Sintilasyon NaI(TL) ve yarı iletken CdZnTe dedektörlü gama kameraların performans karakteristiklerinin karşılaştırılması

Performance comparasin of gamma cameras of semiconductor CdZnTe and scintilator Nal(TI) dedectors

  1. Tez No: 664889
  2. Yazar: ARMAĞAN AYDIN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ FÜSUN ÇETİN, PROF. DR. MUSTAFA DEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 121

Özet

Nükleer Tıp görüntüleme teknikleri, başta Onkoloji ve Kardiyoloji olmak üzere bir çok klinik alanda yaygın olarak kullanılmaktadır. Tek Foton Emisyon Bilgisayarlı Tomografisi (SPECT) ve Pozitron Emisyon Tomografisi (PET) bu alanda kullanılan temel görüntüleme yöntemleridir. Nükleer tıpta kullanılan görüntüleme sistemlerinin başında, düzlemsel görüntüleme ve SPECT yapabilen Gama Kameralar yer almaktadır. Gama Kameralar tek başına (SPECT) veya hibrid sistemlerde Bilgisayarlı Tomografi ve PET cihazlarıyla birlikte (SPECT/BT, SPECT/PET) yaygın olarak kullanılmaktadır. Hedef organ tarafından tutulan radyofarmasotikler radyasyon dedektörlerinin algılayabileceği γ-ışınları yaymakta ve Gama kamera dedektörü yardımıyla radyofarmasötiğin dokulardaki konuma ve zamana bağlı dağılımı belirlenmektedir. Bu radyoaktif dağılıma ilişkin farklı doğrultularda alınan projeksiyonlar bilgisayar ortamında üç boyutlu görüntülere dönüştürülebilmekte; düzlemsel ya da kesitsel, statik ya da dinamik görüntüler elde edilebilmektedir. . Gama Kamera performansını betimleyen en önemli karakteristikler uzaysal çözünürlük, lineerite, enerji çözünürlüğü, dedektör verimi (sensitivitesi) ve sayım hızı performansıdır. Gama Kamera performansı dedektörün performansına güçlü bir biçimde bağlı olduğundan dedektörün türü ve özellikleri görüntü kalitesi ni önemli ölçüde etkilemektedir. Konvansiyonel Gama Kameralarda ağırlıklı olarak Talyum katkılı Sodyum İyodor NaI(Tl) sintilasyon dedektörler kullanılmaktadır. Ancak son yıllarda yarıiletken dedektör teknolojisindeki gelişmelerin sonucu olarak enerji rezolüsyonu, uzaysal rezolüsyonu ve hassasiyeti daha yüksek olan CdTe ve CdZnTe gibi yarıiletkenlerin dedektör malzemesi olarak kullanıldığı yarıiletken dedektörlü Gama kameralar sintilasyon krietalli Gama kameralara göre alternatif olarak belirmiştir. Artık yarı iletken dedektörlü gama kameraların da görüntüleme merkezlerinde kullanımı artmaktadır. Bu çalışmada , İstanbul Üniversitesi Tıp Fakültesi, Nükleer Tıp Anabilim Dalı'nda bulunan CdZnTe yarıiletken dedektörlü gama kamera ile NaI (Tl) sintilasyon dedektörlü gama kameraların enerji rezolüsyonu, uzaysal rezolüsyonu, verimi ve lineeritesi gibi temel performans karakteristikleri 140 keV Tc-99m radyoizotopu kullanılarak belirlenmiştir. Elde edilen soouçlar kullanılarak yarıiletken ve sintilasyon dedektörlü gama kameraların performans karşılaştırması yapılmıştır. Sonuçlar yarı iletken dedektörlü gama kameraların sintilasyon dedektörlü gama kameralara göre özellikle yüksek uzaysal rezolüsyon ve enerji rezolüsyonu sağladığı, aynı zamanda sayım hassasiyetinin de yüksek olduğu tespit edilmiştir. Bu sonuçlar literatürde elde edilen sonuçlarla uyum içerisindedir.

