Farklı endokron tasarımlarında bitim hattı ve kavite derinliğinin ağız içi tarayıcı hassasiyetine etkileri

Effects of finish line and cavity depth on intraoral scanner accuracy in different endocrown designs

  1. Tez No: 936593
  2. Yazar: SİMGE ALICI
  3. Danışmanlar: PROF. DR. SELİM ERKUT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Endokron, ağız içi tarayıcı, bitim hattı, kavite derinliği, hassasiyet, Endocrown, intraoral scanner, finish line, cavity depth, accuracy
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Başkent Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Ağız içi tarayıcılar kullanılarak elde edilen dijital ölçülerde farklı pulpal kavite derinliklerinin tarama hassasiyetini etkilediği rapor edilmiştir. Bununla birlikte, güncel ağız içi tarayıcılar ile endokron preparasyonlarında farklı kavite geometrilerinin dijital ölçü hassasiyetine etkisi ile ilgili çalışmalar yetersizdir. Bu in vitro çalışmanın amacı, farklı endokron tasarımları ve bitim hatlarının ağız içi tarayıcı hassasiyeti üzerindeki etkisini incelemektir. Bu amaçla, iki farklı kavite derinliği (2 mm ve 4 mm) ve üç farklı okluzal geometriye (servikal çizginin 2 mm okluzalinde shoulder, servikal çizginin 4 mm okluzalinde shoulder ve butt marjin) sahip altı adet prepare diş modeli oluşturuldu. Her grupta, laboratuvar tarayıcısı (Medit T310) ile elde edilen dijital veriler referans model olarak kullanıldı. Modeller dört farklı ağız içi tarayıcı (Trios 3, Medit i600, Helios 600, Trios 5) ile tarandı (n=10). Referans veriler ile ağız içi tarayıcılardan elde edilen dijital ölçü verileri best-fit programıyla çakıştırılarak ölçü hassasiyeti değerlendirildi. Verilerin istatistiksel analizinde SPSS (Versiyon 22, SPSS Inc, Chicago, IL, ABD) paket programı kullanıldı. Karşılaştırılan gruplar arasında varyansların homojenliği varsayımını sınamak için Levene testi kullanıldı. Normal dağılıma uyan ilişkili sayısal verilerin tarayıcılar arasında karşılaştırılması için Tekrarlı Ölçümlerde Varyans Analizi (ANOVA), normal dağılıma uymayan ilişkili sayısal verilerin tarayıcılar arasında karşılaştırılması için Friedman testi kullanıldı. İstatistiksel olarak anlamlı farklılık belirlenen Tekrarlı Ölçümlerde ANOVA ve Friedman testi sonrasında farklılığın hangi tarayıcılar arasında olduğunu belirlemek için Bonferroni düzeltmeli post-hoc ikişerli karşılaştırma testleri kullanıldı. Tüm analizler için istatistiksel anlamlılık düzeyi p<0.05 olarak kabul edildi. Tüm ağ ız iç i tarayıcılar iç in shoulder bitiş sınırına sahip modeller daha yüksek sapma değerleri gösterdi (p<0.05). 2 mm pulpal kavite derinliği ve 4 mm pulpal kavite derinliğine sahip modeller arasında istatistiksel olarak anlamlı fark bulunmadı (p=0,741). Tüm örnekler için klinik olarak kabul edilebilir hassasiyette dijital ölçüler elde edildi. Bu çalışma Başkent Üniversitesi Tıp ve Sağlık Bilimleri Araştırma Kurulu tarafından onaylanmış (Proje no: D-DA24/03) ve Başkent Üniversitesi Araştırma Fonunca desteklenmiştir.

Özet (Çeviri)

It has been reported that variations in pulpal cavity depth can influence the scanning accuracy of digital impressions obtained using intraoral scanners. However, current studies investigating the impact of different cavity geometries in endocrown preparations on digital impression accuracy with contemporary intraoral scanners remain limited. The aim of this in vitro study was to evaluate the effects of different endocrown designs and finish line configurations on the scanning accuracy of intraoral scanners. For this purpose, six prepared tooth models were fabricated with two different cavity depths (2 mm and 4 mm) and three different occlusal geometries (a shoulder finish line located 2 mm occlusal to the cervical line, a shoulder finish line located 4 mm occlusal to the cervical line, and a butt margin). In each group, digital data obtained with a laboratory scanner (Medit T310) were used as reference models. The models were scanned with four different intraoral scanners (Trios 3, Medit i600, Helios 600, and Trios 5) (n=10). The digital impressions obtained from the intraoral scanners were superimposed onto the reference data using a best-fit algorithm to assess scanning accuracy. For statistical analysis, SPSS software (Version 22, SPSS Inc, Chicago, IL, USA) was used. Levene's test was performed to assess the assumption of homogeneity of variances among the compared groups. Repeated measures analysis of variance (ANOVA) was used for normally distributed data, while the Friedman test was used for non-normally distributed related numerical data. Following the identification of statistically significant differences in ANOVA and Friedman tests, pairwise comparisons between scanners were conducted using Bonferroni-corrected post- hoc tests. The level of statistical significance was set at p<0.05 for all analyses. Models with shoulder finish lines demonstrated significantly higher deviation values across all intraoral scanners (p<0.05). No statistically significant difference was found between models with 2 mm and 4 mm pulpal cavity depths (p=0.741). For all samples, digital impressions within clinically acceptable accuracy limits were obtained. This study was approved by Baskent University Institutional Review Board (Project no: D-DA24/03) and supported by Baskent University Research Fund.

Benzer Tezler

  1. Investigation of microbial population in hybrid biofilm nitrification systems

    Hibrit biyofilm nitrifikasyon sistemlerinde mikrobiyal popülasyonun araştırılması

    PEGAH BAHRAMIAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2025

    İstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Hibrit seramik ve daimi reçine materyallerinden üretilen farklı restorasyon tasarımlarında stres dağılımının sonlu elemanlar analizi ile incelenmesi

    Finite element analysis of stress distribution indifferent restoration designs fabricated from hybridceramic and permanent resin materials

    EREN ÇAYIRLI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Bolu Abant İzzet Baysal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  3. Kök kanal tedavisi tamamlanmış dişlerde üç boyutlu baskı ve CAD-CAM sistemi ile üç farklı materyal kullanılarak üretilen endokronların klinik başarılarının araştırılması

    Investigation of the clinical outcomes of endocrowns manufactured from three different materials using 3D printing and CAD-CAM technology in teeth with completed root canal treatment

    MISTIK MUSTAFA KORKMAZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Ege Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  4. Açık apeksli üst çene ön dişlerde revitalizasyon tedavisi sonrası uygulanan indirekt restorasyonların kırılma dayanımı üzerine etkisinin karşılaştırılması: İn-vitro çalışma

    Comparison of the effect of indirect restorations on the fracture resistance of open-apex maxillary anterior teeth following revitalization therapy: An in-vitro study

    ALPEREN FAHRİ KEREMİT

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Ege Üniversitesi

    Endodonti Ana Bilim Dalı

    Yükleniyor...

  5. Farklı materyallerden üretilmiş endokron restorasyonlarda preparasyon geometrisinin uzun dönem başarıya etkisinin incelenmesi

    The assessment of preparation geometry on long term success in the endocrown restoration produced by different materials

    ESMA ÇAĞLAYAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Ondokuz Mayıs Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...