Geri Dön

Yüksek sıcaklık uygulamalarında çarpmalı jet ve ilave kanallara sahip film soğutmanın soğutma etkinliğine etkisinin farklı parametreler altında sayısal olarak incelenmesi

Numerical investigation of the cooling effectiveness of impingement jet and film cooling with additional channels under various parameters in high-temperature applications

  1. Tez No: 1010203
  2. Yazar: FATİH ŞENYAYLA
  3. Danışmanlar: DOÇ. DR. TAMER ÇALIŞIR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Hesaplamalı akışkanlar dinamiği (HAD), Sentetik jet, Çarpan hava jetleri, Computational fluid dynamics (HAD), Synthetic jet, Impinging air jets
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Makine Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Gaz türbinlerinin ısıl verimliliğini ve itki kuvvetini artırmak için daha yüksek türbin giriş sıcaklıkları ve daha yüksek basınç oranları gerekmektedir. Ancak, türbinlerde kullanılan malzemeler bu yüksek giriş sıcaklıklarına dayanamaz. Bu nedenle, türbin giriş sıcaklığındaki artış, güvenilir işletme ve çalışma koşullarını sağlamak amacıyla çeşitli soğutma tekniklerinin geliştirilmesine yol açmıştır. Literatürde yer alan bazı deneysel çalışmalarda türbin kanadına ve yanma odasına genel soğutma etkinliğindeki (ϕ) olumlu bir etkiye sahip çarpmalı/efüzyon soğutma yönteminin uygulanmış ve çalışma sonucunda genel soğutma etkinliğindeki (ϕ) olumlu bir etkisi olduğu gözlemlenmiştir Bu çalışmada çarpmalı jet/ efüzyon soğutma uygulanmış art yakıcı ısı kalkanında bulunan film soğutma plakasına soğutma kanalları ilave edilerek oluşturulan yeni soğutucu sisteminin farklı parametreler altında soğutma etkinliği üzerindeki etkisi sayısal olarak incelenmiştir. Simülasyonlar, üfleme oranı M=0,5 – 2,0, film deliklerinin boyutsuz boyuna mesafesi sf/df=6, ilave soğutma kanallarının kütlesel debisi ṁp=0 ve 0,013 kg/s ve boyutsuz jet-film plaka mesafesi H/df= 2–18 için gerçekleştirilmiştir. Sonuçlar literatürdeki deneysel verilerle doğrulanmış ve iyi bir uyum sağlanmıştır. En dengeli ve yüksek performanslı çalışma koşullarının M = 2,0, H/df = 4-8 ve ṁp ≥ 0,0081 kg/s aralığında elde edildiği belirlenmiştir. İlave soğutma kanallarının kullanımının soğutma etkinliği üzerinde olumlu bir etkisi olduğu ve özellikle M=0,5, koşullarında ilave soğutma akışkanının kullanılmasıyla genel soğutma etkinliğinin yaklaşık %13-16 oranında artırılabileceği gözlemlenmiştir. Sonuçlar, düşük üfleme oranlarında ilave soğutma akışkanının yüksek üfleme oranlarına kıyasla daha büyük bir artış oranı sağladığını göstermektedir.

Özet (Çeviri)

Increasing the turbine inlet temperature and pressure ratio is crucial for enhancing the thermal efficiency and thrust of gas turbines. However, the materials used in turbine components are unable to withstand such high inlet temperatures, necessitating the application of advanced cooling techniques to ensure safe and reliable operation. Among these techniques, impingement/effusion cooling has been shown to provide improved overall cooling effectiveness in turbine blades and combustion chambers. In the present study, a novel cooling configuration is proposed by integrating additional cooling channels into the film cooling plate of an afterburner heat shield employing impingement jet/effusion cooling. The thermal performance of the proposed system is numerically investigated under various operating conditions. Simulations are performed for blowing ratios ranging from M= 0,5 – 2,0, a dimensionless streamwise film-hole spacing of sf/df= 6, mass flow rates of the additional cooling channels of ṁp=0 and 0,013 kg/s, and dimensionless jet-to-plate distance ratios of H/df = 2-18. The numerical results are validated by using available experimental data from the literature and a good agreement has been obtained. It was observed that the best operating conditions are identified as M = 2,0, H/df = 4-8 and ṁp≥ 0,0081 kg/s. The incorporation of additional cooling channels is found to significantly enhance the overall cooling effectiveness, particularly at low blowing ratios. At M = 0,5, the overall cooling effectiveness increases by approximately 13–16% when additional cooling flow is used. Furthermore, the results indicate that the relative enhancement provided by the additional cooling flow is more pronounced at lower blowing ratios compared to higher ones.

Benzer Tezler

  1. Uzatılmış jet çarpmalı soğutmada dalgalı hedef yüzeyin ısı geçişine etkisinin nümerik olarak incelenmesi

    Numerical investigation of the effect of wavy target surface on heat transfer in extended jet impact cooling

    KADİRCAN KASAB

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Sakarya Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Bir ilaç fabrikasında personel gereksinmesinin belirmesi seçilmesi ve elde tutulmasına yönelik bir uygulama çalışması

    Başlık çevirisi yok

    EMİNE BOZBAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Çalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı

    Yükleniyor...

  3. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  4. Halvetiyyenin Şa'baniyye kolu ve Şa'ban-ı Veli

    Başlık çevirisi yok

    L. NİHAL YAZAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...

  5. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...