Çift devreli enerji iletim hatlarında mesafe koruma sisteminin analizi

Analysis of distance protection system of double circuit line in power system

  1. Tez No: 114655
  2. Yazar: Ş. YALIN ÇEKEN
  3. Danışmanlar: PROF. DR. M. SEZAİ DİNÇER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Çift devreli paralel enerji iletim hattı, mesafe korum, rölesi, Enerji iletim hatları, Mesafe rölesi, Double Circuit Power Transmission Line, parallel operation, distance relay Number of Pages : 58 Advisor : Prof. Dr. M.Sezai DİNÇER, Energy transmission lines, Distance relay
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÇİFT DEVRELİ ENERJİ İLETİM HATLARINDA MESAFE KORUMA SİSTEMİNİN ANALİZİ (Yüksek Lisans Tezi) Ş. YALIN ÇEKEN GAZİ ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ Aralık 2001 ÖZET Bir enerji şebekesinde jeneratör veya hatların devreden çıkması ya da yük veya üretimdeki değişimlerin yarattığı etkiler mesafe koruma rölelerinin performanslarını etkileyebilmektedir. Bir mesafe koruma rölesinin çift devreli bir hattın herhangi bir fazının korumasını gerçekleştirdiği durumda çift devreli hattın işletme durumu önem kazanmaktadır. Ortaya konulan simülasyonlarda. mesafe koruma rölesinin hattın %75 ila %100'ünü koruduğu durumda faz- toprak arızasında çift devreli bir hatta (genellikle aynı direk üzerinde taşınmaktadır) nasıl bir durum ortaya çıkarttığı gösterilmeye çalışılmaktadır. Bu çalışmada çift devreli bir hattaki arızalar modellenmiş, analiz edilmiş v< belirli formüller üretilmiştir. Uygulama sadece faz-toprak arızası içiı uygulanmış ve sonuçlar çıkartılmıştır. Bilim Kodu : 608.02.07

Özet (Çeviri)

ANALYSIS OF DISTANCE PROTECTION SYSTEM OF DOUBLE CIRCUIT LINE IN POWER SYSTEM (M.Sc. Thesis) Ş. YALIN ÇEKEN GAZİ UNIVERSITY INSTITUTE OF SCIENCE AND TECHNOLOGY December 2001 ABSTRACT Due to changes in the power system, such as geerator and line outages and changes in load and generation, the performance of distance relays can vary. In the case of a distance relay protecting a phase of a double-circuit line, especially the state of the parallel circuit is of major importance. The resulting simulations show that relating to the power system state, a distance relay can cover from less than %75 up to far more than %100 of the total line length. The distance protection of a double circuit line under various line fault condition is assumed and formulated. The results are only taken from single line fault condition. Science Code : 608.0207

Benzer Tezler

  1. Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması

    Başlık çevirisi yok

    EMEL ÖNDER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Matris lie grupları üzerine

    Başlık çevirisi yok

    RIFAT GÜNEŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İnönü Üniversitesi

    Matematik Ana Bilim Dalı

    Yükleniyor...

  3. NaI (TI) dedektörleri için toplam verim ve tüm enerji pik duyarlığının Monte Carlo metodu ile elde edilmesi

    Başlık çevirisi yok

    N. REMZİYE ERGÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  4. Regresyon analizi ve Türkiye üzerine bir deneme buğday üretiminin tahmini

    Başlık çevirisi yok

    MACİT MESUT ÖZMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...