Bireylerde kullanılan pasif kapaklı Damon Ultıma SL ve Damon Q2 SL braketlerin kapak açılma dirençlerindeki değişimlerin karşılaştırılması
A comparative evaluation of changes in slide-opening resistance of passive self-ligating Damon Ultima SL and Damon Q2 SL brackets used in individuals
- Tez No: 1008785
- Danışmanlar: PROF. DR. AHMET NEJAT ERVERDİ
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Kapaklı braket, Damon, kapak açılma kuvveti, ağız içi ortam, Self-ligating bracket, Damon, slide-opening force, intraoral environment Date: January, 2026
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Okan Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmamızın amacı, Damon Q2 ve Damon Ultima adıyla piyasaya sunulmuş olan iki farklı pasif kapaklı braket sisteminin kapak mekanizmalarının açılma dirençlerini ağız içi ortamda karşılaştırmalı olarak değerlendirmektir. Her iki braket sisteminin klinik kullanımı sırasında karşılaşılan kapak açma kuvvetleri ölçülerek, ortodontistler için klinik uygulamalarda daha güvenilir braket seçimi yapabilmesi adına bilimsel veriler sağlanması hedeflenmektedir. Çalışmamızın materyallerini kurumumuzda tedavi görmekte olan 20 hastanın tedavisinde kullanılan iki farklı pasif kapaklı üst birinci premolar braketi üzerinde yapılan ölçümler oluşturmaktadır. Damon™ Q2 SL (Ormco, Corporation, California, ABD) ve Damon™ Ultima SL (OrmcoCorporation, California, ABD) üst birinci premolar braketlerinin istatistiksel karşılaştırma için gerekli olan braket kapaklarının açılması için gereken kuvvet, kurulan deney düzeneği üzerinde dijital kuvvet ölçer kullanılarak gram cinsinden kaydedildikten sonra braketler üst premolar dişlerin palatinal yüzeylerine yapıştırılmıştır. Deney düzeneği; paralel konumlu iki siyah akrilik blok, hareketi sağlayan step motor, motor kontrol ünitesi ve dijital kuvvet ölçerden oluşmaktadır. Sabit bloğa braket kapağını açmaya yönelik mekanizma, hareketli bloğa ise kuvvet ölçer monte edilmiştir. Step motor, 5 mm/dakika sabit hızda lineer hareket üretmiştir. Kuvvet ölçer ise braket kapağının açılması için gereken kuvvetlerin hassas biçimde kaydedilmesini sağlamıştır. Braketler 3ay sonra sökülmüş ve başlangıçta yapılan ölçümler tekrarlanmıştır. Her braket için toplamda 6 ölçüm yapılmış ve gram cinsinden kaydedilmiştir. Braketlerin yapıştırma öncesi ölçümleri (T0) ve söküm sonrası ölçümleri (T1) tamamlandıktan sonra elde edilen veriler Damon Ultima braketinin T0 zamanındaki kapak açılma kuvveti ortalamasının Damon Q2 braketinden istatistiksel olarak anlamlı düzeyde yüksek olduğunu göstermiştir. Braketlerin arasında T1 zamanındaki kapak açılma kuvveti ortalamaları açısından istatistiksel olarak anlamlı bir farklılık olmamasına rağmen Damon Q2 braketinde T0 zamanına göre T1 zamanındaki kuvvet değişim miktarı, Damon Ultima braketinden istatistiksel olarak anlamlı düzeyde yüksek çıkmıştır.
Özet (Çeviri)
The aim of this study is to comparatively evaluate, under intraoral conditions, the opening resistance of the clip mechanisms of two different passive self-ligating bracket systems marketed under the names Damon Q2 and Damon Ultima. By measuring the forces required to open the clips of both bracket systems during clinical use, the study seeks to provide orthodontists with scientific data that may facilitate more reliable bracket selection in clinical practice. The materials of the study consist of measurements obtained from two different passive self-ligating maxillary first premolar brackets used in the treatment of 20 patients receiving orthodontic care at our institution. For statistical comparison, the force required to open the clips of Damon™ Q2 SL (Ormco Corporation, California, USA) and Damon™ Ultima SL (Ormco Corporation, California, USA) maxillary first premolar brackets was recorded in grams using a digital force gauge on the experimental setup, after which the brackets were bonded to the palatal surfaces of the maxillary premolar teeth. The experimental apparatus consisted of two parallel black acrylic blocks, a step motor that provided motion, a motor control unit, and a digital force gauge. A mechanism designed to open the bracket clip was mounted on the fixed block, while the force gauge was attached to the movable block. The step motor generated linear movement at a constant speed of 5 mm/min, allowing precise recording of the forces required to open the bracket clips. The brackets were debonded after three months, and the initial measurements were repeated. A total of six measurements were performed for each bracket and recorded in grams. After completing the pre-bonding (T0) and post-debonding (T1) measurements, the data demonstrated that the mean clip-opening force of the Damon Ultima bracket at T0 was statistically significantly higher than that of the Damon Q2 bracket. Although no statistically significant difference was found between the two brackets in terms of mean clip-opening forces at T1, the magnitude of force change from T0 to T1 in the Damon Q2 bracket was statistically significantly greater than that observed in the Damon Ultima bracket.
Benzer Tezler
- Farklı bireylerde kullanılan pasif kapaklı braketlerin airflow uygulaması sonrası kapak açma dirençlerindeki değişimlerin değerlendirilmesi
Evaluation of the changes in lid opening resistance of passive self-ligating brackets after airflow application in different individuals
SELİM CAN ÇAKIR
Doktora
Türkçe
2026
Diş Hekimliğiİstanbul Okan ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. AHMET NEJAT ERVERDİ
DR. ÖĞR. ÜYESİ BANU MERT
- İskeletsel sınıf 1 malokluzyona sahip hastalarda damon ve konvansiyonel braket sistemlerinin dentoalveoler yapılara olan etkilerinin incelenmesi
Evaluation of the effects of damon and conventional bracket systems on dentoalveoler structures in patients with skeletal class 1 malocclusion
MERVE KARA ÖZKAYA
Diş Hekimliği Uzmanlık
Türkçe
2018
Diş HekimliğiAkdeniz ÜniversitesiOrtodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ESRA BOLAT
- Farklı bireylerde kullanılan pasif kapaklı braketlerin kapak açılma dirençlerindeki değişimlerin in vivo değerlendirilmesi
Evaluation of changes in forces of resistance toopening slides of passive self ligated brackets
UĞUR ÖNDER
Doktora
Türkçe
2022
Diş Hekimliğiİstanbul Okan ÜniversitesiOrtodonti Ana Bilim Dalı
PROF. DR. AHMET NEJAT ERVERDİ
DOÇ. DR. YASEMİN BAHAR ACAR
- C1-C2 manipülasyonunun hamstring esnekliği üzerine etkisi
The effect of C1-C2 manipulation on hamstring flexibility
AYŞE NUR ÖZTÜRK EWAIDA
Yüksek Lisans
Türkçe
2022
Fizyoterapi ve RehabilitasyonHacettepe ÜniversitesiFizik Tedavi ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. ÖZLEM ÜLGER
- Development of e-textile based RFID enabled moisture sensor for wearable technologies
Giyilebilir teknolojiler için e-tekstil tabanlı RFID işlevli nem sensörü geliştirilmesi
MELTEM TEKÇİN
Doktora
İngilizce
2024
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiTekstil Mühendisliği Ana Bilim Dalı
DOÇ. DR. SENEM KURŞUN
PROF. DR. SELÇUK PAKER