Deniz ortaminin beton binalar üzerindeki etkisi: Libya Al-Zawiya Mühendislik Fakültesi örneği
Impact of marine environment on concrete buildings: Example of Libya Al-Zawiya College of Engineering
- Tez No: 961015
- Danışmanlar: PROF. DR. ENDER SARIFAKIOĞLU
- Tez Türü: Yüksek Lisans
- Konular: İnşaat Mühendisliği, Civil Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2025
- Dil: Türkçe
- Üniversite: Çankırı Karatekin Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 86
Özet
Bu çalışmanın amacı, Libya'daki Al-Zaviye Mühendislik Fakültesi'nin donatılı betonarme yapılarında, özellikle en fazla hasara uğramış olan idari binada gözlemlenen fiziksel ve kimyasal hasarların başlıca karbonatlaşma kaynaklı donatı korozyonunun nedenlerini ve etkilerini belirlemektir. Bölgesel iklim ve çevresel koşulların etkilerini de gözönünde tutularak, denizel çevreye maruz kalan betonarme yapılarda karbonatlaşma süreci ve donatı korozyonu değerlendirilmiştir. Deneysel çalışmalarda karbonatlaşma derinlikleri fenolftalein indikatör yöntemi ile belirlenmiş olup, betonun farklı bağıl nem, sıcaklık ve CO₂ konsantrasyonları altındaki dayanıklılığı incelenmiştir. Deneysel sonuçlar, karbonatlaşma derinliği ile beton basınç dayanımı arasında ters orantılı bir ilişki olduğunu ortaya koymuştur. Bazı kolonlarda karbonatlaşma derinliği 75 mm'ye kadar ulaşmıştır. Bu durum, pasif koruyucu tabakanın kaybolduğunu ve donatı korozyonu riskinin oluştuğunu işaret etmektedir. Klorür iyonu geçirimliliği, sınır değerlere yakın bulunmuştur. Yerinde yapılan geri tepme çekici ve ultrasonik darbe hızı testleri, beton dayanımının heterojen ve genellikle düşük olduğunu göstermiştir. Yapısal analizler, ETABS 2018 yazılımı ile gerçekleştirilmiş olup, döşemelerin taşıma kapasitelerinin yeterli olduğu, ancak B17 kodlu kiriş ve C22 kodlu kolon gibi bazı elemanların moment ve kesme dayanımlarının yetersiz olduğu belirlenmiştir. Sonuç olarak, mevcut yapı stokunda yaygın bir dayanım yetersizliği bulunmamakla birlikte, yerel zayıf halkaların yapının genel performansını olumsuz etkileyebileceği belirlenmiştir. Bu bağlamda, yetersiz elemanlar (B17 ve C22) için betonarme mantolama öngörülmektedir.
Özet (Çeviri)
The aim of this study is to determine the causes and effects of physical and chemical damages, especially carbonation-induced reinforcement corrosion, observed in the reinforced concrete structure of Al-Zawiya Engineering Faculty, Libya. Considering the effects of regional climate and environmental conditions, carbonation process and reinforcement corrosion in reinforced concrete structures exposed to marine environment were evaluated. In experimental studies, carbonation depths were determined by phenolphthalein indicator method and the durability of concrete under different relative humidity, temperature and CO₂ concentrations were examined. Experimental results revealed that there is an inversely proportional relationship between carbonation depth and concrete compressive strength. Carbonation depth reached up to 75 mm in some columns. This situation indicates that the passive protective layer is lost and there is a risk of reinforcement corrosion. Chloride ion permeability was found to be close to the limit values. On-site rebound hammer and ultrasonic pulse velocity tests showed that concrete strength was heterogeneous and generally low. Structural analyzes were performed with ETABS 2018 software and it was determined that the bearing capacities of the slabs were sufficient, but the moment and shear strengths of some elements such as B17 coded beam and C22 coded column were insufficient. As a result, although there is no widespread strength deficiency in the existing building stock, it has been determined that local weak links may negatively affect the overall performance of the structure. In this context, reinforced concrete sheathing is envisaged for the deficient elements (B17 and C22).
Benzer Tezler
- Arazi örtüsü - arazi kullanımı değişikliğinin yer yüzey sıcaklığına etkisinin landsat görüntüleri ve Google earth engine platformu kullanımıyla uzun vadeli izlenmesi
Investigation of the effect of land cover/ land use change on surface temperature using landsat satellite imagery assistance and Google earth engine platform
ESRA ŞENGÜN
Yüksek Lisans
Türkçe
2022
Jeodezi ve Fotogrametriİstanbul Teknik ÜniversitesiGeomatik Mühendisliği Ana Bilim Dalı
DOÇ. DR. UĞUR ALGANCI
- Influence of powder and emulsion polymer addition on strength and capillary properties of cement mortars
Toz ve emülsyon polimer katkılarının çimentolu harçların dayanım ve kılcallık özelliklerine etkisi
ZEHRA KÖKMEN
Yüksek Lisans
İngilizce
2018
Polimer Bilim ve Teknolojisiİstanbul Teknik ÜniversitesiPolimer Bilim ve Teknolojisi Ana Bilim Dalı
PROF. DR. MUSTAFA HULUSİ ÖZKUL
- 2007 Türk Deprem Yönetmeliği ve İstanbul Yüksek Binalar Deprem Yönetmeliğine göre yüksek bir binanın tasarımı
Analysis of a high-rise reinforced concrete building according to 2007 Turkish Earthquake Code and Istanbul High-Rise Buildings Earthquake Regulations
ERSİN DENİZ ÇINAR
Yüksek Lisans
Türkçe
2015
Deprem Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DOÇ. DR. ABDULLAH NECMETTİN GÜNDÜZ
- Karma llif içeren çimento esaslı kompozitlerin mekanik davranışı - bir optimum tasarım
Mechanical behavior of cement based composites reinforced with hybrid fibres - an optimum design
ÖZGÜR EKİNCİOĞLU
Yüksek Lisans
Türkçe
2003
İnşaat Mühendisliğiİstanbul Teknik ÜniversitesiYapı Malzemesi Ana Bilim Dalı
DOÇ. DR. CANAN TAŞDEMİR
- Kendiliğinden yerleşen betonun reolojik özelliklerine bileşim parametrelerinin etkisi
Effects of component parameters on rheological properties of self compacting concrete
ALİ RAİF SAĞLAM
Doktora
Türkçe
2003
İnşaat Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. HULUSİ ÖZKUL