Özet (Çeviri)

Nuclear Medicine imaging techniques are widely used in various clinical areas, especially in Oncology and Cardiology. Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are main imaging methods used in this area. Gamma cameras capable of planer imaging and SPECT are major imaging system used in Nuclear Medicine. Gamma Cameras are widely used as single (SPECT) or together with Computed Tomography and PET devices (SPECT / CT, SPECT / PET) in hybrid systems. Radiopharmaceuticals localized in the target organ emit γ-rays that can be detected by radiation detectors and the distribution of the radiopharmaceutical in the tissues is determined by means of gamma camera detector depending on the location and time. Projections taken in different directions is converted to three-dimensional images in computer environment. Planar or cross-sectional, static or dynamic images can be obtained by using these radioactivity distributions. The most important characteristics decribing Gamma Camera performance are spatial resolution, linearity, energy resolution, detector efficiency (sensitivity) and count rate performance. Since gamma camera performance is strongly dependent on detector performance, detector type and characteristics strongly affect the image quality. Conventional Gamma Cameras mostly use NaI (Tl) scintillation detectors. As a result of the developments in semiconductor detector technology in recent years, gamma cameras with CdTe or CdZnTe semiconductor dedectors having higher energy resolution, spatial resolution and sensitivity, have emerged as an alternative to gamma cameras with scintillation dedector. Currently, use of semiconductor gama cameras in imaging centers is rapidly increasing. In this study, main performance characteristics such as energy resolution, spatial resolution, efficiency and linearity are determined for two different type gamma cameras with CdZnTe semiconductor detector and NaI (Tl) scintillation detector at the Department of Nuclear Medicine of Istanbul University Medicine Faculty by using Tc-99m radioisotope with 140 keV energy. By examining obtained results, performances of gamma cameras with CdZnTe semiconductor dedector and the gamma camera with NAI(Tl) scintillation detector are compared. It is seen that the gama camera with CdZnTe semiconductor have higher spatial and energy resolutions and higher detector sensivity compared to the gama camera with NaI (Tl) scintillation detector. These results are in agreement with the results in the literature.

Benzer Tezler

  1. Naı(Tl), labr3(CE) sintilasyon ve cdznte yarıiletken dedektörler ile ortam doz eşdeğeri hızı belirlenmesi için gama-ışını spektrumundan G(E) fonksiyonu ile doza dönüşüm amaçlı optimizasyon algoritması geliştirilmesi

    Development of an optimization algorithm for dose conversion from gamma-ray spectrum using g(e) function to estimate ambient dose equivalent rate with nai(Tl), labr3(CE) scintillation and cdznte semiconductor detectors

    NESLİHAN CEREN KAPLAN ERDEM

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. HALUK YÜCEL

    DOÇ. DR. GAZİ ERKAN BOSTANCI

  2. CdTe ve NaI(Tl) dedektörlerinin çift enerji yöntemi ile sinyal gürültü oranlarının (SNR) karşılaştırılması

    Comparison of signal to noise ratios (SNR) of CdTe and NaI(Tl) detectors with using dual-energy method

    TİMUÇİN DİPÇİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET BAYBURT

  3. İzmir'de organik ve geleneksel tarım alanlarındaki toprak ve bitki örneklerinde bazı radyonüklidlerin belirlenmesi

    Determination of some radionuclides in soil and plant samples in the field of organic and conventional farming in Izmir

    MEHMET BAKIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Nükleer MühendislikEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DOÇ. DR. AYSUN UĞUR GÖRGÜN

  4. Bazı ince filmlerin sentezi, radyasyon geçirgenliği, antibiyotik giderim ve antimikrobiyal özelliklerinin incelenmesi

    Synthesis of some thin films; investigation of their radiation shielding, antibiotic degradation and antimicrobial properties

    MUSTAFA KAVGACI

    Doktora

    Türkçe

    Türkçe

    2022

    Fizik ve Fizik MühendisliğiKahramanmaraş Sütçü İmam Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. ADNAN KÜÇÜKÖNDER

    DOÇ. DR. SÜLEYMAN KERLİ

  5. Radyasyondan korunmak için tungsten oksit-polimer kompozitlerinin hazırlanması gama ışınlarını tutma ve termal özelliklerinin incelenmesi

    Preparation and Investigation of Tungsten oxide-polymer Composites for Gamma radiation Shielding and Thermal properties

    BERNA KÖRPINAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Polimer Bilim ve TeknolojisiEge Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. HAKAN AKAT