Geri Dön

Derin marjin elevasyonunda kullanılan farklı restoratif materyallerin CAD/CAM kuron restorasyonların kırılma dayanımına etkisi

The effect of different restorative materials used in deep margin elevation on the fracture resistance of CAD/CAM crown restorations

  1. Tez No: 957744
  2. Yazar: MUHAMMED SAİD ASLANLI
  3. Danışmanlar: PROF. DR. NİHAN GÖNÜLOL
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Derin marjin elevasyonu, CAD/CAM kuron, Kırılma dayanımı, Deep margin elevation, CAD/CAM crown, Fracture resistance
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Restoratif Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı, Derin Marjin Elevasyonu (DME) tekniğinde kullanılan farklı restoratif materyallerin CAD/CAM kuron restorasyonların kırılma dayanımına etkisini değerlendirmektir. Materyal-Metot: Bu in vitro çalışmada elli adet çekilmiş insan molar dişi kullanılmıştır. Örnekler beş gruba ayrılmıştır. Dört deney grubunda, sınıf II kaviteler açılarak kavitelerin gingival marjinleri mine-sement birleşiminin 2 mm apikaline konumlandırılmış ve ardından DME uygulanmıştır. DME uygulamasında Grup HF'de yüksek dolduruculu akışkan kompozit (GrandioSo Heavy Flow, VOCO, Cuxhaven, Almanya), Grup RM'de rezin modifiye cam iyonomer siman (Fuji II LC Capsule, GC, Tokyo, Japonya), Grup VB'de termovisköz bulk-fill kompozit (VisCalor Bulk, VOCO, Cuxhaven, Almanya) ve Grup NC'de CAD/CAM rezin bazlı blok materyal (Grandio blocs, VOCO, Cuxhaven, Almanya) kullanılmıştır. Kuron preparasyonu yapılarak preparasyon sınırları mine sement birleşiminin 1 mm koronalinde bitirilmiştir. Kontrol grubunda ise herhangi bir kavite açılmamış ve DME uygulanmamıştır. Tüm dişlerde CAD/CAM kuronlar üretilip simante edilmiştir. Örnekler 5000 termal döngüye tabi tutulmuş ve evrensel test cihazı ile kırılma dayanım testine alınmıştır. Ayrıca kırık tipleri değerlendirilmiştir. İstatistiksel analizde Two-way ANOVA ve Tukey çoklu karşılaştırma testi kullanılmıştır (p<0,05). Bulgular: En yüksek kırılma dayanımı Grup C'de (2093,0±220,6) gözlenmiştir, bunu Grup VB (1931,4±233,1) takip etmiştir. En düşük kırılma dayanımı ise Grup RM'de (1589,7±267,5) bulunmuştur. Hiçbir grupta katastrofik kırık oluşmamıştır. Sonuç: DME prosedüründe kullanılan restoratif materyal türü, CAD/CAM kuron restorasyonlarının kırılma dayanımını etkilemektedir.

Özet (Çeviri)

Aim: The aim of this study was to evaluate the effect of different restorative materials used in Deep Margin Elevation (DME) on the fracture resistance of CAD/CAM crown restorations. Material-Method: In this in vitro study, fifty extracted human molar teeth were used. The specimens were divided into five groups. In four experimental groups, Class II cavities were prepared, and the gingival margins of the cavities were positioned 2 mm apical to the cemento-enamel junction (CEJ); then, DME was applied. In Group HF, high-filler flowable composite (GrandioSo Heavy Flow, VOCO, Cuxhaven, Germany); in Group RM, resin-modified glass ionomer cement (Fuji II LC Capsule, GC, Tokyo, Japan); in Group VB, thermoviscous bulk-fill composite (VisCalor Bulk, VOCO, Cuxhaven, Germany); and in Group NC, CAD/CAM resin-based block material (Grandio blocs, VOCO, Cuxhaven, Germany) were used for DME. Crown preparations were made, and the preparation margins were finished 1 mm coronal to the CEJ. In the control group, no cavity was prepared and no DME was applied. CAD/CAM crowns were fabricated and cemented on all teeth. The specimens were subjected to 5000 thermal cycles and tested for fracture resistance using a universal testing machine. Fracture types were also evaluated. For statistical analysis, Twoway ANOVA and Tukey's post hoc test were used (p<0.05). Results: The highest fracture resistance was observed in Group C (2093.0±220.6), followed by Group VB (1931.4±233.1). The lowest fracture resistance was found in Group RM (1589.7±267.5). No catastrophic fractures occurred in any group. Conclusion: The restorative material used for DME influences the fracture resistance of CAD/CAM crowns.

Benzer Tezler

  1. Farklı derin marjin elevasyon yöntemlerinin cad/cam restorasyonların kırılma dayanım değerlerinin üzerine etkisi

    The effect of different deep margin elevation methods on the fracture strength values of cad/cam restorations

    ŞEYMA NİLGÜN BALCI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiKocaeli Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. NESLİHAN TEKÇE

  2. Değişik derim zamanı ve önsoğutmanın Bursa siyahı incir çeşidinin meyve kalitesi ve pazarlama süresi üzerine etkileri

    Effects of haruest time and precooling on fruit quality and shelf-life of the fig variety“Bursa siyahı”

    FÜSUN GÜRSEL ÇELİKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

  3. Tekstil boyamacılığında atık flottede boyama imkanları üzerine araştırma

    Başlık çevirisi yok

    MEHMET YAKARTEPE

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Tekstil ve Tekstil MühendisliğiEge Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. KERİM DURAN

  4. Ön işlemenin ve askorbik asitin dondurularak depolanan yılan balıklarının (Anguilla anguilla) kalitesine etkileri

    Başlık çevirisi yok

    H.VOLKAN GÖKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Su Ürünleri Ana Bilim Dalı

    DOÇ. DR. AYDIN URAL