Üç boyutlu yazıcı ile üretilen oklüzal splint materyallerine nanopartikül ilavesinin fiziksel ve mekanik özellikleri üzerine etkilerinin değerlendirilmesi
Evaluation of the effect on physical and mechanical properties of nanoparticle-enhanced occlusal splint materials manufactured by three dimensional printer
- Tez No: 1028010
- Danışmanlar: DR. ÖĞR. ÜYESİ DALNDUSHE ABDULAI
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Üç boyutlu yazıcı, Three dimensional printer
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Biruni Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tez çalışmasının amacı, üç boyutlu yazıcı ile üretilen oklüzal splint rezinine farklı oranlarda titanyum dioksit (TiO₂) ve zirkonyum oksit (ZrO₂) nanopartikülleri ilavesinin termal siklus öncesi ve sonrası materyalin renk değişimi, yüzey pürüzlülüğü ve Vickers mikrosertlik özellikleri üzerindeki etkilerinin değerlendirilmesidir. Çalışmada, üç boyutlu yazıcı ile üretilen oklüzal splint rezinine farklı oranlarda titanyum dioksit (TiO₂) ve zirkonyum oksit (ZrO₂) nanopartikülleri ilave edilerek numuneler hazırlanmıştır. Nanopartikül içermeyen grup kontrol grubu olarak belirlenmiş; %1, %2 ve %3 oranlarında ZrO₂ içeren gruplar ile %1, %2 ve %3 oranlarında TiO₂ içeren gruplar oluşturulmuştur. Maskeli Stereolitografi (mSLA) üretim teknolojisine sahip üç boyutlu yazıcı kullanılarak toplam 217 numune üretilmiş ve numuneler yedi gruba ayrılmıştır. Numunelerin renk ölçümleri spektrofotometre ile, yüzey pürüzlülüğü ölçümleri profilometre ile ve Vickers mikrosertlik ölçümleri mikrosertlik cihazı ile gerçekleştirilmiştir. Tüm numuneler termal siklus işlemine tabi tutulmuş ve ölçümler tekrarlanmıştır. Ayrıca yüzey morfolojileri alan emisyonlu taramalı elektron mikroskobu (FE-SEM), elementel bileşimleri ise enerji dağılımlı X-ışını spektroskopisi (EDS) ile değerlendirilmiştir. TiO₂ ve ZrO₂ nanopartikül ilavesi, oklüzal splint materyallerinin renk değişimi (p<0,001), yüzey pürüzlülüğü(p=0,001) ve Vickers mikrosertlik (p=0,001) değerlerini etkilemiştir. Nanopartikül konsantrasyonundaki artışla birlikte renk değişimi ve yüzey pürüzlülüğünde artış eğilimi gözlenmiştir. Mikrosertlik değerleri ise özellikle yüksek konsantrasyonlu TiO₂ ve ZrO₂ gruplarında artış göstermiştir. TiO₂ ve ZrO₂ nanopartikülleri ilave edilen üç boyutlu oklüzal splint materyallerinin fiziksel ve mekanik özelliklerinin geliştirilebileceği, ancak nanopartikül tipi ve konsantrasyonunun materyal performansı üzerinde belirleyici olduğu sonucuna varılmıştır.
Özet (Çeviri)
The aim of this thesis was to evaluate the effects of incorporating different concentrations of titanium dioxide (TiO₂) and zirconium dioxide (ZrO₂) nanoparticles into three-dimensionally printed occlusal splint resin on color change, surface roughness, and Vickers microhardness properties before and after thermocycling. In this study, specimens were prepared by adding different concentrations of TiO₂ and ZrO₂ nanoparticles to a three-dimensionally printed occlusal splint resin. A nanoparticle-free group served as the control group, while experimental groups containing 1%, 2%, 3% ZrO₂ and TiO₂ nanoparticles were established. A total of 217 specimens were fabricated using a masked stereolithography (mSLA) three-dimensional printer and divided into seven groups. Color measurements were performed using a spectrophotometer, surface roughness was assessed with a profilometer, and Vickers microhardness was determined using a microhardness tester. All specimens were subjected to thermocycling and the measurements were repeated. Surface morphology was evaluated using field emission scanning electron microscopy (FE-SEM), while elemental composition was analyzed by energy-dispersive X-ray spectroscopy (EDS). The incorporation of TiO₂ and ZrO₂ nanoparticles affected the color change, surface roughness, and Vickers microhardness of the occlusal splint materials. An increasing trend in color change and surface roughness values was observed with increasing nanoparticle concentration. Microhardness values increased particularly in the groups containing higher concentrations of TiO₂ and ZrO₂ nanoparticles. It can be concluded that the physical and mechanical properties of three-dimensionally printed occlusal splint materials may be improved by the incorporation of TiO₂ and ZrO₂ nanoparticles. However, nanoparticle type and concentration were found to be critical factors influencing the overall material performance.
Benzer Tezler
- Üç boyutlu yazıcılarda farklı açı ve katman kalınlığında üretilen splint reçinelerinin fiziksel ve mekanik özelliklerinin karşılaştırılması
A comparison of the physical and mechanical properties of splint resins produced at different angles and layer thickness in 3D printers
BEYZA TANDOĞAN
- Üç boyutlu yazıcı ile direkt üretilen şeffaf plakların okluzal kuvvetler altındaki boyutsal değişimlerinin sonlu eleman analizi ile incelenmesi
Investigation of dimensional changes under occlusal forces of direct 3D printed clear aligners with finite element analysis
SİMGE AYAZOĞLU
- Üç boyutlu yazıcı ile üretilen geçici kuron-köprü materyallerinin fiziksel özelliklerinin ve bükülme mukavemetinin değerlendirilmesi
Evaluation of physical properties and flexural strength of temporary crown-bridge materials produced with three-dimensional printer
KÜBRA AYCAN TAVUZ
- Üç boyutlu yazıcı ile üretilen ortodontik braketlerin mekanik özelliklerinin sonlu elemanlar analizi ile incelenmesi
Investigation of the mechanical properties of orthodontic brackets produced with three-dimensional printer by finite element analysis
SENANUR İSKURT MISIROĞLU
- Üç boyutlu yazıcı ile farklı rezinlerden üretilen dental restorasyonların mekanik özelliklerinin incelenmesi
Mechanical analysis of 3D printed dental restorations produced from different resins
BUSE ÇEBİ GÜL