T.O.HO. skorunun ekstrakorporeal şok dalga litotripsisi başarısını öngörmedeki değeri
The value of the T.O.HO. score in predicting the success of extracorporeal shock wave lithotripsy
- Tez No: 1025959
- Danışmanlar: PROF. DR. FARUK ÖZGÖR
- Tez Türü: Tıpta Uzmanlık
- Konular: Üroloji, Urology
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Sağlık Bilimleri Üniversitesi
- Enstitü: İstanbul Haseki Eğitim ve Araştırma Hastanesi
- Ana Bilim Dalı: Üroloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmada, fleksibl üreterorenoskopi (f-URS) için geliştirilen T.O.HO. skorunun, ekstrakorporeal şok dalga litotripsisi (ESWL) uygulanan böbrek ve proksimal üreter taşı hastalarında tedavi başarısını öngörmedeki değeri araştırıldı; Triple-D, Quadruple-D ve S3HoCKwave skorlarıyla karşılaştırıldı ve cilt-taş mesafesinin modele katkısı değerlendirildi. Gereç ve Yöntemler: Tek merkezli retrospektif bu çalışmada, 01 Aralık 2021–01 Aralık 2025 tarihleri arasında ESWL uygulanan 447 erişkin hasta değerlendirildi. Tedavi başarısı, ESWL sonrası 4–6. haftada direkt üriner sistem grafisi (DÜSG) + üriner sistem ultrasonografisi (US) veya kontrastsız bilgisayarlı tomografide (BT) hedef taşa ait rezidü taş izlenmemesi olarak tanımlandı. Her hasta için T.O.HO., Triple-D, Quadruple-D ve S3HoCKwave skorları hesaplandı. Modellerin performansı ROC-AUC analiziyle değerlendirildi ve DeLong testiyle karşılaştırıldı. Bulgular: Hastaların 293'ünde (%65,5) tedavi başarısı sağlandı. Başarısız grupta vücut kitle indeksi (VKİ), taş boyutu, taş volümü, cilt-taş mesafesi, Hounsfield ünitesi (HU) değeri ve alt kaliks taş oranı daha yüksekti. Çok değişkenli analizde taş volümü, alt kaliks dışı lokalizasyon, cilt-taş mesafesi ve HU değeri ESWL başarısıyla bağımsız ilişkili bulundu. ROC analizinde T.O.HO., Triple-D, Quadruple-D, S3HoCKwave ve T.O.HO. + cilt-taş mesafesi modellerinin AUC değerleri sırasıyla 0,681, 0,776, 0,793, 0,765 ve 0,773 idi. T.O.HO. + cilt-taş mesafesi modeli, T.O.HO. skoruna göre anlamlı üstünlük gösterdi ve Quadruple-D ile benzer performans sergiledi. Sonuç: T.O.HO. skoru ESWL başarısını tek başına orta düzeyde öngörmektedir. Cilt-taş mesafesinin eklenmesi prediktif performansı belirgin şekilde artırmakta ve modeli mevcut güçlü ESWL skorlama sistemleriyle karşılaştırılabilir düzeye getirmektedir.
Özet (Çeviri)
Aim: This study investigated the predictive value of the T.O.HO. score, originally developed for flexible ureterorenoscopy (f-URS), in patients undergoing extracorporeal shock wave lithotripsy (ESWL) for renal and proximal ureteral stones. It was also compared with the Triple-D, Quadruple-D, and S3HoCKwave scores, and the contribution of skin-to-stone distance to the model was evaluated. Materials and Methods: In this single-center retrospective study, 447 adult patients who underwent ESWL between December 1, 2021, and December 1, 2025, were evaluated. Treatment success was defined as the absence of residual fragments related to the target stone on kidney-ureter-bladder radiography (KUB) + urinary system ultrasonography (US) or non-contrast computed tomography (CT) performed 4–6 weeks after ESWL. T.O.HO., Triple-D, Quadruple-D, and S3HoCKwave scores were calculated for each patient. Model performance was assessed using ROC-AUC analysis and compared with the DeLong test. Results: Treatment success was achieved in 293 patients (65.5%). Body mass index (BMI), stone size, stone volume, skin-to-stone distance, Hounsfield unit (HU) value, and the proportion of lower calyceal stones were higher in the unsuccessful group. In multivariate analysis, stone volume, non-lower calyceal localization, skin-to-stone distance, and HU value were independently associated with ESWL success. In ROC analysis, the AUC values of the T.O.HO., Triple-D, Quadruple-D, S3HoCKwave, and T.O.HO. + skin-to-stone distance models were 0.681, 0.776, 0.793, 0.765, and 0.773, respectively. The T.O.HO. + skin-to-stone distance model showed significantly better performance than the T.O.HO. score alone and demonstrated comparable performance to the Quadruple-D score. Conclusion: The T.O.HO. score alone predicts ESWL success with moderate accuracy. Adding skin-to-stone distance markedly improves its predictive performance and brings the model to a level comparable with established ESWL scoring systems.
Benzer Tezler
- Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi
Başlık çevirisi yok
MERİH BAYRAM
- Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi
Kinetic study and detesmination of thermodnamic parameters of some esters
İBRAHİM TAŞ
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Atherosklerotik kalp hastalıklarında risk faktörleri
Risk factors in the coronary artery disease
MURAT SUHER