İklimlendirme sistemlerinin iç hava kalitesine ve havadan bulaşan hastalıkların yayılımına etkisi

The effect of air conditioning systems on indoor air quality and the spread of airborne diseases

  1. Tez No: 974376
  2. Yazar: ERGÜN BOZKURT
  3. Danışmanlar: DOÇ. DR. FARUK ORAL, DOÇ. DR. BAHADIR ERMAN YÜCE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mühendislik Bilimleri, Makine Mühendisliği, Engineering Sciences, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Bitlis Eren Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışma Bitlis Eren Üniversitesi Mühendislik ve Mimarlık Fakültesi Makine Mühendisliği İklimlendirme Laboratuvarında gerçekleştirilmiştir. Laboratuvar'da bulunan split tip klimanın belirli aralıklardaki üfleme açısı, hızı ve sıcaklığı ele alınarak bu parametrelere bağlı olarak ısıl konfor, cereyan ve izleyici gaz konsantrasyonu Hesaplamalı Akışkanlar Dinamiği (HAD) metodu ile incelenmiştir. Ofis tipi olan odada bir adet duvar tipi split klima, bir adet masa, bir adet dolap ve deney düzeneği mevcuttur. Odada bulunan duvar tipi klima üç modda çalışırken üfleme menfezinden çıkan havanın hız değerleri ölçülmüş ve elde edilen veri hem deneysel çalışmada hem de HAD analizinde referans veri olarak kullanılmıştır. Üç boyutlu olarak yapılan sayısal çalışmada akış sürekli, sıkıştırılamaz ve türbülanslı olarak ele alınmış ve yazılım olarak da Ansys Fluent 2023R2 kullanılmıştır. Odadaki hava ısınmadan dolayı yoğunluk farkı nedeniyle yer değişikliğine uğrayacağından Bousinesq yaklaşımı baz alınmıştır. Reynolds Ortalamalı Navier-Stokes denklemleri (RANS) tabanlı Realizable k-ε türbülans modeli seçilmiş olup duvar fonksiyonlarından Scalable Wall Function seçilmiştir. Sıcaklık ve hız verileri üzerinden akış sonucu oda içinde oluşan cereyan verileri ve gaz konsantrasyonu elde edilmiştir. HAD analizi sonucu elde edilen veriler, deney düzeneğindeki sensörlerce okunan aynı veriler ile kıyaslanmıştır.

Özet (Çeviri)

This study was carried out in the Mechanical Engineering Air Conditioning Laboratory of the Faculty of Engineering and Architecture of Bitlis Eren University. The blowing angle, velocity and temperature of the split type air conditioner in the laboratory were taken into consideration at certain intervals and the thermal comfort, draft and tracer gas concentration were investigated by the Computational Fluid Dynamics (CFD) method. There is one wall-type split air conditioner, one table, one cabinet and an experimental setup in the office type room. While the wall-type air conditioner in the room was operating in three modes, the velocity values of the air coming out of the blowing nozzle were measured and the obtained data were used as reference data both in the experimental study and in the CFD analysis. In the three-dimensional numerical study, the flow was considered as continuous, incompressible and turbulent and Ansys Fluent 2023R2 was used as the software. Since the air in the room will undergo a displacement due to the density difference due to heating, the Bousinesq approach was taken as basis. The Realizable k-ε turbulence model based on Reynolds Averaged Navier-Stokes equations (RANS) was selected and the Scalable Wall Function was also selected from the wall functions as well. In the experimental study, thermal comfort indexes and gas concentration were obtained with sensors placed on the experimental setup and compared with the same data obtained by CFD analysis.

Benzer Tezler

  1. Buharlaştırıcıda yoğuşmanın analitik ve sayısal modellenmesi

    Analytical and numerical modelling of condensation in evaporator

    MELİH MERİÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. KADİR KIRKKÖPRÜ

  2. Metro istasyon ve tünellerinde havalandırma performansının enerji tüketimine etkilerinin incelenmesi

    Investigation of the effects of ventilation performance on energy consumption in subway stations and tunnels

    YAREN GÜVEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    EnerjiGazi Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    PROF. DR. MUSTAFA AKTAŞ

  3. Pasif havalandırma tasarımında geleneksel mimari yöntemlerinin kullanımı ve mevcut eğitim binalarında iç mekan hava optimizasyonu için bir yöntem

    Passive ventilation design using vernacular architecture methods and optimizing indoor air in existing educational buildings

    SAHAR TOHIDI

    Doktora

    Türkçe

    Türkçe

    2022

    MimarlıkGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    DOÇ. DR. DOÇ.Dr. MEHMET TAYFUN YILDIRIM

  4. Havalandırma kanalı ve yolcu kabini içindeki hava ve termal dağılımın HAD kullanılarak araştırılması

    Investigation of air and thermal distrubition in ventilation duct and passanger cabin using CFD

    ZEKİ TUĞBERK KARASU

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. LEVENT ALİ KAVURMACIOĞLU

  5. Sayısal görüntü işleme ve yapay zeka yöntemi ile son kullanıcı odaklı endüstriyel ürün tasarımı

    Industrial product design for end user with digital image processing and artificial intelligence method

    ATAHAN UYANIK

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolManisa Celal Bayar Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÖMER AYDIN