Geri Dön

Examination of machine learning based image enhancement model on OCTA retina images

OKTA retina görüntüleri üzerinde makine öğrenmesi tabanlı görüntü iyileştirme modelinin incelenmesi

  1. Tez No: 964267
  2. Yazar: BERFİN DİNÇ
  3. Danışmanlar: DOÇ. DR. SERHAT TOZBURUN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrol, Göz Hastalıkları, Computer Engineering and Computer Science and Control, Eye Diseases
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: İngilizce
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: İzmir Uluslararası Biyotıp ve Genom Enstitüsü
  11. Ana Bilim Dalı: Biyotıp ve Sağlık Teknolojileri Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Retina yapılarının yüksek çözünürlüklü (HR) görüntülemesi, optik koherens tomografi (OCT) ve OCT anjiyografisi (OCTA) kullanılarak elde edilebilir; ancak ham 6×6 mm geniş alan taramaları, ham 3×3 mm taramalardan daha düşük mekansal çözünürlüğe sahiptir. Bu tez, Döngü Tutarlı Çekişmeli Ağlar (CycleGAN) ve modifiye edilmiş Gelişmiş Derin Süper Çözünürlük (EDSR) ağını kullanarak 6×6 mm OCT ve OCTA görüntülerinin çözünürlüğünü artırmak için iki aşamalı bir derin öğrenme yöntemi önermektedir. Hata fonksiyonu olarak Yapısal Benzerlik İndeksi Ölçümü (SSIM) kullanılarak modifiye edilmiş EDSR modeli eğitilmek üzere bikübik aşağı örneklenmiş 3×3 mm OCT görüntüleri kullanılmıştır. Daha sonra modeli OCTA'ya uyarlamak için Transfer Öğrenme (TL) kullanılmıştır. Eşleştirilmemiş eğitimi yönetmek için ham 6×6 mm görüntüleri bikübik aşağı örneklenmiş 3×3 mm benzeri bir alana eşlemek için CycleGAN kullanılmıştır. Tam referans metrikleri için 3×3 mm OCT taramalarını temel gerçeklik olarak kullanarak, önerilen EDSR PSNR'yi 28,26 dB'den 29,59 dB'ye ve SSIM'yi 0,7695'ten 0,8776'ya çıkardı. Transfer öğrenme, OCTA'da PSNR'yi 21,58'den 23,50 dB'ye ve SSIM'yi 0,6449'dan 0,8500'e yükseltti. Referanssız kalite değerlendirmeleriyle gösterildiği gibi, ham 6×6 mm OCT görüntüleri ile CycleGAN tarafından oluşturulan çıktılar arasında önemli iyileştirmeler gösterildi. CLIP-IQA 0,4389'dan 0,3352'ye (GT 3×3 mm 0,3244) ve BRISQUE 45,40'tan 40,52'ye (GT 3×3 mm 43,34) düştü. TV, OCTA'da 54,22'den 100,93'e yükseldi (GT 3×3 mm 98,96). Sonuçlar, CycleGAN + modifiye edilmiş EDSR modellerinin görsel kaliteyi önemli ölçüde iyileştirdiğini, ancak TV ve CLIP-IQA gibi bazı referanssız puanların gerçek kalite seviyelerinin biraz altında kaldığını göstermektedir. Önerilen teknik, geniş alanlı retina görüntülemede daha yüksek çözünürlüklü görselleştirme sağlayarak ham 6×6 mm OCT/OCTA taramalarının yapısal netliğini ve olası tanı doğruluğunu artırmaktadır.

Özet (Çeviri)

High-resolution (HR) imaging of retinal structures can be obtained using optical coherence tomography (OCT) and OCT angiography (OCTA); however, raw 6×6 mm wide-field scans have lower spatial resolution than raw 3×3 mm scans. This thesis proposes a two-stage deep learning method to enhance the resolution of raw 6×6 mm OCT and OCTA images, utilizing Cycle-Consistent Adversarial Networks (CycleGAN) and a modified Enhanced Deep Super Resolution (EDSR) network. Bicubic down-sampled 3×3 mm OCT images were used to train the modified EDSR model, utilizing the Structural Similarity Index Measure (SSIM) as the loss function. Transfer learning (TL) was then used to adapt the model to OCTA. CycleGAN was utilized to map cropped 3×3 mm parts from raw 6×6 mm (cropped 3×3 mm) images into a bicubic down-sampled 3×3 mm-like domain to handle unpaired training. Using raw 3×3 mm OCT scans as ground truth for full-reference metrics, the proposed EDSR increased the PSNR from 28.26 dB to 29.59 dB and the SSIM from 0.7695 to 0.8776. TL raised PSNR from 21.58 to 23.50 dB and SSIM from 0.6449 to 0.8500 in OCTA. Significant improvements were demonstrated between cropped 3×3 mm OCT images and CycleGAN-generated outputs, as shown through no-reference quality evaluations. CLIP-IQA decreased from 0.4389 to 0.3352 (GT 3×3 mm 0.3244), and BRISQUE decreased from 45.40 to 40.52 (GT 3×3 mm 43.34). TV increased from 54.22 to 100.93 in OCTA (GT 3×3 mm 98.96). The results show that CycleGAN + modified EDSR models significantly improve visual quality, although some no-reference scores such as TV and CLIP-IQA remained slightly below ground truth quality levels. The suggested technique improves the structural clarity and possible diagnostic accuracy of raw 6×6 mm OCT/OCTA scans by enabling higher-resolution visualization in wide-field retinal imaging.

Benzer Tezler

  1. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. Pre-eklampsi ve eklampsi vakalarında immünoglobülin düzeylerinin değerlendirilmesi (Klinik ve immünobiolojik araştırma)

    Examination des valeurs d'immunoglobulines en cas de la toxemie gravidique

    M. MURAT SEMİZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  3. İsmayıl Hakkı Baltacıoğlu'nun kültür ve eğitim kavramı üzerine bir inceleme

    An Examination of the concepts of culture and education of Ismayıl Hakkı Baltacıoğlu

    ABDULLAH DİKİCİ

    Doktora

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Eğitim Bilimleri Ana Bilim Dalı

    Yükleniyor...

  4. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gata

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...