İmplant üstü protezlerde implant seviyesi ve dayanak seviyesi dijital ölçülerin karşılaştırılması

Comparison of digital measurements of implant level and autumn level in implant-supported prostheses

  1. Tez No: 971916
  2. Yazar: SERRA KÜÇÜKKILIÇ GÜNDÜZ
  3. Danışmanlar: PROF. DR. ALİ MURAT KÖKAT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dijital ölçü, implant seviyesi, dayanak seviyesi, gerçeklik, hassasiyet, tarama bayrağı, Digital impression, implant level, abutment level, trueness, precision, scanbody
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, implant üstü sabit protez planlamasında kullanılan dijital ölçülerin gerçekliğini ve hassasiyetini değerlendirmek amacıyla, farklı ağız içi tarayıcılarla alınan implant seviyesi ve dayanak seviyesi ölçülerin karşılaştırılmasıdır. Çalışmada, Dentsply Sirona Primescan, 3Shape TRIOS 4 ve 5, Itero Lumina ve Straumann Sirios marka beş farklı ağız içi tarayıcı kullanılmıştır. Dijital ölçülerin doğruluğunu karşılaştırmak amacıyla geçmişteki bir hastanın implant ve dayanak seviyesinde alınmış datalarından eş zamanlı olarak 3 boyutlu yazıcılarla iki adet parsiyel model üretilmiştir. Modellerden birinde implant seviyesi tarama bayrağı kullanılırken diğerinde dayanak seviyesi tarama bayrağı kullanılmıştır. Tüm taramalar STL formatında alınmış ve Geomagic Control X yazılımı kullanılarak endüstriyel tarayıcı referansı ile karşılaştırılmıştır. Elde edilen veriler, üç ana kategori altında değerlendirilmiştir: (1) tarama bayrağı RMS sapmaları, (2) tarama bayrağı 3B ve açısal sapmaları ve (3) implantlar arası doğrusal ve açısal deviasyonlar. Gerçeklik (trueness) ve hassasiyet (precision) açısından değerlendirilen bulgulara göre, genel olarak dayanak seviyesi ölçülerin doğruluğu ve hassasiyetinin implant seviyesine kıyasla daha yüksek olduğu tespit edilmiştir. Tarayıcıların ise farklı durumlarda öne çıkan özellikleri olmuştur. Sonuç olarak, dijital ölçülerin doğruluğu hem ölçü seviyesine hem de kullanılan ağız içi tarayıcıya göre anlamlı şekilde değişmektedir. Bu bulgular, dijital implant ölçü protokolünün planlanmasında klinisyenler için önemli bir rehber sunmaktadır.

Özet (Çeviri)

The aim of this study is to compare the trueness and precision of implant-level and abutment-level digital impressions obtained with different intraoral scanners, within the scope of digital impression techniques used in the planning of implant-supported fixed prostheses. Five different intraoral scanners were used in the study: Dentsply Sirona Primescan, 3Shape TRIOS 4 and 5, Itero Lumina, and Straumann Sirios. To evaluate the accuracy of digital impressions, two partial models were simultaneously fabricated using 3D printing technology from previously recorded data of a patient at both implant and abutment levels. One model included implant-level scan bodies, while the other included abutment-level scan bodies. All scans were obtained in STL format and compared to a reference obtained with an industrial scanner using Geomagic Control X software. The data were evaluated under three main categories: (1) scanbodie RMS deviations, (2) 3D and angular deviations of the scanbodies and (3) inter-implant linear and angular deviations. Based on assessments of trueness and precision, it was generally found that abutment level surface scans demonstrated higher accuracy and precision compared to implant level surface scans. However, each scanner exhibited different strengths depending on the clinical scenario. In conclusion, the accuracy of digital impressions varies significantly depending on both the impression level and the intraoral scanner used. These findings offer valuable guidance for clinicians when planning digital implant impression protocols.

Benzer Tezler

  1. Kobaylarda splenik ototransplantasyon ve postsplenektomi sepsisi

    Başlık çevirisi yok

    S.ÇAĞATAY ÇİFTER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  2. Saleplerin tohumla üretilmeleri

    Başlık çevirisi yok

    NURGÜL SÜBEROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    Yükleniyor...

  3. Filtre edilebilme sayısı ile filtrasyon optimum dozunun araştırılması

    Başlık çevirisi yok

    HULUSİ ÇOKADAR

    Doktora

    Türkçe

    Türkçe

    1984

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  4. Transformatör sargılarında oluşan hızlı değişimli geçici olayların incelenmesi ve enerji iletim sistemlerinin modellenmesinde yeni bir yaklaşım

    Investigation of high speed transients on transformer windings and a new approach in modelling of energy transmission systems

    A.OĞUZ SOYSAL

    Doktora

    Türkçe

    Türkçe

    1985

    İstanbul Teknik Üniversitesi

    Yükleniyor...