine, Department of Medical Biology. To test that the design performed PCR, the sample used on the temperature cycler was also amplified using a commercial temperature cycler and the results were then determined with an appropriate analysis method.

Benzer Tezler

  1. Synthesis of novel polymeric structures by the combination of step growth polymerization and post-polymerization modification

    Adım büyüme polimerizasyonu ve post-polimerleştirme modifikasyonu ile yeni polimer yapılarının sentezi

    ELİF BAYSAK

    Doktora

    İngilizce

    İngilizce

    2019

    Polimer Bilim ve Teknolojisiİstanbul Teknik Üniversitesi

    Polimer Bilim ve Teknolojisi Ana Bilim Dalı

    PROF. DR. GÜRKAN HIZAL

  2. Synthesis of proton exchange membrane by atrp and iniferter methods

    Atrp ve iniferter yolu ile iyonik iletkenliğe sahip polimer sentezi

    CÜNEYT ERDİNÇ TAŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Polimer Bilim ve Teknolojisiİstanbul Teknik Üniversitesi

    Polimer Bilim ve Teknolojisi Ana Bilim Dalı

    PROF. DR. METİN HAYRİ ACAR

  3. Siloksan oligomeri-[(NH4)Ce(NO3)6] redoks çifti ile başlatılmış poli (N-izopropilakrilamid)lerin ve poli(akrilamid)lerin sentezi ve karakterizasyonu

    Synthesis and characterization of poly(n-isopropyl acrylamid)s and poly(akrglimide)s initiated with siloxane oligomer-[(NH4)2Ce(NO3)6] redax pair

    HATİCE AKIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Kimyaİstanbul Teknik Üniversitesi

    DOÇ.DR. CANDAN ERBİL

  4. Tegomer H-Si 2111-Ce(IV) redoks çifti ile başlatılmış NIPAAM jelleri ve PNIPAAM/PVSi 2250 semi IPN'leri

    NIPAAM gels initiated by tegomer H-Si 2111 and PNIPAAM/PVSi 2250 semi IPN's

    EMİNE KAZANCIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Kimyaİstanbul Teknik Üniversitesi

    PROF.DR. CANDAN ERBİL

  5. New methodologies for macro and micro structured hyperbranched polymers

    Makro ve mikro yapılı çok dallanmış polimerler için yeni yöntemler

    SEMİRA BENER

    Doktora

    İngilizce

    İngilizce

    2021

    Kimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. YUSUF YAĞCI