Taban yalıtımlı betonarme binalarda hedef periyot ve sönüm oranlarının davranışa etkilerinin incelenmesi

Investigation of the effects of target period and damping ratios on the behavior of base-isolated reinforced concrete buildings

  1. Tez No: 991965
  2. Yazar: ATA BEKTAŞ TÜRK
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ZEHRA ŞULE GARİP
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Karabük Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, ankastre mesnetli betonarme bina modelleri ile taban yalıtımlı (izolatörlü) betonarme bina modellerinin dinamik davranışları incelenmiştir. Binalar, ZA ve ZC olmak üzere iki zemin sınıfı kullanılarak tasarlanmıştır. İki farklı ankastre mesnetli bina modeli oluşturuldu. İlk ankastre mesnetli bina modelinde parametre olarak TBDY 2018 kriterlerine uygun R ve D değerleri sırasıyla 8 ve 3, diğer bina modelinde ise taban yalıtımlı sistemlerle kıyaslama yapabilmek için R ve D değerleri 1.5 alınmıştır. Taban yalıtımlı bina modellerinde farklı parametreler dikkate alınmıştır. Tüm bina modelleri 5 ve 10 katlı olarak tasarlanmış ve bina kat sayısının, hedef periyodun, sönüm oranının ankastre mesnetli ve izolatörlü olma durumlarında davranışa etkileri incelenmiştir. İzolatörlü 5 katlı bina modellerinde hedef periyotlar 1, 1.5 ve 2, 10 katlı modellerde ise 2, 3 ve 4 olarak dikkate alınmıştır. Kat sayısının artması, periyot değerlerinde artışa neden olacağından farklı hedef periyot değerleri incelenmiştir. Tüm izolatörlü bina modellerinde %10, %15 ve %20 olmak üzere 3 farklı sönüm oranı kullanılmıştır. İzolatör sisteminde kullanılan farklı sönüm oranlarının bina davranışına etkileri belirlenmiştir. Tüm bu parametreler dikkate alındığında 8 adet ankastre mesnetli bina modeli ve 24 adet izolatörlü bina modeli olmak üzere toplamda 32 adet bina modeli tasarlanmış ve mod birleştirme yöntemi ile dinamik analizleri PROTASTRUCTURE bilgisayar paket program ile gerçekleştirilmiştir. Analizler sonucunda elde edilen göreli kat öteleme değerleri, mod şekilleri, taban kesme kuvvetleri, katlara etkiyen deprem kuvvetleri şekiller ve çizelgeler halinde sunularak değerlendirilmiştir. Genel olarak bakıldığında izolatörlü sistemlerde deprem etkisi ankastre mesnetli binalar ile kıyaslandığında, yatay yer değiştirmeler büyük ölçüde izolatör katmanında toplanmış ve üst yapıdaki göreli kat ötelemeleri belirgin biçimde sınırlanmıştır. İzolatör karakteristik parametrelerinden olan hedef periyot ve sönüm oranı incelendiğinde, hedef periyot değerlerinin artması ile bina daha fazla yer değiştirme yapmakta ancak sönüm oranının artması ile bina daha kontrollü hale geldiğinden daha az yer değiştirme yapmaktadır. Bu durum hedef periyot değerinin üst yapı davranışını etkileyen ana parametrelerden olduğunu, sönüm oranının ise hedef periyottan kaynaklanan bu davranışı kontrol etmeye yarayan tamamlayıcı parametrelerden olduğunu göstermiştir.

Özet (Çeviri)

This study investigates the dynamic behavior of fixed-support reinforced concrete building models and base-isolated (insulated) reinforced concrete building models. The buildings were designed using two soil classes: ZA and ZC. Two different fixed-support building models were created. In the first fixed-support building model, R and D values were taken as 8 and 3, respectively, in accordance with the TBDY 2018 criteria, while in the other building model, R and D values were taken as 1.5 to allow comparison with base-isolated systems. Different parameters were considered in the base-isolated building models. All building models were designed as 5 and 10-story structures, and the effects of the number of stories, target period, and damping ratio on the behavior were investigated in fixed-support and isolator configurations. In the isolator-equipped 5-story building models, target periods were considered as 1, 1.5, and 2, while in the 10-story models, they were considered as 2, 3, and 4. Since increasing the number of stories leads to an increase in period values, different target period values were examined. Three different damping ratios of 10%, 15%, and 20% were used in all isolated building models. The effects of different damping ratios used in the isolator system on building behavior were determined. Considering all these parameters, a total of 32 building models were designed, including 8 fixed-beam building models and 24 isolator building models, and dynamic analyses were performed using the mode combination method with the PROTASTRUCTURE computer package program. The relative story displacement values, mode shapes, base shear forces, and seismic forces acting on the stories obtained from the analyses were presented and evaluated in figures and tables. Generally, when compared to fixed-beam buildings, isolator systems significantly concentrate horizontal displacements in the isolator layer and limit relative story displacements in the superstructure. When examining the target period and damping ratio, which are characteristic parameters of the isolator, it is observed that as the target period values increase, the building undergoes greater displacement, but as the damping ratio increases, the building becomes more controlled and undergoes less displacement. This shows that the target period value is one of the main parameters affecting the behavior of the superstructure, while the damping ratio is a complementary parameter that helps control this behavior caused by the target period.

Benzer Tezler

  1. Resilient design of CLT buildings against fire and earthquake

    Çok katlı CLT binaların yangın ve depreme karşı direnç esaslı tasarımı

    ÖMER ASIM ŞİŞMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    Deprem Mühendisliğiİstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ÖMER TUĞRUL TURAN

    PROF. DR. ARIO CECCOTTI

  2. The effect of horizontal irregularities and base isolation configuration on seismic response of rc buildings

    Yatay düzensizliklerin ve izolatör konfigürasyonunun taban yalıtımlı betonarme binaların deprem davranışına etkisi

    EYLEM BİLGE YAZICIOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    Deprem MühendisliğiOrta Doğu Teknik Üniversitesi

    Deprem Çalışmaları Ana Bilim Dalı

    PROF. DR. ALP CANER

    PROF. DR. MURAT DİCLELİ

  3. Sismik yalıtımlı yapılarda patlama etkilerinin incelenmesi

    Investigation of blast effects in seismic isolated buildings

    ELİF TOPLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    İnşaat MühendisliğiSakarya Uygulamalı Bilimler Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ OSMAN KIRTEL

  4. Çapraz yay gruplarını kullanan sismik yalıtım sistemi etkinliğinin uygulamada yaygın olarak kullanılan diğer sistemler ile karşılaştırılması

    Comparison the effectiveness of seismic isolation system made of spring tube braces with the systems commonly used in practice

    MUHAMMED ŞÜKRÜ YAVAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    Deprem Mühendisliği Ana Bilim Dalı

    PROF. DR. ERCAN YÜKSEL

  5. Yerel zemin koşullarının sismik izolasyonlu binaların performansına etkisi

    Effects of local soil conditions on the performance of seismically isolated buildings

    ADEM TEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    İnşaat Mühendisliğiİstanbul Üniversitesi-Cerrahpaşa

    İnşaat Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SEDA ÖNCÜ DAVAS

    DR. SİNAN SARĞIN