Sintilasyon NaI(TL) ve yarı iletken CdZnTe dedektörlü gama kameraların performans karakteristiklerinin karşılaştırılması

Performance comparasin of gamma cameras of semiconductor CdZnTe and scintilator Nal(TI) dedectors

  1. Tez No: 664889
  2. Yazar: ARMAĞAN AYDIN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ FÜSUN ÇETİN, PROF. DR. MUSTAFA DEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Fizik ve Fizik Mühendisliği, Radiology and Nuclear Medicine, Physics and Physics Engineering
  6. Anahtar Kelimeler: Dedektörler, Gama kameralar, Görsel performans, Kadmiyum, Kamera, Performans, Talyum, Detectors, Gamma cameras, Visual performance, Cadmium, Camera, Performance, Thallium
  7. Yıl: 2020
  8. Dil: Türkçe
  9. Üniversite: İstanbul Aydın Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Nükleer Tıp görüntüleme teknikleri, başta Onkoloji ve Kardiyoloji olmak üzere bir çok klinik alanda yaygın olarak kullanılmaktadır. Tek Foton Emisyon Bilgisayarlı Tomografisi (SPECT) ve Pozitron Emisyon Tomografisi (PET) bu alanda kullanılan temel görüntüleme yöntemleridir. Nükleer tıpta kullanılan görüntüleme sistemlerinin başında, düzlemsel görüntüleme ve SPECT yapabilen Gama Kameralar yer almaktadır. Gama Kameralar tek başına (SPECT) veya hibrid sistemlerde Bilgisayarlı Tomografi ve PET cihazlarıyla birlikte (SPECT/BT, SPECT/PET) yaygın olarak kullanılmaktadır. Hedef organ tarafından tutulan radyofarmasotikler radyasyon dedektörlerinin algılayabileceği γ-ışınları yaymakta ve Gama kamera dedektörü yardımıyla radyofarmasötiğin dokulardaki konuma ve zamana bağlı dağılımı belirlenmektedir. Bu radyoaktif dağılıma ilişkin farklı doğrultularda alınan projeksiyonlar bilgisayar ortamında üç boyutlu görüntülere dönüştürülebilmekte; düzlemsel ya da kesitsel, statik ya da dinamik görüntüler elde edilebilmektedir. . Gama Kamera performansını betimleyen en önemli karakteristikler uzaysal çözünürlük, lineerite, enerji çözünürlüğü, dedektör verimi (sensitivitesi) ve sayım hızı performansıdır. Gama Kamera performansı dedektörün performansına güçlü bir biçimde bağlı olduğundan dedektörün türü ve özellikleri görüntü kalitesi ni önemli ölçüde etkilemektedir. Konvansiyonel Gama Kameralarda ağırlıklı olarak Talyum katkılı Sodyum İyodor NaI(Tl) sintilasyon dedektörler kullanılmaktadır. Ancak son yıllarda yarıiletken dedektör teknolojisindeki gelişmelerin sonucu olarak enerji rezolüsyonu, uzaysal rezolüsyonu ve hassasiyeti daha yüksek olan CdTe ve CdZnTe gibi yarıiletkenlerin dedektör malzemesi olarak kullanıldığı yarıiletken dedektörlü Gama kameralar sintilasyon krietalli Gama kameralara göre alternatif olarak belirmiştir. Artık yarı iletken dedektörlü gama kameraların da görüntüleme merkezlerinde kullanımı artmaktadır. Bu çalışmada , İstanbul Üniversitesi Tıp Fakültesi, Nükleer Tıp Anabilim Dalı'nda bulunan CdZnTe yarıiletken dedektörlü gama kamera ile NaI (Tl) sintilasyon dedektörlü gama kameraların enerji rezolüsyonu, uzaysal rezolüsyonu, verimi ve lineeritesi gibi temel performans karakteristikleri 140 keV Tc-99m radyoizotopu kullanılarak belirlenmiştir. Elde edilen soouçlar kullanılarak yarıiletken ve sintilasyon dedektörlü gama kameraların performans karşılaştırması yapılmıştır. Sonuçlar yarı iletken dedektörlü gama kameraların sintilasyon dedektörlü gama kameralara göre özellikle yüksek uzaysal rezolüsyon ve enerji rezolüsyonu sağladığı, aynı zamanda sayım hassasiyetinin de yüksek olduğu tespit edilmiştir. Bu sonuçlar literatürde elde edilen sonuçlarla uyum içerisindedir.

Özet (Çeviri)

Nuclear Medicine imaging techniques are widely used in various clinical areas, especially in Oncology and Cardiology. Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are main imaging methods used in this area. Gamma cameras capable of planer imaging and SPECT are major imaging system used in Nuclear Medicine. Gamma Cameras are widely used as single (SPECT) or together with Computed Tomography and PET devices (SPECT / CT, SPECT / PET) in hybrid systems. Radiopharmaceuticals localized in the target organ emit γ-rays that can be detected by radiation detectors and the distribution of the radiopharmaceutical in the tissues is determined by means of gamma camera detector depending on the location and time. Projections taken in different directions is converted to three-dimensional images in computer environment. Planar or cross-sectional, static or dynamic images can be obtained by using these radioactivity distributions. The most important characteristics decribing Gamma Camera performance are spatial resolution, linearity, energy resolution, detector efficiency (sensitivity) and count rate performance. Since gamma camera performance is strongly dependent on detector performance, detector type and characteristics strongly affect the image quality. Conventional Gamma Cameras mostly use NaI (Tl) scintillation detectors. As a result of the developments in semiconductor detector technology in recent years, gamma cameras with CdTe or CdZnTe semiconductor dedectors having higher energy resolution, spatial resolution and sensitivity, have emerged as an alternative to gamma cameras with scintillation dedector. Currently, use of semiconductor gama cameras in imaging centers is rapidly increasing. In this study, main performance characteristics such as energy resolution, spatial resolution, efficiency and linearity are determined for two different type gamma cameras with CdZnTe semiconductor detector and NaI (Tl) scintillation detector at the Department of Nuclear Medicine of Istanbul University Medicine Faculty by using Tc-99m radioisotope with 140 keV energy. By examining obtained results, performances of gamma cameras with CdZnTe semiconductor dedector and the gamma camera with NAI(Tl) scintillation detector are compared. It is seen that the gama camera with CdZnTe semiconductor have higher spatial and energy resolutions and higher detector sensivity compared to the gama camera with NaI (Tl) scintillation detector. These results are in agreement with the results in the literature.

Benzer Tezler

  1. Bitki koruma ilaçlarının çevreye etkisinin nükleer yöntemlerle araştırılması

    Research on the behaviour of the pesticide in the environmont by nuclear techniques

    KIYMET GÖZEK

    Doktora

    Türkçe

    Türkçe

    1987

    Çevre MühendisliğiAnkara Üniversitesi

    DOÇ. DR. YÜKSEL SARIKAYA

  2. Computer-aided analysis of mine drainage systems

    Başlık çevirisi yok

    MURTAZA YILMAZ

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Maden Mühendisliği ve MadencilikOrta Doğu Teknik Üniversitesi

    DOÇ. DR. ABDURRAHİM ÖZGENOĞLU

  3. Computerization of a classical scintillation gamma-ray spectrometer

    Başlık çevirisi yok

    FARSHİD MANOOCHEHRİ

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Nükleer MühendislikOrta Doğu Teknik Üniversitesi

    DOÇ. DR. F. ESEN ÖZSAN

  4. Gamma ray attenuation in soil

    Toprakta gama ışın soğurması

    FERHAN ÖZEŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    1989

    Nükleer MühendislikOrta Doğu Teknik Üniversitesi

    DOÇ.DR. TÜLAY YEŞİN