CAD/CAM restoratif materyallerde farklı polisaj sistemlerinin kullanımının yüzey özellikleri üzerindeki etkilerinin incelenmesi
Evaluation of the effects of using different polishing systems on surface properties on CAD/CAM restorative materials
- Tez No: 1024315
- Danışmanlar: DOÇ. DR. TUĞBA SERİN KALAY
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Karadeniz Teknik Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Restoratif Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Restoratif Diş Tedavisi Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu in vitro tez çalışmasının amacı, farklı kimyasal yapıya sahip üç güncel estetik CAD/CAM materyalinde uygulanan farklı polisaj protokollerinin yüzey pürüzlülüğü, aşınma davranışı ve antagonist üzerindeki etkilerini karşılaştırmalı olarak değerlendirmektir. Çalışmada rezin nanoseramik Lava Ultimate, hibrit seramik Vita Enamic ve zirkonya ile güçlendirilmiş lityum silikat cam seramik Vita Suprinity kullanılmıştır. Her materyalden hazırlanan standart örnekler; kontrol, frez, üretici önerisi, EVE Diapol Twist RA306 ve EVE Universal RA101 olmak üzere beş alt gruba ayrılmıştır. Klinik oklüzal uyumlama elmas frez ile simüle edilmiş, polisaj işlemleri üretici önerilerine uygun şekilde uygulanmıştır. Yüzey pürüzlülüğü profilometre, yüzey morfolojisi taramalı elektron mikroskobu (SEM) ile değerlendirilmiştir. Aşınma testi sırasında sürtünme katsayısı kaydedilmiş; aşınma öncesi ve sonrası elde edilen üç boyutlu taramalar karşılaştırılarak maksimum aşınma derinliği, ortalama maksimum aşınma derinliği ve hacim kaybı hesaplanmıştır. İstatistiksel analizlerde tek yönlü ve iki yönlü varyans analizleri ile Tukey HSD post hoc testi kullanılmış, anlamlılık düzeyi p<0,05 olarak kabul edilmiştir. Sertlik bakımından materyaller arasında anlamlı fark bulunmuş (p<0,001); en yüksek sertlik Vita Suprinity, en düşük sertlik ise Lava Ultimate'da belirlenmiştir. Tüm materyallerde yüzey işlemleri yüzey pürüzlülüğünü anlamlı düzeyde etkilemiş (p<0,001); en düşük pürüzlülük kontrol, en yüksek pürüzlülük frez gruplarında gözlenmiştir. Polisaj uygulamaları frez sonrası oluşan pürüzlülüğü anlamlı düzeyde azaltmıştır. Sürtünme katsayısı Vita Enamic ve Vita Suprinity'de yüzey işlemlerinden etkilenirken (p<0,05), Lava Ultimate'da anlamlı farklılık saptanmamıştır (p>0,05). Maksimum aşınma derinliği, ortalama maksimum aşınma derinliği ve hacim kaybı bakımından yüzey işlemleri arasında anlamlı fark bulunmuş (p<0,05); en yüksek aşınma frez gruplarında, daha düşük değerler ise polisaj gruplarında elde edilmiştir. İki yönlü varyans analizinde materyal ve yüzey işlemi ana etkileri tüm değişkenlerde anlamlı bulunurken, hacim kaybı dışında materyal × yüzey işlemi etkileşimi de anlamlı bulunmuştur (p<0,001). Polisaj sistemlerinin etkinliği CAD/CAM materyallerinin kimyasal ve mikroyapısal özelliklerine bağlı olarak değişmektedir. Materyale uygun polisaj sisteminin seçimi, yüzey özelliklerinin iyileştirilmesi, aşınmanın azaltılması ve restorasyonların uzun dönem başarısının desteklenmesi açısından önem taşımaktadır.
Özet (Çeviri)
The aim of this in vitro thesis study was to comparatively evaluate the effects of different polishing protocols on surface roughness, wear behavior, and antagonist wear of three contemporary esthetic CAD/CAM materials with different chemical compositions. Resin nanoceramic Lava Ultimate, hybrid ceramic Vita Enamic, and zirconia-reinforced lithium silicate glass-ceramic Vita Suprinity were evaluated. Standardized specimens were prepared from each material and divided into five subgroups: control, bur-treated, manufacturer-recommended polishing, EVE Diapol Twist RA306, and EVE Universal RA101. Clinical occlusal adjustment was simulated using a diamond bur, and polishing procedures were performed according to the manufacturers' instructions. Surface roughness was measured using a profilometer, while surface morphology was evaluated by scanning electron microscopy (SEM). During the wear test, the coefficient of friction was recorded. Three-dimensional scans obtained before and after wear were superimposed to calculate maximum wear depth, mean maximum wear depth, and volumetric wear loss. Statistical analyses were performed using one-way and two-way analysis of variance (ANOVA) and Tukey's HSD post hoc test, with the level of significance set at p<0.05. A significant difference in hardness was observed among the materials (p<0.001), with Vita Suprinity exhibiting the highest hardness and Lava Ultimate the lowest. Surface treatments significantly affected surface roughness in all materials (p<0.001); the lowest roughness values were observed in the control groups, whereas the highest values were recorded in the bur-treated groups. Polishing procedures significantly reduced the surface roughness produced by bur treatment. The coefficient of friction was significantly influenced by surface treatment in Vita Enamic and Vita Suprinity (p<0.05), whereas no significant difference was observed in Lava Ultimate (p>0.05). Significant differences among surface treatment groups were also found for maximum wear depth, mean maximum wear depth, and volumetric wear loss (p<0.05). The highest wear values were observed in the bur-treated groups, while lower wear values were obtained after polishing. Two-way ANOVA demonstrated significant main effects of material and surface treatment for all variables. In addition, a significant material × surface treatment interaction was observed for all variables except volumetric wear loss (p<0.001). The effectiveness of polishing systems depends on the chemical composition and microstructural characteristics of CAD/CAM materials. Therefore, selecting a polishing system appropriate for the restorative material is essential for improving surface properties, minimizing wear, and supporting the long-term clinical performance of restorations.
Benzer Tezler
- 1985-1986 yıllarında Polatlı Devlet Hastanesine kaza nedeniyle başvuranların incelenmesi
Başlık çevirisi yok
FERHAN ŞENOL
Yüksek Lisans
Türkçe
1986
Gazi ÜniversitesiKazaların Çevresel ve Teknik Araştırması Ana Bilim Dalı (disiplinlerarası)
Yükleniyor...
- Soyanın çeşitli gelişme dönemlerinde topraktan kaldırdığı besin maddeleri ve büyümesi ile verim arasındaki ilişkiler
Başlık çevirisi yok
MERAL GİRGİN
- Yahya Kemal'de bedii tefekkür unsurları: 1 Kendi Gök Kubbemiz'de duygu
Başlık çevirisi yok
MUSTAFA ÖZBALCI
- Mevcut kaplıca yerleşmelerinin iyileştirilmesini etkileyen faktörler ve Yeni Kaplıca örneği
Adjustment principles of spas in Turkey, Yeni Kaplıca being the sample
DOĞAN ÜMİT YÜCEL