Geri Dön

İzmir ili içme suyu dağıtım şebekesinin kuzey kaynaklarıyla beslenen kısmında yersinia enterocolitica ve aeromonas hydrophila aranması

Detection of yersinia enterocolitica and aeromonas hydrophila in various areas feeding with north springs of İzmir city drinking water distribution system

  1. Tez No: 114112
  2. Yazar: FİDAN CEYLANER ÖZDEMİR
  3. Danışmanlar: DOÇ. DR. RENGİN ELTEM
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyoloji, Biology
  6. Anahtar Kelimeler: Yersinia enterocolitica, Aeromonas hydrophila, Mikrobiyolojik kalite, İçme suyu, Yersinia enterocolitica, Aeromonas hydrophila, Microbiological quality, Drinking water
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 144

Özet

V ÖZET İZMİR İLİ İÇME SUYU DAĞITIM ŞEBEKESİNİN KUZEY KAYNAKLARIYLA BESLENEN KISMINDA Yersinia enterocolitica VE Aeromonas hydrophila ARANMASI ÖZDEMÎR CEYLANER, Fidan Yüksek Lisans Tezi, Biyoloji Bölümü Tez Yöneticisi: Doç.Dr. Rengin ELTEM Ekim 2001, 134 pages İzmir İli içme suyu şebekesinin kuzey kaynaklarıyla beslenen bölümündeki çeşitli semtlerden alınan toplam 380 su numunesinde Yersinia enterocolitica ve Aeromonas hydrophila aranmıştır. Bunun yanısıra toplam heterotrofik bakteri, toplam koliform ve fekal koliform sayıları belirlenerek, her bir içme suyu numunesinin kalıntı klor konsantrasyonları da saptanmıştır. Yersinia enterocolitica araştırılması iki aşamalı zenginleştirme yöntemi kullanılarak yapılmıştır. Seçici besiyeri olan“CİN Agar”kullanılarak izolasyon yapılmıştır. Aeromonas hydrophila izolasyonu için ise seçici besiyeri olan“Aeromonas Medium Base”kullanılmıştır. Elde edilen izolatların tanıları Bergey's Manual of Determinative Bacteriology (1984) ve Prokaryotes (1992)'e göre yapılmıştır. İncelenen numunelerden izole edilen 1 1 izolat Yersinia enterocolitica (% 3), 3 izolat Aeromonas hydrophila (% 0,8) olarak tanımlanmıştır içme suyu yönetmeliği göre 24 adet numune toplam heterotrofik bakteri sayısı ve 17 adet numune de toplam koliform sayısı standartlarının üstünde bulunmuştur. Bunlardan 3 adet numune her iki kriter açısından da standartlara uygun değildir. Uygulanan klor konsantrasyon aralığı 0,3-1,00 ppm. olarak belirlenmiştir. Genellikle klor miktarı yüksek olan bölgelerden alınan numunelerde içme suyu yönetmeliğine uygunluk gözlenmiştir.

Özet (Çeviri)

VII ABSTRACT DETECTION OF Yersinia enterocolitica AND Aeromonas hydrophila IN VARIOUS AREAS FEEDING WITH NORTH SPRINGS OF İZMİR CITY DRINKING WATER DISTRD3UTION SYSTEM ÖZDEMİR CEYLANER, Fidan Msc in Biology Department Supervisor: Assoc.Doc. Dr.Rengin ELTEM October, 2001, 134 pages In this study, Yersinia enterocolitica and Aeromonas hydrophila were searched in 380 water samples taken from various areas feeding with north springs of İzmir city drinking water distribution system. Also, total heterotrophic bacteria, total coliform, fekal coliform counts and free residual chlorine concentrations of each drinking water samples were determined. Yersinia enterocolitica reseach was done by using two step enrichment method. Isolation was carried out by using CIN agar, which is a selective medium. Aeromonas medium base, which is also a selective medium, was used for isolation of Aeromonas hydrophila. Identification of isolates was done according to Bergey's Manual of Determinative Bacteriology (1984) and Prokaryotes (1992) 1 1 of the isolates and 3 of the isolates from investigated samples were identified as Yersinia enterocolitica (3%) and Aeromonas hydrophila (0,8%), respectively. With respect to total heterothrophic bacteria and total coliform bacteria, 24 of 380 water samples and 17 of 380 water samples were not acceptable according to the Turkish Potable Water Regulation, respectively. In addition to these results, 3 of these water samples were not acceptable for both criteria. Residual chlorine concentration in distribution system were in the range of 0,3- 1,00 ppm. Generally, the samples taken from areas with high chlorine concentration were acceptable according to the Turkish Potable Water Regulation.

Benzer Tezler

  1. İzmir ili içme suyu dağıtım şebekesinin güney kaynaklarıyla beslenen kısmında yersinia enterocolitica ve aeromonas hydrophila aranması

    Detection of yersinia enterocolitica and aeromonas hydrophila in various areas feeding with south springs of İzmir city drinking water distribution system

    BEKİR TOPÇU

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Çevre MühendisliğiEge Üniversitesi

    Çevre Bilimleri Ana Bilim Dalı

    DOÇ.DR. RENGİN ELTEM

  2. İzmir içmesuyu ana dağıtım sistemini besleyen kuyuların hidrolik ve hidrolojik özellikleri bakımından incelenmesi

    The assesment of hydraulic and hydrologic characteristics of wells Izmir main water distribution system

    YETER ERTEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    İnşaat MühendisliğiDokuz Eylül Üniversitesi

    İnşaat Mühendisliği Bölümü

    YRD. DOÇ. AHMET ALKAN

  3. İzmir ili içme ve kullanma suyu temininde mevcut durum analizi ve uzun dönem planlaması

    Drinking water condition of Izmir province and long-term planning

    SİNEM KANBEROĞLU TELEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    İnşaat MühendisliğiEge Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÖMER LEVEND AŞIKOĞLU

  4. İzmir ili içme ve kullanım sularında radyoaktivite ve veriler arasında korelasyon analizleri

    Başlık çevirisi yok

    MÜSLÜM MURAT SAÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    Nükleer MühendislikEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DOÇ.DR. MEHMET N. KUMRU

  5. Assessment of critical infrastructure protection: A case study from urban drinking water system

    Kritik altyapı güvenliğinin değerlendirilmesi: Kentsel içme Suyu sistemi örneği

    FULDEN ESKİCİOĞLU TUNGER

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Çevre MühendisliğiDokuz Eylül Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ORHAN GÜNDÜZ