Geri Dön

Farklı fotogrametri yöntemleri ile alınan tam ark implant üstü ölçülerin doğruluk ve hassasiyetinin değerlendirilmesi

Assessment of the accuracy and precision of full-arch implant-supported impressions obtained with different photogrammetry methods

  1. Tez No: 1027698
  2. Yazar: MEHMET NECİP SELVİ
  3. Danışmanlar: DOÇ. DR. MÜNİR DEMİREL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Stereofotogrametri, Stereophotogrammetry
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Biruni Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu in vitro çalışmanın amacı, mandibular tam ark dişsiz bir modelde ağız içi fotogrametri, ağız dışı fotogrametri ve konvansiyonel açık kaşık ölçü yöntemlerinin yüzey ve çizgisel doğruluk ile hassasiyetini karşılaştırmaktır. Çalışmada 6 multi-unit dayanak analoğu içeren standardize edilmiş alçı ana model kullanılmıştır. Referans veri yüksek çözünürlüklü endüstriyel bir tarayıcı ile elde edilmiştir. Test verileri Aoralscan Elite (Elite), Icam4D (I4D), OxoFit (OXO) ve konvansiyonel açık kaşık ölçü (KNV) gruplarında, her grup için 20 ölçü alınarak oluşturulmuştur. Toplam 80 test STL dosyası, referans STL dosyasıyla karşılaştırılmıştır. Yüzey sapması“RMS”, çizgisel sapma ise multi-unit dayanak merkezleri arasındaki mesafe farklarıyla değerlendirilmiştir. Hassasiyet değerlendirmesinde“RMS_SD”ve“Mesafe_SD”değerleri kullanılmıştır. Tüm parametrelerde gruplar arasında anlamlı farklar bulunmuştur (p<.001). Yüzey doğruluğunda OXO grubu en yüksek“RMS”değerini göstermiş, Elite, I4D ve KNV grupları arasında anlamlı fark saptanmamıştır. Yüzey ve çizgisel hassasiyette I4D grubu en düşük“RMS_SD”ve“Mesafe_SD”değerlerini göstermiştir. Çizgisel mesafe doğruluğunda ise KNV grubu en düşük Mesafe değerini göstermiştir. Bu çalışmanın sınırları içinde, test edilen kayıt yöntemlerinin doğruluk ve hassasiyet profillerinin kullanılan yönteme ve değerlendirme parametresine göre değiştiği görülmüştür. Fotogrametri sistemleri konvansiyonel ölçüye alternatif dijital kayıt yöntemleri olarak değerlendirilebilir; ancak klinik uyuma ilişkin sonuçlar ek klinik çalışmalarla desteklenmelidir.

Özet (Çeviri)

The aim of this in vitro study was to compare the surface and linear accuracy and precision of intraoral photogrammetry, extraoral photogrammetry, and conventional open-tray impression methods in a mandibular full-arch edentulous model. A standardized gypsum master model containing 6 multi-unit abutment analogs was used. The reference data were obtained with a high-resolution industrial scanner. Test data were obtained from the Aoralscan Elite (Elite), Icam4D (I4D), OxoFit (OXO), and conventional open-tray impression (KNV) groups, with 20 impressions obtained for each group. A total of 80 test STL files were compared with the reference STL file. Surface deviation was evaluated using“RMS”values, while linear deviation was assessed based on the distance differences between the centers of the multi-unit abutments.“RMS_SD”and“Mesafe_SD”values were used for precision assessment. Significant differences were found among the groups for all parameters (p<.001). In surface accuracy, the OXO group showed the highest“RMS”value, while no significant difference was found among the Elite, I4D, and KNV groups. In surface and linear precision, the I4D group showed the lowest“RMS_SD”and“Mesafe_SD”values. In linear distance accuracy, the KNV group showed the lowest“Mesafe”value. Within the limitations of this study, the accuracy and precision profiles of the tested recording methods varied according to the method used and the evaluation parameter. Photogrammetry systems may be considered digital impression methods alternative to conventional impressions; however, results related to clinical fit should be supported by further clinical studies.

Benzer Tezler

  1. Dijital ve yarı-dijital iş akışlarının tam ark implant üstü ölçüleri üzerindeki doğruluk ve hassasiyetinin karşılaştırılması

    Comparison of trueness and precision of digital and semi-digital workflows on complete-arch implant impressions

    MÜNİR DEMİREL

    Doktora

    Türkçe

    Türkçe

    2022

    Biruni Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  3. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  4. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  5. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...