CHARACTERISING THE NOVEL TK101 EXTRACTION CHROMATOGRAPHY RESIN USING MULTI-ELEMENT TRACERS AND ICP-MS ANALYSIS
ÇOKLU ELEMENT İZLEYİCİLER VE ICP-MS ANALİZİ KULLANARAK YENİ TK101 EKSTRAKSİYON KROMATOGRAFİSİ REÇİNESİNİN KARAKTERİZASYONU
- Tez No: 942565
- Danışmanlar: DR. ELSJE VAN ES
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Nükleer Mühendislik, Çevre Mühendisliği, Chemistry, Nuclear Engineering, Environmental Engineering
- Anahtar Kelimeler: ICP-MS, Radyokimya, ICP-MS, Radiochemistry
- Yıl: 2019
- Dil: İngilizce
- Üniversite: The Unıversıty Of Bırmıngham
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Nükleer Bilimler Ana Bilim Dalı
- Bilim Dalı: Nükleer Bilimler Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Radyum, doğal olarak oluşan bir radyonükliddir ve ortamda radyum dörtlüsü (226,228,224,223Ra) olarak bulunur ve NORM endüstrilerinin işlenmesiyle konsantrasyonları artar. İçme suyundaki Ra'nın sınırlamaları konusunda katı öneriler ve düzenlemeler vardır çünkü Ra sulu ortamlarda iyi çözünebilir ve çeşitli yollarla insanlara ulaşabilir. 226Ra'nın ölçümü, örneklerden doğru veri sağlamak için gereken zaman ve maliyet açısından zahmetlidir çünkü çevresel örnekler düşük seviyede 226Ra ve bozunma sayımı veya kütle spektrometrik tekniklerle doğru ölçümü engelleyebilecek diğer önemli elementleri içerir. Bu zorluğun üstesinden gelmek için, 226Ra'nın belirlenmesinden önce ön konsantrasyon ve kimyasal ayırma uygulanmalıdır. Ancak bu teknikler, söz konusu ölçüm tekniklerinden kaynaklanan farklı girişimler nedeniyle yoğun ön işlemle radyometrik ve kütle spektrometrik teknikler gibi farklı ölçüm yöntemleri uygulandığından prosedürel süreyi ve analiz iş yükünü artırır. Ek olarak, kütle spektrometrik analizden önce numune ön koşullandırma ve hedef elementin diğer bileşenlerden ayrılması için ekstraksiyon kromatografi reçinesi kullanılması, içme suyu yönetmeliklerine ve önerilerine uymak için prosedürel zaman, doğruluk ve tespit limitlerinde iyileştirmeler sağlamıştır. Bu proje sırasında, Triskem International tarafından geliştirilen yeni bir ekstraksiyon kromatografi reçinesi olan TK101, 226Ra'nın ve potansiyel olarak karışan elementlerin reçine üzerindeki davranışını <24 saatte belirlemek için karakterize edildi. TK101 reçinesi üzerindeki elementlerin afinitelerini belirlemek için grup 1 ve 2 elementleri ile lantanitler, aktinitler, geçiş metalleri ve geçiş sonrası metaller için 0,01-10 M asit konsantrasyonunda HCl ve HNO3'teki dağılım katsayıları incelendi. Sonuçlar, 226Ra ölçümleri için pH 2'de su numunelerinin doğrudan yüklenmesinin mümkün olabileceğini göstermektedir. Ancak 226Ra, aynı asit konsantrasyonunda diğer karışan elementlerle (Ba,Sr vb.) birlikte TK101 reçinesi üzerinde iyi bir şekilde tutulmuştur; bu da Ra'nın Ba,Sr'dan ayrılmasının mümkün olmadığını göstermektedir.
Özet (Çeviri)
Radium is naturally occurring radionuclide exists as radium quartet(226,228,224,223Ra) in the environment increasing the concentrations by the processing of NORM industries. There are strict recommendations and regulations on the limitations of Ra in drinking water because Ra can be well dissolved in aqueous media and reach to humans through the several pathways. Measurement of 226Ra is cumbersome in terms of time and cost needed to provide accurate data from samples because environmental samples contain low-level of 226Ra, as well as other major elements that might prevent accurate measurement by decay counting or mass spectrometric techniques. To overcome this challenge, pre-concentration and chemical separation should be applied prior to the determination of 226Ra. These techniques, however, increase procedural time and work-load of analysis because different measurement methods such as radiometric and mass spectrometric techniques are applied with intensive pre-treatment due to different interferences resulting from measurement techniques in question. Additionally, using extraction chromatographic resin for sample preconditioning and separation of the target element from other components prior to mass spectrometric analysis has recently provided the improvements of procedural time,accuracy and detection limits so as to comply with drinking water regulations and recommendations. During this project, a novel extraction chromatography resin, TK101 developed by Triskem International, was characterised in order to determine the behaviour of 226Ra and potential interfering elements on the resin in <24 h. The distribution coefficients in HCl and HNO3 over the acid concentration of 0.01-10 M for group 1 and 2 elements as well as lanthanides, actinides, transition metals and post-transition metals were investigated to identify affinities of the elements on the TK101 resin. Results suggest that direct loading of water samples at pH 2 as to measurements of 226Ra may be possible. 226Ra was, however, well retained on the TK101 resin with other interfering elements(Ba,Sr etc.) at the same acid concentration, which indicates that the separation of Ra from Ba,Sr isn't achievable.
Benzer Tezler
- İçme suyu filtrelerinin geri yıkanmasında en uygun gözeneklilik tayini
Optimum porosity of granular water filters during backwashing
MUSTAFA TURAN
- Poli (para-klorastiren) zincirlerinin çeşitli çözücülerde geniş bir sıcaklık bölgesinde dipol momentleri ve intrinsik viskoziteleri
Dipole moments and intrinsic viscosities of poly (para-chlorostyrene) chains in various solvents over a wide range of temparature
FERDANE YILMAZ
- Demiryollarda ara istasyonların tesisi ile katar seyir sürelerinden elde edilebilen zaman tasarrufu fonksiyonlarının formüle edilmesi ve pratik sonuçları
Başlık çevirisi yok
MEHMET YAŞAR METE SÜMER