Farklı SPECT (bilgisayarlı tek foton emisyon tomografisi) sistemlerinden elde edilen tomografik görüntü parametrelerinin standart yazılım (PIP) kullanılarak karşılaştırılması

Comparison of tomographic image parameters with a standard software (PIP) obtained from different SPECT (single photon emission computed tomography) systems

  1. Tez No: 120941
  2. Yazar: TÜRKAY TOKLU
  3. Danışmanlar: PROF. DR. DOĞAN BOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2002
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 66

Özet

ÖZET Yüksek Lisans Tezi FARKLI SPECT (BİLGİSAYARLI TEK FOTON EMİSYON TOMOGRAFİSİ) SİSTEMLERİNDEN ELDE EDİLEN TOMOGRAFİK GÖRÜNTÜ PARAMETRELERİNİN STANDART YAZILIM (PIP) KULLANILARAK KARŞILAŞTIRILMASI Türkay TOKLU Ankara Üniversitesi Fen Bilimleri Enstitüsü Fizik Mühendisliği Anabilim Dalı Danışman : Prof. Dr. Doğan BOR SPECT sistemleri, Nükleer Tıp uygulamalarında kullanılan en önemli araçlardan biri olmaya başlamıştır. Bu sistemlerde planar performans kontrollerine ek olarak rutin tomografik performans kontrollerinin yapılması bir zorunluluktur. Planar sistemlerin kalite kontrolü ve performans testleri için kabul edilmiş yöntem ve referans değerler bulunmasına rağmen, SPECT için kullanılabilen sınırlı sayıda yöntem ve bazı topluluklar tarafından önerilmiş teknikler bulunmaktadır. Bu çalışmanın amacı, SPECT sistemlerinin bazı tomografik görüntü parametrelerini ölçmek ve bu parametreleri sistem bilgisayarlarıyla olduğu gibi standart bir yazılım paketi kullanarak karşılaştırmaktır. Düzenli kalite kontrol çalışmalarının da bu parametreler üzerindeki etkileri araştırılmıştır. Değerlendirme için 4 farklı üreticiye ait 11 farklı modelde, 25 detektör kullanılmıştır. Birden çok detektörlü SPECT sistemlerinin her detektörü birbirinden bağımsız olarak değerlendirilmiştir. Görüntü parametrelerinin karşılaştırılmasında standart yazılım olarak PIP (Portable Image Processing) V 5.2 kullanılmıştır. Sistemler, planar ve tomografik ayırma gücü, tomografik homojenite, % RMS gürültü ve kontrast parametrelerine değerlendirilmiştir. Parametrelerin standart, yazılımla değerlendirilmesinde sistem yazılımlarıyla maksimum %' 13,96'lık farklılık saptanmıştır. Sistemlerin kararlılığının, düzenli kalite kontrol çalışmaları kadar görüntü parametreleri üzerinde etkili olduğu belirlenmiştir. 2002, 54 sayfa ANAHTAR KELİMELER : Nükleer Tıp, tomografi, kalite kontrolü, ayırma gücü, homojenite, gürültü, kontrast

Özet (Çeviri)

ABSTRACT Master Thesis COMPARISON OF TOMOGRAPHIC IMAGE PARAMETERS WITH A STANDART SOFTWARE (PIP) OBTAINED FROM DIFFERENT SPECT (SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY) SYSTEMS Türkay TOKLU Ankara University Graduate School of Natural and Applied Sciences Department of Engineering Physics Supervisor : Prof. Dr. Doğan BOR SPECT systems are started to be one of the most important tool of Nuclear Medicine applications. In addition to planar performance, it is mandatory to make routine tomographic performance checks on these systems. Although there are well- accepted methods and reference values for quality control and performance testing of planar systems, there are only few standard techniques that can be used for SPECT and some specific methods recommended by some advisory bodies. The aim of this study was to measure some tomographic image parameters of SPECT systems, and compare these parameters using system computers as well as a standard software. Effects of routine quality control studies on these parameters were also investigated. 25 detectors belonging to 4 different vendors and 1 1 different models were used for the evaluation. Each detector of multi-head SPECT systems was evaluated individually. Comparison of image parameters was performed using PIP (Portable Image Processing) V 5.2 as standard software. Systems were evaluated in terms of planar and tomographic resolution, tomographic uniformity, percent RMS noise and contrast. Maximum variation of 13,96 % was found in the evaluation of these parameters using standard software. It was determined that system stability affects image parameters as much as regular quality control studies. 2002, 54 pages Key Words : Nuclear Medicine, tomography, quality control, resolution, uniformity, noise, contrast 11

Benzer Tezler

  1. Birleşik bilgisayarlı tek foton emisyon tomografisi/bilgisayarlı tomografi (SPECT/CT) ile birleşik pozitron emisyon tomografisi/bilgisayarlı tomografi (PET/CT) sistemlerinde tomografik görüntülere sistem yazılım parametrelerinin etkisinin incelenmesi

    Investigation of the system software parameters effects on the tomographic images in the combined single photon emission computed tomography/ computed tomography (SPECT/CT) and combined positron emission tomography/ computed tomography (PET/CT) systems

    HIKMAT OSMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Radyoloji ve Nükleer TıpAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. TURAN OLĞAR

  2. Synthesis of dye-conjugated PD-L1 targeted peptides for use in pet/ct in diagnosis of lung cancer

    Akciğer kanseri teşhisi için PET/CT sistemlerinde kullanılacak PD-L1 proteini hedefli boya takılı peptitlerin sentezi

    SAADET YEŞİLMEN

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Biyokimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. ONUR ALPTÜRK

    DR. ÖZGÜR YILMAZ

  3. Sintilasyon NaI(TL) ve yarı iletken CdZnTe dedektörlü gama kameraların performans karakteristiklerinin karşılaştırılması

    Performance comparasin of gamma cameras of semiconductor CdZnTe and scintilator Nal(TI) dedectors

    ARMAĞAN AYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Fizik ve Fizik Mühendisliğiİstanbul Aydın Üniversitesi

    Sağlık Fiziği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FÜSUN ÇETİN

    PROF. DR. MUSTAFA DEMİR

  4. Görüntü füzyonu yöntemleri ile karaciğer lezyon görüntülerinin değerlendirilmesi

    Evaluation of liver lesion images with image fusion methods

    SAİM ERVURAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Elektrik ve Elektronik MühendisliğiSelçuk Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. MURAT CEYLAN

  5. Farklı biyomedikal görüntüleme sistemlerinde radyasyon doz çalışması

    Radiation dose study in different medical imaging systems

    OSMAN GÜNAY

    Doktora

    Türkçe

    Türkçe

    2022

    BiyomühendislikKocaeli Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. ÖZCAN GÜNDOĞDU