Klinik koşullarda anterior ve posterior dişlerde renk belirlemede kullanılan farklı ölçüm yöntemlerinin doğruluk ve tekrarlanabilirliklerinin CIELAB sistemine göre karşılaştırılması
Comparison of the accuracy and repeatability of different methods used for shade determination in anterior and posterior teeth under clinical conditions according to the CIELAB system
- Tez No: 1025818
- Danışmanlar: PROF. DR. SİMEL AYYILDIZ
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Sağlık Bilimleri Üniversitesi
- Enstitü: Gülhane Diş Hekimliği Fakültesi (ankara)
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, klinik koşullarda farklı yöntemlerle elde edilen diş rengi ölçümlerini karşılaştırarak, bu yöntemlerin spektrofotometrik referans yönteme göre doğruluk ve tekrarlanabilirliklerini değerlendirmek ve klinik kullanım açısından güvenilirliklerini ortaya koymaktır. Gereç ve Yöntem: Bu klinik çalışmada, 50 bireyin maksiller anterior (11, 13) ve posterior (16) dişlerinden elde edilen renk ölçümleri değerlendirilmiştir. Renk belirleme işlemleri görsel yöntem, ağız içi tarayıcı ve mobil uygulama kullanılarak gerçekleştirilmiş; spektrofotometrik ölçümler referans yöntem olarak kabul edilmiştir. Ölçümler standardize aydınlatma koşullarında ve dişlerin orta üçlü bölgeleri referans alınarak yapılmıştır. Elde edilen veriler CIELAB renk sistemine göre analiz edilmiş; L*, a* ve b* parametreleri ile renk farkı (ΔE) değerleri hesaplanmıştır. Ölçüm yöntemleri arasındaki farkların değerlendirilmesinin yanı sıra, anterior ve posterior bölgeler arasında karşılaştırmalar yapılmıştır. Verilerin normal dağılıma uygunluğu Shapiro–Wilk testi ile değerlendirilmiş, parametrik olmayan analizler tercih edilmiştir. Üç bağımlı grubun karşılaştırılmasında Friedman testi, ikili karşılaştırmalarda Wilcoxon işaretli sıralar testi kullanılmış ve Bonferroni düzeltmesi uygulanmıştır (p<0.05). Her ölçüm yöntemine ait CIELAB parametrelerinin tekrarlanabilirliği grupiçi korelasyon katsayısı (ICC) ile değerlendirilmiştir. Bulgular: Tüm diş gruplarında ölçüm yöntemleri arasında ΔE değerleri açısından istatistiksel olarak anlamlı fark bulunmuştur (p<0.001). En düşük ΔE değerleri görsel yöntemde, en yüksek değerler ise mobil uygulamada elde edilmiştir. Ağız içi tarayıcı ile görsel yöntem arasında genel olarak anlamlı fark saptanmazken, mobil uygulama diğer yöntemlere kıyasla daha yüksek ΔE değerleri göstermiştir. Posterior bölgede tüm yöntemlerde ΔE değerlerinin arttığı, bu artışın mobil uygulamada daha belirgin olduğu gözlemlenmiştir. Tüm yöntemlerde yüksek tekrarlanabilirlik elde edilmiş, yöntemler arasında tekrarlanabilirlik açısından anlamlı fark bulunmamıştır. Sonuç: Bu çalışmanın bulgularına göre, incelenen yöntemler arasında spektrofotometrik referansa göre en düşük renk farkı görsel yöntemle elde edilmiştir. Ağız içi tarayıcı, anterior ve posterior bölgeler arasında istatistiksel olarak anlamlı bir fark göstermeyerek tutarlı bir performans sergilemiştir. Mobil uygulama ise özellikle posterior bölgede daha yüksek hata payı ve düşük parlaklık değerleri ile klinik kullanım açısından sınırlılıklar göstermiştir. Tekrarlanabilirlik analizi, tüm yöntemlerin kendi içinde yüksek tutarlılık sergilediğini ancak mobil uygulamanın doğruluk açısından klinik beklentilerin gerisinde kaldığını ortaya koymuştur.
Özet (Çeviri)
Objective: The aim of this clinical study was to compare tooth color measurements obtained using different shade determination methods under clinical conditions and to evaluate their accuracy and repeatability relative to a spectrophotometric reference method, as well as their reliability for clinical application. Materials and Methods: In this clinical study, color measurements obtained from the maxillary anterior (11, 13) and posterior (16) teeth of 50 participants were evaluated. Shade determination procedures were performed using a visual method, an intraoral scanner, and a mobile application, while spectrophotometric measurements were accepted as the reference method. All measurements were conducted under standardized lighting conditions using the middle third of the teeth as the reference area. The obtained data were analyzed according to the CIELAB color system, and L*, a*, b* parameters together with color difference (ΔE) values were calculated. In addition to evaluating differences among measurement methods, comparisons were also made between anterior and posterior regions. The normality of the data distribution was assessed using the Shapiro–Wilk test, and non-parametric analyses were preferred. The Friedman test was used for comparisons among three dependent groups, while pairwise comparisons were performed using the Wilcoxon signed-rank test with Bonferroni correction applied (p<0.05). The repeatability of the CIELAB parameters for each measurement method was evaluated using the intraclass correlation coefficient (ICC). Results: Statistically significant differences in ΔE values were found among the measurement methods in all tooth groups (p<0.001). The lowest ΔE values were obtained with the visual method, whereas the highest values were observed with the mobile application. No significant differences were generally detected between the intraoral scanner and the visual method; however, the mobile application demonstrated higher ΔE values compared with the other methods. ΔE values increased in the posterior region for all methods, and this increase was more pronounced in the mobile application measurements. High repeatability was observed for all methods, and no significant differences in repeatability were detected among the measurement methods. Conclusion: According to the findings of this study, the visual method demonstrated the lowest color difference relative to the spectrophotometric reference among the evaluated methods. The intraoral scanner exhibited consistent performance without showing statistically significant differences between anterior and posterior regions. In contrast, the mobile application demonstrated limitations for clinical use, particularly in posterior regions, due to higher error rates and lower lightness values. Repeatability analysis revealed that all methods showed high internal consistency; however, the mobile application showed limited clinical applicibilaty in terms of accuracy.
Benzer Tezler
- Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi
Başlık çevirisi yok
NECDET ŞÜKRÜ ALTUN
- Türkiye'de serebral hareket bozukluklarının etiyolojisi epidemiyolojisi ve bazı klinik özellikleri
Başlık çevirisi yok
AŞER BENSUSAN
Tıpta Uzmanlık
Türkçe
1986
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
Yükleniyor...
- Pre-eklampsi ve eklampsi vakalarında immünoglobülin düzeylerinin değerlendirilmesi (Klinik ve immünobiolojik araştırma)
Examination des valeurs d'immunoglobulines en cas de la toxemie gravidique
M. MURAT SEMİZ
- Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi
Başlık çevirisi yok
AYGÜN DİNDAR
Tıpta Uzmanlık
Türkçe
1987
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı
Yükleniyor...