DA yüksek gerilim dirençsel bölücülerde ölçüm belirsizliğinin azaltılması için yeni yaklaşımlar
New approaches to reduce measurement uncertainity in HV DC resistive dividers
- Tez No: 135970
- Danışmanlar: PROF. DR. HASAN DİNÇER
- Tez Türü: Doktora
- Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
- Anahtar Kelimeler: YG dirençsel bölücüler, YG ölçüm standartları, ölçüm belirsizlikleri, PID denetim, bulanık denetim, YSA denetim, PID denetleme, Yapay sinir ağları, Yüksek gerilim, Ölçümleme, Fuzzy control, PID control, Artificial neural networks, High voltage, Measurement
- Yıl: 2003
- Dil: Türkçe
- Üniversite: Kocaeli Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
DA YÜKSEK GERİLİM DİRENÇSEL BÖLÜCÜLERDE ÖLÇÜM BELİRSİZLİĞİNİN AZALTBLMASI İÇİN YENİ YAKLAŞIMLAR Serhat YILMAZ
Özet (Çeviri)
NEW APPROACHES TO REDUCE MEASUREMENT UNCERTAINTY IN HV DC RESISTIVE DIVIDERS Serhat YILMAZ Index Terms: HV resistive dividers, HV measurement standarts, measurement uncertainties, PID control, fuzzy control, neural control In this study, design and realization of a dc voltage standart divider for highly precise measurement up to 5 kV is described. As to the effects of self heating of the resistors, chaotic distribution of this heat, leakage currents and corona effects are caused to error in measurements. Uncertainties arisen from the last two effects may be reduced by arrangements in design and construction of voltage divider systems. However, the self heating of the resistors and any temperature gradient along the resistor column is the major error source in precise measurements. New approaches are suggested and used in the system to reduce uncertainties in measurement. Thermal stabilisation of the device reduces the uncertainty in measurement on a large scale. Computer aided control of peltier cooling elements are added to keep the temperature at some certain degree and computer aided control of the circulation motor is added to approximate the temperature gradient to insignificant values. Several control methods are applied to eliminate the self-heating and heat gradient effects in the DC HV Resistive Divider. PID control, fuzzy control and neural network control programs are developed to control these effects of the system. Heat dispersion (conduction and convection) of the system is modelled to determine the number and place of the points of temperature data. Temperature sensors are placed to these suitable points for each state variables. Control outputs determine voltage of the peltier cooler and the circulation motor speed. The measurement uncertainty sourced by the heat effects are reduced to the values between 5-11 ppm. Accurate measurements of DC voltages at values above 10 V and calibrating other dividers are achieved by standart voltage dividers. The device that was realized has been the prototype of 1 00 kV DC Voltage Resistive Divider which is prepeared in TÜBİTAK-National Metrology Institute to be the DC high voltage standart of Turkey. m
Benzer Tezler
- Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi
Başlık çevirisi yok
MERİH BAYRAM
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Atherosklerotik kalp hastalıklarında risk faktörleri
Risk factors in the coronary artery disease
MURAT SUHER
- Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi
Başlık çevirisi yok
NECDET ŞÜKRÜ ALTUN