Amonyak-su (NH3-H2O) karışımlı absorbsiyonlu soğutma sistemleri ve termodinamik analizi

Ammonia-water refrigerant based absorption cooling systems and their thermodynamic analysis

  1. Tez No: 114486
  2. Yazar: RIZA GÖNÜLAL
  3. Danışmanlar: YRD. DOÇ. DR. HAKAN YAVUZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Performans katsayısı, işlerlik etkinliği, soğutma tesir katsayısı, Amonyak-su, Soğurmalı soğutma sistemleri, Soğutma sistemleri, Soğutma suyu, Termodinamik analiz, Coefficient of performance, effectiveness, impression of coefficient to cool, Ammonia-water, Absorption cooling systems, Cooling systems, Cooling water, Thermodynamic analysis
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Mustafa Kemal Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Bu çalışmada; soğutma sistemlerine genel bir giriş ile soğurmalı soğutma sistemleri hakkında verilen detaylı bilginin ardından, soğurmalı soğutma sistemlerinin termodinamik analizi yapılarak, sistem performansını (soğutma tesir katsayısı) etkileyen parametrelerin sıcaklıkla değişimleri incelenmiştir. Soğurmalı soğutma sistemleri, mekanik enerjiye en az gereksinim duyulan, bununla birlikte sistemin çok büyük miktarlarda ısı enerjisi gerektirdiği sistemleridir. Genel olarak bu sistemler; yoğuşturucu, buharlaştırıcı, soğurucu, sirkülasyon pompası, genleşme valileri ile karışım ısı değiştirgeçlerinden meydana gelmektedir. Absorbsiyonlu soğutma sistemlerinin yapılan analizinde karışım akışkan ve soğutucu akışkan ısı değiştirgeçlerinin karşıt akışlı oldukları kabul edilerek; ısı değiştiricilerinin performans katsayıları hesaplanarak, akışkan çıkış sıcaklıkları belirlenmiştir. Yoğuşturucu ve soğurucudan çekilerek çevreye atılan ısıların kullanılmadığı varsayımı neticesinde bu ısıların enerjileri ihmal edilmiştir. Karışım akışkanın; buharlaştırıcı çıkışında buhar fazında ve evaporatör sıcaklığında, ayırıcı çıkışında ise yine buhar faz ve ayırıcı sıcaklığında olduğu varsayılarak, ayırıcı çıkışındaki, soğutucu kütlesel konsantrasyonun 0.99 olduğu kabul edilmiştir. Ayrıca sistemdeki her noktanın entalpi değerleri bulunarak, her noktadaki soğutucu akışkanın içinde bulunduğu faz belirlenmek sureti ile, sistemin soğutma tesir katsayısı belirlenmiştir. Genişleme vanalarındaki exerji kayıplarının olmadığı varsayılarak sistemin performans katsayısı, sirkülasyon oramda incelenmiştir. Sistemin analizi esnasında basınç kayıp değerleri hesaplamalarında; literatür bağıntıları göz önünde bulundurulmuştur. 2001, 75 Sayfa.

Özet (Çeviri)

ABSTRACT In this work; after a general review of refrigeration systems, a detailed background information on absorbtion refrigeration systems are provided which is followed by thier thermodynamic analysis and irreversibilities on thermal processes effecting system performances. Absorbsional refrigeration systems, requring small amount of mechanical energy, need much more heat energy than mechanical energy. In general, these systems consist of a generator, condenser, evaporator, absorber, circulation pump, throttle valve with mixture and refrigerant heat exchangers. In the analysis; heat exchanges of mixture and refrigerant fluids enter in the opposite ends of heat exchangers and flow through in opposite directions as assumed. Using calculate heat exchange coefficient of performance values, fluid outlet temperatures are determined. It is assumed that amount of heat extracted from the condenser and absorber is not used and the exergy of heat exchange with environment is neglected for these components. Both at the evaporator and generator outlet the mixture is in vapour phase a assumed,so the mixture is at evaporator and generator temperatue respectively. Moreover, it is assumed that the refrigerant mass consantration at the generator outlet is 0.999. In addition, the determination of entalphies for all the specific points of the systems and the state of the fluid are used in calculation of the Coefficient of Performance (COP). No throttle valve exergy loss assumption makes a little bit easier to calculate system coefficient of performance, circulation ratio, exergetic coefficient of performance and total exergy loss of system. Given literature relations are used to calculate pressure drops in the pipes. 2001, 75 Pages

Benzer Tezler

  1. Parabolik oluklu güneş kollektörü destekli çift etkili absorbsiyonlu soğutma sisteminin termodinamik analizi

    Thermodynamic analysis of a parabolic trough solar collector supported double effect absorption refrigeration system

    HAKAN BALDAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Makine MühendisliğiMersin Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FATİH ÜNAL

  2. NH3 için önerilen yeni bir gerçek gaz hal denklemi ve bu hal denklemi ile bazı moleküler-fiziksel özelliklerin saptanması

    Başlık çevirisi yok

    MERAL HOŞCAN

    Doktora

    Türkçe

    Türkçe

    1984

    KimyaGazi Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. ETHEM KİŞİOĞLU

  3. Ankara ili Gölbaşı ilçesi köyleri içme ve kullanma suyu temini üzerinde bir araştırma

    A Research on rural domestic water supplies in the villages of Gölbaşı district of Ankara

    NEŞE KADIOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Halk SağlığıAnkara Üniversitesi

    Kültürteknik Ana Bilim Dalı

    YRD. DOÇ. DR. OSMAN YILDIRIM

  4. Farklı kükürt giderme yöntemlerinin çeşitli Türk linyitlerine uygulanması

    Başlık çevirisi yok

    SADRİYE KÜÇÜKBAYRAK

    Doktora

    Türkçe

    Türkçe

    1984

    Kimya Mühendisliğiİstanbul Teknik Üniversitesi

    PROF. DR. ENİS KADIOĞLU