Geri Dön

Genioplastide kullanılan sliding osteotomi ve box osteotomi tekniklerinin farklı plak tasarımları ile kombinasyonunun sonlu elemanlar analizi ile incelenmesi

A finite element analysis of sliding and box osteotomy techniques combined with di̇fferent plate designs in genioplasty

  1. Tez No: 1023685
  2. Yazar: SERKAN SERT
  3. Danışmanlar: PROF. DR. EMEL BULUT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı, genioplastide kullanılan Sliding osteotomi ve Box osteotomi tekniklerinin farklı plak tasarımları ile kombinasyonlarının biyomekanik davranışlarını sonlu elemanlar analizi yöntemiyle değerlendirmek ve osteotomi tipi, fiksasyon sistemi, hareket miktarı ve hareket yönünün kemik, plak ve vida sistemleri üzerindeki etkilerini karşılaştırmaktır. Materyal ve Metot: Çalışmada insan mandibulasına ait üç boyutlu bir model kullanılarak Sliding osteotomi ve Box osteotomi teknikleri modellenmiştir. Her osteotomi modeli çift düz plak ve Y plak fiksasyon sistemleri ile kombine edilmiş; 4 mm ve 8 mm ileri ile geri hareket senaryoları uygulanmıştır. Toplam 16 farklı model üzerinde suprahyoid kas çekişleri taklit edilerek ortaya çıkan deplasman ve stres değerleri sonlu elemanlar analizi ile değerlendirilmiştir. Bulgular: Hareket miktarının artması incelenen tüm modellerde stres ve deplasman değerlerinde artışa neden olmuştur. Kortikal ve trabeküler kemikte gözlenen stres dağılımları osteotomi tipi ve fiksasyon sistemine bağlı olarak değişkenlik göstermiştir. Y plak kullanılan modellerde plak ve vida sistemlerinde daha yüksek stres konsantrasyonları izlenirken, çift düz plak kullanılan modellerde streslerin daha dengeli dağıldığı görülmüştür. Deplasman değerleri incelendiğinde, çift düz plak konfigürasyonlarının genel olarak daha yüksek stabilite sağladığı belirlenmiştir. Hareket yönünün biyomekanik parametreler üzerinde etkili olduğu gözlenmekle birlikte, hareket miktarının etkisinin daha belirgin olduğu saptanmıştır. Sonuç: Genioplasti cerrahisinde osteotomi tipi, fiksasyon sistemi ve hareket miktarı biyomekanik davranışı etkileyen temel faktörlerdir. Çift düz plak konfigürasyonu, stres dağılımı ve stabilite açısından daha avantajlı sonuçlar göstermiştir. Box osteotomi tekniği ise biyomekanik açıdan Sliding osteotomiye alternatif oluşturabilecek özellikler sergilemiştir. Sonlu elemanlar analizi ile elde edilen bulguların, genioplasti cerrahisinde osteotomi ve fiksasyon tercihlerine yönelik klinik karar süreçlerine katkı sağlayacağı düşünülmektedir.

Özet (Çeviri)

Objective: The aim of this study was to evaluate the biomechanical behavior of combinations of Sliding Osteotomy and Box Osteotomy techniques used in genioplasty with different plate designs using finite element analysis, and to compare the effects of osteotomy type, fixation system, amount of movement, and direction of movement on bone, plate, and screw systems. Materials and Methods: In this study, three-dimensional models of the human mandible were used to simulate Sliding Osteotomy and Box Osteotomy techniques. Each osteotomy model was combined with either a double straight plate or a Y-shaped plate fixation system, and subjected to 4 mm and 8 mm advancement and setback movement scenarios. A total of 16 different models were analyzed by simulating suprahyoid muscle forces, and the resulting displacement and stress values were evaluated using finite element analysis. Results: An increase in the amount of movement resulted in higher stress and displacement values in all models. Stress distributions observed in cortical and trabecular bone varied depending on the osteotomy type and fixation system. Higher stress concentrations were observed in the plate and screw systems of the Y-shaped plate models, whereas stress was distributed more evenly in the double straight plate models. Evaluation of displacement values demonstrated that double straight plate configurations generally provided greater stability. Although the direction of movement influenced biomechanical parameters, the effect of movement magnitude was found to be more pronounced. Conclusion: Osteotomy type, fixation system, and movement magnitude are major factors influencing biomechanical behavior in genioplasty surgery. The double straight plate configuration demonstrated more favorable outcomes in terms of stress distribution and stability. The Box Osteotomy technique exhibited biomechanical characteristics that may represent a viable alternative to the Sliding Osteotomy technique. The findings obtained through finite element analysis may contribute to clinical decision-making regarding osteotomy and fixation preferences in genioplasty surgery.

Benzer Tezler

  1. Genioplastide kullanılan iki farklı plak tasarımının farklı açılarda uygulanmasının stabiliteye etkisinin biyomekanik olarak karşılaştırılması

    Biomechanical comparison of the effects of application of two different plate design used in genioplasty in different angles on stability

    MUSTAFA AY

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiOrdu Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BURAK CEZAİRLİ

  2. Genioplastide kullanılan titanyum plaklar ve rezorbe olabilen plakların stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesi

    Evaluation of stability and stress distributions of titanium and resorbable plates used in genioplasty by finite element analysis

    BERİVAN KOZAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş Hekimliğiİnönü Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. BAHADIR SANCAR

  3. Alt çene ucu ilerletmesinde kullanılan farklı vida sistemlerinin stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesi

    Evaluation of stability and stress distributions of different screw fixation systems used in advancement genioplasty by using the finite element analysis

    HALE YURTYAPAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2018

    Diş HekimliğiOrdu Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FERHAT AYRANCI

  4. İlerletme genioplastisinde fiksasyon amaçlı kullanılan farklı plak ve vida sistemlerinin stabilite ve stres dağılımlarının sonlu elemanlar analizi ile değerlendirilmesi

    Evaluation of stability and stress distributions of different plate and screw systems used for fixation purposes in advancement genioplasty with finite element analysis

    AHMET AKTI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiSelçuk Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. ABDULLAH KALAYCI

  5. Alt çene ucu plastisinin (genioplasti) farklı cerrahi teknikler uygulanarak dil ve hyoid kemik pozisyonlarında meydana gelen değişikliklerin sonlu elemanlar analizi ile incelenmesi

    Investigation of mandibular chin plasty (genioplasty) with finite element analysis of changes in tongue and hyoid bone positions by applying different surgical techniques

    İREM GÜLLERCİ

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. MEHMET EMRE YURTTUTAN