Geri Dön

Basınç sensörü kontrolünde cila sistemlerinin rezin kompozitin yüzey şekli, pürüzlülüğü, parlaklığı ve hacim kaybı üzerine etkisi

The effect of pressure-regulated polishing systems on surface topography, roughness, gloss, and volume loss of resin composites

  1. Tez No: 950125
  2. Yazar: EZGİ KIZIL ÖZTÜRK
  3. Danışmanlar: PROF. DR. CAFER TÜRKMEN
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Uygulama kuvveti, büyütme, cila sistemleri, pürüzlülük, boyutsal farklılık, parlaklık, Application force, magnification, polishing systems, roughness, dimensional change, gloss
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu in vitro çalışmada, cila prosedüründe klinisyen tecrübesi, büyütme kullanımı, uygulama kuvveti ve cila sistemlerinin; yüzey pürüzlülüğü, parlaklığı ve boyutsal farklılık üzerine etkileri karşılaştırmalı olarak değerlendirilmiştir. Gereç ve Yöntem: Çalışmada nanohibrit rezin kompozit olan Neo Spectra ST (Dentsply Sirona) A2 rengi kullanıldı. Bu rezin kompozitten anterior diş morfolojisine sahip hazır silikon kalıp kullanılarak aynı kalınlık ve boyutlarda 150 adet örnek hazırlandı. Örnekler, klinisyen tecrübesi ve uygulama kuvvetine göre üç ayrı gruba ayrıldı. İlk iki grupta kuvvet, tecrübeli ve tecrübesiz klinisyenler tarafından uygulanan kuvvet sabitlenmeden serbest olarak uygulandı; üçüncü grupta ise uygulama kuvveti ortalama 1 N olması hedeflenerek 0,8-1,2 N aralığında uygulandı. Uygulama sırasında kuvvet değerleri, basınç sensörlü ve kuvvet ayarlı bir fırçalama cihazı ile anlık olarak kaydedildi ve özel bir yazılım aracılığıyla dijital ortama aktarıldı. Tüm cila işlemleri büyütme kullanılarak ve kullanılmadan olmak üzere iki gözlem koşulunda gerçekleştirildi. Her koşulda beş farklı cila sistemi (n=5), aynı tip kompozit materyal üzerinde cilalandı. Bu gruplar; Sof-Lex Disk (3M ESPE, ABD), Enhance/PoGo (Dentsply Sirona, ABD), Lucida (DiaShine, Style İtaliona,ABD), Diacomp Twist Plus (EVE Ernst Vetter, Keltern, Almanya) ve Opti1Step (KavoKerr Corporation, ABD 3M, ABD) olarak belirlendi. Cila öncesi ve sonrası örneklerin profilometre ile yüzey pürüzlülüğü, glossmetre ile yüzey parlaklığı ölçüldü. Cila öncesi ve sonrası alınan taramalar Geomagic Control X programına aktarılarak iki veri arasındaki boyutsal farklılık değerlendirildi. Elde edilen veriler SPSS v23 (IBM) programı ile analiz edildi ve anlamlılık düzeyi p<0,05 olarak belirlendi. Bulgular: Uygulama kuvveti, Uygulama 2' de Uygulama 1 'e göre anlamlı derecede daha yüksek bulundu (p<0,001). Büyütme ve cila sistemi uygulama kuvveti üzerinde etkili bulundu (p<0,001). Yüzey pürüzlülüğü ve parlaklık üzerinde en belirleyici değişkenin kullanılan cila sistemi olduğu belirlendi, klinisyen tecrübesi ve büyütmenin etkisi istatistiksel olarak anlamlı bulunmadı (p>0,05). Cila sistemleri arasında, boyutsal farklılık değerleri açısından da anlamlı fark saptandı (p<0,001). Lucida cila sisteminin ortalama RMS değeri diğer tüm cila sistemlerinden anlamlı düzeyde farklıdır (p<0,05). Sonuç: Uygulama kuvveti; klinisyen tecrübesi, büyütme kullanımı ve cila sistemine bağlı olarak değişkenlik gösterdi. Yüzey özellikleri üzerinde en belirleyici etkenin cila sistemi olduğu, pürüzlülük ile parlaklık arasında ters yönlü bir ilişki bulunduğu görüldü. Kuvvet arttıkça boyutsal farklılığın arttığı saptandı.

Özet (Çeviri)

Objective: The present in vitro study was conducted with the objective of comparatively evaluating the effects of clinician experience, magnification use, application force and polishing systems on surface roughness, gloss and dimensional variation in the polishing procedure. Materials and Methods: The study utilised the Neo Spectra ST (Dentsply Sirona) A2 colour nanohybrid resin composite. A total of 150 samples of uniform thickness and size were prepared from the resin composite using a ready-made silicone mold with anterior tooth morphology. The samples were divided into three separate groups based on clinician experience and application force. In the first two groups, the application of force was executed without restraint by both experienced and inexperienced clinicians; in the third group, the application force was targeted to be an average of 1 N and applied within the range of 0.8–1.2 N. During the application process, force values were recorded in real-time using a pressure-sensing and forceadjustable brushing device and transferred to a digital format via specialized software. All polishing procedures were conducted under two observation conditions: with and without magnification. In each condition, five distinct polishing systems (n=5) were applied to the same type of composite material. The following groups were identified: Sof-Lex Disk (3M ESPE, USA), Enhance/PoGo (Dentsply Sirona, USA), Lucida (DiaShine, Style Italia, USA), Diacomp Twist Plus (EVE Ernst Vetter, Keltern, Germany), and Opti1Step (KavoKerr Corporation, USA 3M, USA). The surface roughness was measured using a profilometer, and the surface gloss was measured using a glossmeter before and after polishing. Subsequent to the polishing process, the scans were transferred to the Geomagic Control X program, and the dimensional discrepancies between the two sets of data were evaluated. The obtained data were analysed using SPSS v23 (IBM) software, with a significance level set at p<0.05. Results: The application force was significantly higher for Application 2 than for Application 1 (p < 0.001). Magnification and the polishing system were found to affect application force (p <0.001). The polishing system used was found to be the most significant variable affecting surface roughness and gloss; the effects of clinician experience and magnification were not statistically significant (p> 0.05). Significant differences were also detected between polishing systems in terms of dimensional difference values (p <0.001). The average RMS value of the Lucida polishing system differed significantly from the average values of all the other polishing systems (p <0.05). Conclusion: The application force varies depending on the experience of the clinician, the use of magnification and the polishing system. It has been observed that the polishing system has the greatest impact on surface properties and that there is an inverse relationship between roughness and gloss. It has also been determined that dimensional differences increase as force increases.

Benzer Tezler

  1. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    KardiyolojiGazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

  2. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. OĞUZ BORAT

  3. Posterior fossa tümörleri

    Başlık çevirisi yok

    SERHAT AYDINER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    NöroşirürjiGazi Üniversitesi

    Nöroşirürji Ana Bilim Dalı

  4. Türkiye'de serebral hareket bozukluklarının etiyolojisi epidemiyolojisi ve bazı klinik özellikleri

    Başlık çevirisi yok

    AŞER BENSUSAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Çocuk Sağlığı ve Hastalıklarıİstanbul Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

  5. Pulmoner hipertansiyon etyopatogenezinde prostasiklin ve lökotrien C4'ün rolü

    Possible role of leukotrien C4 and prostacyclin in the development of pulmonary hypertension

    ÜLKÜ AYBERK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Çocuk Sağlığı ve HastalıklarıGazi Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı