İçme sularında kurşun ve kadmiyumun atomik absorpsiyon spektrometresi ile tayini
Determination of lead and cadmium in drinking water by atomic absorption spectrometry
- Tez No: 150471
- Danışmanlar: Y.DOÇ.DR. MUSTAFA TÜZEN
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Zenginleştirme, Chromosorb 106, Kolon, Kurşun, Kadmiyum, İçme suyu, Alevli AAS, Preconcentration, Chromosorb 106, Column, Lead, Cadmium, Drinking water, FAAS
- Yıl: 2004
- Dil: Türkçe
- Üniversite: Gaziosmanpaşa Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 50
Özet
ÖZET ÎÇME SULARINDA KURŞUN VE KADMİYUMUN ATOMİK ABSORPSİYON SPEKTROMETRESİ İLE TAYİNİ KURBAN PARLAR Gaziosmanpaşa Üniversitesi Fen Bilimleri Enstitüsü Kimya Anabilim Dah Yüksek Lisans Tezi 2004, 43 sayfa Danışman : Yrd. Doç. Dr. Mustafa TÜZEN Jüri : Prof. Dr. Mustafa SOYLAK Jüri : Yrd. Doç. Dr. Mustafa TÜZEN Jüri : Yrd. Doç. Dr. Durali MENDİL Bu çalışmada, içme sularında kurşun ve kadmiyum iyonlarının tayini için katı faz ekstraksiyon prosedürü uygulandı. Kolon çalışmalarında adsorblayıcı olarak Chromosorb 106 reçinesi ve ligant olarak l-(2-piridazol) 2-naftol (PAN) kullanıldı. Çözeltinin pH'ı, eluent tipi, akış oranları, reçine miktarı ve örnek hacmini içeren analitik parametrelerin etkisi incelendi. Analitlerin geri kazanımına alkali, toprak alkali ve bazı geçiş metallerinin etkisi tartışıldı. Metodun geçerliliği standart referans maddeler kullanılarak gerçekleştirildi. Geri kazanımlar % 95 den büyük, bağıl standart sapma % 10 dan küçük bulundu.
Özet (Çeviri)
11 ABSTRACT DETERMINATION OF LEAD AND CADMIUM IN DRINKING WATER BY ATOMIC ABSORPTION SPECTROMETRY KURBAN PARLAR Gaziosmanpaşa University Graduate School of Natural and Applied Science Department of Chemistry Master Thesis 2004, 43 page Supervisor : Asst Prof. Dr. Mustafa TÜZEN Jury : Prof. Dr. Mustafa SOYLAK Jury : Asst. Prof. Dr. Mustafa TÜZEN Jury : Asst. Prof. Dr. Durali MENDİL In this study, a solid phase extraction procedure for the determination of lead and cadmium ions in drinking water samples was established. Chromosorb 106 resin and l-(2- pyridylazo) 2-naphtol (PAN) were used as adsorbent and ligand for column studies. The influences of the analytical parameters including pH of the solutions, type of eluent, flow rates, resin amount and sample volume were also investigated. The influences of alkaline, earth alkaline and some transition metals, as interferents, on the recoveries of the analytes were discussed. Validation of the method was performed by certified reference materials (recoveries greater than 95%, relative standard deviations lower than 10%).
Benzer Tezler
- Ambalaj malzemelerinden gıdaya bulaşan ve gıda güvenilirliğini tehdit eden maddelerin elektrokimyasal yöntemle tespiti
Electrochemical detection of substances which diffuse from food packaging materials and threating the food safety
YEŞİM TUĞÇE YAMAN
- Çözeltiden kurşun ve kadmiyumun uzaklaştırılması
Removal of Cd(II) and Pb(II) ions from solutions
REMZİYE GÜZEL
- Diyarbakır ili petrol üretim sahalarının çevre sularına olası etkisi ve elektrokoagülasyon yöntemi kullanılarak arıtılabilirliğinin araştırılması
The potential effects of petrol production areas of Diyarbakır province on water resources and investigation of treatability by using electrocoagulation process
HATİCE KARA
Doktora
Türkçe
2015
KimyaDicle ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. HAMDİ TEMEL
YRD. DOÇ. DR. ZEKİ TÜNAY
- Trakyanın bazı yörelerinde içilen sulardaki ağır metal ve radyoaktivite miktarlarının araştırılması
Başlık çevirisi yok
İSMİCAN SÜRMELİ
- Removal of microbial pollutants and micropollutants with reverse osmosis membranes from drinking water
Ters osmoz membranlar ile içme suyundan mikrobiyal kirleticilerin ve mikrokirleticilerin giderimi
CANSU BATIR
Yüksek Lisans
İngilizce
2019
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. İSMAİL KOYUNCU