Farklı abutment sistemlerinin biyomekanik stres ve implant komponentlerinin dayanımı üzerindeki etkilerinin sonlu elemanlar analizi ile incelenmesi

Finite element analysis of the effects of different abutment systems on biomechanical stress and implant components

  1. Tez No: 1000519
  2. Yazar: İLAYDA TUNÇ BOTELLO BECERRA
  3. Danışmanlar: DOÇ. DR. BAHATTİN ALPER GÜLTEKİN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: abutment, açılı, dental implant, mikro boşluk, simansız, sonlu elemanlar analizi, abutment, angulated, cementless, dental implant, finite element analysis, microgap
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Oral İmplantoloji Ana Bilim Dalı
  12. Bilim Dalı: Oral İmplantoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Tunç Botello Becerra, İ. (2026). Farklı Abutment Sistemlerinin Biyomekanik Stres ve İmplant Komponentlerinin Dayanımı Üzerindeki Etkilerinin Sonlu Elemanlar Analizi İle İncelenmesi. İstanbul Üniversitesi Sağlık Bilimleri Enstitüsü, Oral İmplantoloji ABD. Doktora Tezi. İstanbul. Bu çalışma, farklı retansiyona sahip üç farklı abutment sisteminin biyomekanik davranışı ve implant-abutment arayüzündeki mikro boşluk paternine etkisini karşılaştırmalı olarak değerlendirmeyi amaçlamıştır. Bu kapsamda, Sonlu Elemanlar Analizi yöntemi ile geleneksel siman bağlantılı abutment, multiunit abutment ve yenilikçi simansız link tutuculu abutment sistemleri kullanılarak maksiller üç üye restorasyonlar oluşturulmuştur. Dental implantlar 0°/0°, 0°/15°, 0°/25°, 15°/15°, 25°/25° açı kombinasyonlarında yerleştirilerek toplam 400 N vertikal ve 45° açı ile 200 N oblique yükleme altında analizler yapılmıştır. Her iki yükleme altında, implant ve abutmentlarda görülen stres değerlerinin yenilikçi link tutuculu abutment sisteminde daha düşük olduğu, geleneksel siman bağlantılı abutment sisteminde ise en yüksek stres değerlerinin gözlendiği görülmüştür. Buna karşın, oblik yükleme altında peri-implanter kemikte oluşan maksimum ve minimum asal gerilmeler link abutment sisteminde en yüksek değerleri vermiştir. Mikro boşluk formasyonu her iki yükleme altında molar bölgede premolar bölgeye oranla daha yüksek değerler ile ilişkilendirilmekle birlikte farklı yükleme ve açılandırma koşulları altında sistemler arasında bir grup belirgin olarak öne çıkmamıştır. Bununla birlikte, açı artışı genel olarak tüm parametrelerde stres değerlerinin artışına neden olmuştur. Eğimli implantlarda multiunit abutment ve link abutment sistemlerinin siman bağlantılı sisteme göre daha avantajlı sonuçlar verdiği gözlenmiştir. Sonuçlar, yenilikçi simansız link abutment sisteminin, konvansiyonel siman bağlantılı ve multiunit abutment sistemlerine alternatif olarak kullanabileceğini ve özellikle siman bağlantılı abutment sistemine kıyasla belirlenen parametreler altında üstün biyomekanik performans sergilediğini göstermektedir.

Özet (Çeviri)

Tunç Botello Becerra, İ. (2006). Finite Element Analysis of the Effects of Different Abutment Systems on Biomechanical Stress and Implant Components. Istanbul University, Institute of Health Science, Department of Oral Implantology. PhD Thesis. Istanbul. This study aimed to analyze the biomechanics of three abutment systems with distinct retention mechanisms and their impact on the implant–abutment interface. The finite element analysis method was used to model maxillary three-unit restorations with conventional cement-retained abutment, multi-unit abutment, and innovative cementless link-retained abutment systems. Dental implants were positioned at 0°/0°, 0°/15°, 0°/25°, 15°/15°, and 25°/25° angulation combinations. Analyses were performed under 400 N vertical and 200 N oblique loading applied at a 45° angulation. The link-retained abutment system exhibited lower stress on the implants and abutments under both loading conditions, whereas the cement-retained abutment system demonstrated the highest stress. In contrast, the maximum and minimum principal stresses within the peri-implant bone were the highest in the link-retained system under oblique loading conditions. Despite greater microgap formation in the molar region, no specific abutment system exhibited a distinct superiority under different scenarios. Overall, an increase in implant angulation led to higher stress values across all parameters. The multi-unit and link abutment systems demonstrated reduced stress concentration and more uniform load distribution compared with the cement-retained system under tilted implant configurations. The findings suggest that the innovative cementless link-retained abutment system may serve as a feasible alternative to conventional cement-retained and multi-unit abutment systems, exhibiting superior biomechanical performance under specific conditions, particularly compared with the cement-retained abutment system.

Benzer Tezler

  1. İmplant-diş destekli sabit protetik tedavilerin farklı kemik dansitelerinde, farklı bağlantı seçeneklerinin 3 boyutlu sonlu elemanlar stres analiziyle incelenmesi

    A 3D finite element stress analysis of rigid and non-rigidconnector designs in implant–tooth supported fixed prostheses under different bone densities

    EMRE SİYABEND KONYAR

    Doktora

    Türkçe

    Türkçe

    2025

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. CEYDA AKIN

  2. Diş implantının biyomekanik davranışınınsonlu elemanlar metoduyla modellenmesi ve analizi

    Finite element modeling and analysis of the biomechanical behavior of a dental implant

    ROZELİN ERDEMLİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Biyomühendislikİstanbul Yeni Yüzyıl Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ DİYADİN CAN

  3. Farklı tip ve ağırlıktaki altyapı materyalleri ile oluşturulan implant üstü protezlerin kuvvet altında implant, abutment, vida, protez ve kemikte oluşturduğu stres dağılımının sonlu elemanlar stres analiz yöntemiyle incelenmesi

    Investigation of stress distribution on implant, abutment, screw, prosthesis and bone under force by finite element stress analysis method of implant supported prostheses created with framework materials of different types and weight

    OĞUZHAN GÖMLEKSİZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SUBUTAY HAN ALTINTAŞ

  4. Diş-implant destekli sabit protezlerde konnektör tipinin ve farklı protez materyallerinin stres dağılımına etkisinin değerlendirilmesi: Sonlu elemanlar analizi

    Evaluation of the effects of connector type and prosthetic material on stress distribution in tooth-implant-supported fixed prostheses: A finite element analysis study

    DİLAYCAN UĞURELİ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiBolu Abant İzzet Baysal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. KÜBRA DEĞİRMENCİ

  5. Atrofik mandibulada farklı sayılarda ve farklı materyaller ile uygulanan tam çene implant tedavilerinin sonlu eleman analizi ile karşılaştırmalı olarakdeğerlendirilmesi

    Comparative evaluation of full-arch implant treatments with different numbers and materials in atrophic mandible using finite element analysis

    ANIL KARAMAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiEge Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. TAYFUN GÜNBAY