Düşük miliamper bilgisayarlı tomografinin vücut yağ dağılımının değerlendirmedeki yeri

Usage of low dose (low milliampers) CT in evaluation of body fat distribution

  1. Tez No: 131945
  2. Yazar: ADEVİYE GÖKOĞLU
  3. Danışmanlar: PROF. DR. O. MACİT ARIYÜREK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Bilgisayarlı tomografi, yağ alanı, yağ dağılımı, düşük doz, Computed tomography scanner, X-ray, fat area, fat distribution, low dose
  7. Yıl: 2003
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 97

Özet

Ill ÖZET Gökoğlu A, Düşük miliamper bilgisayarlı tomografinin vücut yağ dağılımını değerlendirmedeki yeri, Hacettepe Üniversitesi Tıp Fakültesi, Radyoloji Tezi, Ankara, 2003. Amacımız bilgisayarlı tomografi (BT) çekimi sırasında miliamper değerini düşürüp dozu azaltmak ve düşük doz BT'nin vücut yağ alanı ölçümündeki yerini değerlendirmekti. Çalışmaya uykuda solunum durması tanısı almış ve horlama şikayeti olan 18 yaşından büyük 68 hasta dahil edildi. Hastalardan standart dozla toraks, abdomen, üst ve alt ekstremiteden geçen kesitler alınmasını takiben, miliamper değeri standart dozun beşte birine indirilerek düşük dozla ek kesitler alındı. Miliamper saniye (mAs) dışındaki diğer tarama parametreleri sabit tutuldu. Hastalardan alınan ek kesit sayısı en fazla 3'tü ve hastaların aldıkları ek doz standart dozun %5'inden azdı. Düşük doz ve standart dozla elde edilen görüntüler bir monitöre aktarıldıktan sonra otomatik ölçüm yapabilme özellikleri kullanılarak yağ alanı hesaplandı. Bu çalışmada yağ dansitesi ölçümleri -40 ve -140 HU aralıklarında yapıldı. Abdomen ve torakstan yapılan ölçümlerde total, viseral ve subkutan yağ alanları ayrı ayrı ölçüldü. Aynı bölgeden 2 farklı BT dozu ile elde edilen görüntülerde yağ alanı ölçümleri arasındaki fark iki eş grup arasındaki farkın önemlilik testi ile araştırıldı. Anlamlılık sınırı olarak p0.05). Düşük doz BT ile hesaplanan yağ alanları standart doz BT ile hesaplanan alanlardan düşüktür ve aradaki fark istatistiksel olarak anlamlıdır. Düşük doz ve standart doz BT ile yapılan ölçümler arasındaki bu fark, mAs'nin dolayısıyla da dozun azalmasına bağlı olarak gürültünün artmasından kaynaklanmaktadır. Toraks viseral yağ alanı ve üst ekstremiteden yapılan ölçümlerde istatistiksel olarak anlamlı fark olmaması ise bu bölgelerdeki yağ miktarının çok az olmasına bağlandı.

Özet (Çeviri)

IV ABSTRACT Gökoğlu A, Usage of low dose (low milliamperes) CT in evaluation of body fat distribution. Medical Faculty of Hacettepe University, Ankara, 2003. We aimed to reduce the dose by decreasing miliamper value in CT scanning and to evaluate the importance of low dose CT in body fat proportion measurement. In this study we included 68 patients who were diagnosed sleep apne or who had snore symptoms and older than 18 years. Following standart dose CT scanning of thorax, abdomen, upper and lower extremities, additional slices were scanned by decreasing the mAs values to 1/5 of standart dose. The other scanning parameters (excluded mAs) were not changed. Additional slices were not more than 3 and additional doses that patients have been taken, were 5% lower than the standart dose. Low dose and standart dose CT imagining were recorded, and fat area was calculated by using automatic measurement features. In this study, measurement of fat density is made between -40 and -140 HU. In abdomen and thorax CT, total, visceral and subcutaneous fat is measured one by one. In CT imagining of the same area with different doses, the difference between fat area measurements are examined by using t test for paired samples. p0.05). Fat area measurements with low dose CT were lower than the fat area measurements with standart dose CT and differences are statistically significant. Diferences in measurements between low dose and standart dose CT is the result of increased noise by decreasing mAs. Having no statistically significant difference in fat area measurements in visceral thorax and upper extremities CT is caused from having minimal fat quantity in these regions.

Benzer Tezler

  1. Akciğer kitlelerinin görüntülenmesinde düşük doz bilgisayarli tomografinin rolü

    The role of low dose computed tomography in screening of pulmonary masses

    DERYA DEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Radyoloji ve Nükleer TıpTrakya Üniversitesi

    Dahili Tıp Bilimleri Bölümü

    DOÇ. DR. HÜSEYİN ÖZDEMİR

  2. Akut göğüs ağrısında tanıda düşük doz kontrast madde ve radyasyon kullanarak ikili ve üçlü dışlama bilgisayarlı tomografi anjiografisi kullanımı

    The use of dual and triple rule out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain

    AHMET KEREM İMREK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2022

    Radyoloji ve Nükleer TıpBolu Abant İzzet Baysal Üniversitesi

    Radyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUSTAFA HIZAL

  3. Ridge waveguide ga As / Alx ga1-x as multiple quantom well laser diodes

    Sırt dalga kılavuzu Ga As / Alx Ga1-x As çoklu kuantum kuyu lazer diyodlar

    ABDULLAH KAMURAN TÜRKOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    1994

    Fizik ve Fizik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. ATİLLA AYDINLI

  4. Gallium arsenide/aluminium gallium arsenide double heterostructure laser diodes

    Galyum arsenit/alüminyum galyum arsenit çift heterojen yapılı lazer diyotları

    CEM GEZER

    Yüksek Lisans

    İngilizce

    İngilizce

    1999

    Fizik ve Fizik MühendisliğiOrta Doğu Teknik Üniversitesi

    Fizik Ana Bilim Dalı

  5. Elektrokonvulsif tedavinin etki mekanizmasının bir hayvan modelinde en erken gen proteinlerinin gösterilmesi yoluyla araştırılması

    Başlık çevirisi yok

    S. MURAT REZAKİ

    Doktora

    Türkçe

    Türkçe

    1999

    NörolojiHacettepe Üniversitesi

    Temel Nörolojik Bilimler Bilim Dalı

    PROF. DR. TURGAY DALKARA