ÇİFT LÜMENLİ TÜP VE TEK LÜMENLİ TÜP ENTÜBASYONUNUN HEMODİNAMİK YANIT ÜZERİNE OLAN ETKİLERİNİN KARŞILAŞTIRILMASI
ÇİFT LÜMENLİ TÜP VE TEK LÜMENLİ TÜP ENTÜBASYONUNUN HEMODİNAMİK YANIT ÜZERİNE OLAN ETKİLERİNİN KARŞILAŞTIRILMASI
- Tez No: 1029168
- Danışmanlar: UZMAN POLAT PEHLİVANOĞLU
- Tez Türü: Tıpta Uzmanlık
- Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
- Anahtar Kelimeler: Çift lümenli endobronşiyal tüp, tek lümenli tüp, hemodinamik yanıt, Double-lumen endobronchial tube, single-lumen tube, hemodynamic response
- Yıl: 2014
- Dil: Türkçe
- Üniversite: Sağlık Bakanlığı
- Enstitü: Ankara Atatürk Göğüs Hastalıkları ve Göğüs Cerrahisi Eğitim ve Araştırma Hastanesi
- Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Biz bu çalışmamızda bispektral indeks (BİS) kullanılarak yeterli anestezi derinliği sağlanan hastalarda tek lümenli endotrakeal ve çift lümenli endobronşiyal entübasyon sırasında laringoskopi ve entübasyona alınan hemodinamik yanıtların karşılaştırılmasını amaçladık. Yöntem: Hastalar prospektif olarak iki gruba randomize edildi. Her gruba 41'er hasta alındı. Grup 1 çift lümenli endobronşiyal tüple entübe edilirken; Grup 2, tek lümenli tüple entübe edildi. Her iki grupta sistolik arteryal basınç (SAB), diyastolik arteryal basınç (DAB), ortalama arteryal basınç (OAB), kalp atım hızı (KAH), periferal oksijen saturasyonu (SpO2) ve Bispektral indeks (BİS) monitorizasyonu değerlerine bakılarak hastaların hemodinamik yanıtları değerlendirildi. Tüm bu değerler premedikasyondan önce (T1), indüksiyondan önce (T2), indüksiyondan sonra entübasyondan önce (T3), entübasyondan sonra 1. dk (T4), 3. dk (T5), 5. dk (T6), 7,5. dk (T7), 10. dk (T8), 12,5. dk (T9), 15. dk T(10), ve 20. dakika T(11) olarak kayıt edildi. Bulgular: Çift lümenli endobronşiyal tüp kullanılan Grup 1'deki hastalarda SAB, DAB ve OAB değerleri T4, T5 ve T6 zamanlarında diğer gruptaki aynı zaman aralığındaki değerlerine göre anlamlı olarak yüksek bulundu. Her ne kadar KAH değerlerinde her iki grup arasında herhangi bir fark olmamasına rağmen çift lümenli entübasyon grubunda özellikle T4 döneminde anlamlı bir yükseklik bulundu. BİS açısından her iki grup arasında kaydedilen sonuçlarda istatistiksel olarak anlamlı farklılık gözlenmedi. SpO2 değerleri açısından her iki grup incelendiğinde anlamlı farklılığa rastlanmamasına rağmen çift lümenli gruptaki SpO2 değerleri hafif düşük tespit edildi. Sonuç: Çift lümenli tüp ile entübe edilen hastalarda hemodinamik yanıtın tek lümenli tüple entübe edilen hastalardaki hemodinamik yanıta göre daha belirgin olması, bu grup hastalarda indüksiyonda daha dikkatli davranılması gerektiği sonucuna vardık.
Özet (Çeviri)
Aim: In this study, we aimed to compare the effect of laryngoscopy and intubation on hemodynamic response during single lumen endotracheal and double lumen endobronchial tube in patients with enough depth of anesthesia by using bi-spectral indexes (BIS). Method: The patients were randomized into two groups prospectively. Each group had 41 patients. The patients were intubated by double lumen endobronchial intubation tube in Group 1 and in Group 2 patients were intubated by single lumen tube. The hemodynamic [(systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), and heart rate (HR)] responses of each groups, bi-spectral indexes (BIS) level, and peripheral oxygen saturation (SpO2) level were monitorised. All data were recorded before premedication (T1), before induction (T2), after induction, before intubation (T3), 1. min (T4), 3. min (T5), 5. min (T6), 7,5. min (T7), 10. min (T8), 12,5. min (T9), 15. min (T10), and 20. minutes (T11) after intubation. Result: The SAP, DAP and MAP results were significantly higher in double lumen endobronchial intubation tube group during T4, T5, and T6. Although there was no statistically difference between groups in terms of HR, in double lumen endobronchial intubation tube group statistically higher in T4 according to baseline level. When the groups were compared in terms of SpO2 and BIS, there were no significantly differences between the groups. Conclusion: Double-lumen tube intubation is significantly increased the haemodynamic response when compared the single-lumen tube intubation. Physicians should be consider the the this effect during intubation.
Benzer Tezler
- Çift lümenli tüp kullanılan hastalarda direk laringoskopi ve video laringoskopinin dQ-T aralığı, Tp-e aralığı ve Tp-e/dQ-T oranına etkisi
The effects of direct laryngoscopy and videolaryngoscopy in patients with double lumen tube, QTc interval, Tp-e interval and Tp-e/QTc ratio
MUSTAFA KADIOĞLU
- Çift lümenli tüp yerleştirilmesi için geleneksel Macintosh Bleyd, C-MAC Videolaringoskop ve yüksek açılı C-MAC D-bleyd'in kullanımının karşılaştırılması
A comparision of the use of the traditional macintosh blade, C-MAC Videolaryngoscope and high angle C-MAC D-blade for double lumen tube placement
ESRA YETİŞ
Tıpta Uzmanlık
Türkçe
2024
Necmettin Erbakan ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
Yükleniyor...
- Çift lümenli tüp ile entübasyon zorluğunun değerlendirilmesinde fotoğraf tabanlı yapay zeka algoritmalarının etkinliği ve güvenilirliği
Effectiveness and reliability of photo-based artificial intelligence algorithms in assessing double-lumen tube intubation difficulty
DENİZ SERİM KORKMAZ
Tıpta Uzmanlık
Türkçe
2025
Sağlık Bilimleri ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
Yükleniyor...
- Tek akciğer ventilasyonunda çift lümenli tüp yeri doğrulama tekniklerinin karşılaştırılması: Oskültasyon, fiberoptik bronkoskopi ve videolu çift lümenli tüp
Comparison of double lumen tube place confirmation techniques in single lung ventilation: Auscultation, fiberoptic bronchoscopy and video double lumen tube
ARZU FIRAT DURBİLMEZ
Tıpta Uzmanlık
Türkçe
2025
Sağlık Bilimleri ÜniversitesiAnestezi ve Reanimasyon Ana Bilim Dalı
Yükleniyor...
- Acil serviste endotrakeal entübasyon sağlanan olguda tek akciğer ventilasyonuna geçiş gerektiğinde acil tıp hekimlerinin endotrakeal tüp, modifiye endotrakeal tüp, EZ blokör, Uni blokör ve çift lümenli tüp ile sağlayacakları tek akciğer izolasyonuna yönelik prosedürlerin incelenmesi: Prospektif maket çalışması
Examination of the procedures for single lung isolation that emergency medicine physicians will provide with endotracheal tube, modified endotracheal tube, EZ blocker, Uni blocker and double lumen tube when it is necessary to switch to single lung ventilation in cases with endotracheal intubation in the emergency department: Prospective model study
KÜBRA TÜRKYILMAZ