Tamamıyla katı-hal kompozit kalsiyum seçici elektrot ve potansiyometrik davranışı
All solid-state composite calcium selective electrode and its potentionmetric performances
- Tez No: 155044
- Danışmanlar: Y.DOÇ.DR. ADEM ASAN
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: İyon-Seçici Elektrot, Katı-Hal Elektrot, Kompozit elektrot, kalsiyum iyonofor IV, ETH 5234, Ion-Selective Electrode, Solid-State Electrode, Composite Electrode, Ca ionophore IV, ETH 5234
- Yıl: 2004
- Dil: Türkçe
- Üniversite: Ondokuz Mayıs Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
11 TAMAMIYLA KATI-HAL KOMPOZİT KALSİYUM SEÇİCİ ELEKTROT VE POTANSİYOMETRİK DAVRANIŞI ÖZET Bu çalışmada kalsiyum iyonofor IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl- diglycolic daimide; N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide) aktif maddesi kullanılarak tamamıyla katı-hal kompozit kalsiyum iyon-seçici elektrot hazırlandı. Elektrodun potansiyometrik performanslan bilgisayarlı bir ölçüm sisteminde araştırıldı. Hazırlanan bütünüyle katı hal kompozit kalsiyum iyon-seçici elektrodun ana iyon çözeltisine karşı her 1 0 kat konsantrasyon değişimi için 24 mV potansiyel değişimi gösterdiği, cevap zamanının oldukça kısa (yaklaşık 10 s) ve kullanım süresinin uzun (en az 8-10 hafta) olduğu belirlendi. Hazırlanan elektrot Ixl0_1-lxl0“5 mol.L”1 konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemekteydi. Elektrodun ana iyon yamnda girişim yapan iyonlara karşı seçicilik katsayıları“ayrı çözelti metodu”ile hesaplandı ve kalsiyum iyonofor IV ile hazırlanan elektrodun özellikle Ca2+ iyonuna karşı oldukça seçici olduğu sonucuna varıldı. Ayrıca, geliştirilen elektrot, akış-enjeksiyon analiz (Fi A) sisteminde dedektör olarak kullanılarak çeşitli süt ve yoğurt örneklerindeki Ca2+ iyonunun tayini başarıyla gerçekleştirildi.
Özet (Çeviri)
Ill ALL SOLID-STATE COMPOSITE CALCIUM SELECTIVE ELECTRODE AND ITS POTENTIOMETRIC PERFORMANCES ABSTRACT In this work, a solid-state composite calcium ion-selective electrode was prepared by using calcium ionophore IV (ETH 5234, N,N-Dicyclohexyl-N',N'-dioctadecyl-diglycolic daimide;N,N-Dicyclohexyl-N'-N'-dioctadecyl-3-oxapentanediamide). The potentiometric performance characteristics of the electrode was examined with a computerized measuring system. The prepared electrode almost exhibited 24 mV potential difference per decade, short response times (approximately 10 s), long life times (at least 8-10 week), a linear response between 1.10“1-1.10”5 mol.L“1 solutions against main ion. Selective cofficients of the electrodes for againts interfering ions were calculated by ”separate solution method" and while electrodes prepared with calcium ionophore IV compound showed very high selectivity toward Ca2+ ion. Besides, prepared electrode, used as dedector in flow-injection analyse (FIA) system in some milk and yogurt samples successfully.
Benzer Tezler
- Farklı karıştırma teknikleri kullanılarak manyetik soğutma teknolojisinde kullanılan kompozit perovskite malzemelerin üretilmesi
Production of composite perovskite materials used in magnetic cooling technology using different mixing techniques
NURŞAH GÜLEÇ
Yüksek Lisans
Türkçe
2025
Fizik ve Fizik MühendisliğiMuğla Sıtkı Koçman ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. ATİLLA COŞKUN
- Amino asit biyosensörler
Improvement of the amino acid biosensors
ÖZGÜR TURNA
Yüksek Lisans
Türkçe
2006
BiyokimyaOndokuz Mayıs ÜniversitesiKimya Ana Bilim Dalı
DOÇ. DR. NİHAT TINKILIÇ
- Tamamıyla katı hal kontak sülfit seçici elektrotların hazırlanması ve test edilmesi
Başlık çevirisi yok
CEMAL YİĞİT
Yüksek Lisans
Türkçe
1996
Eğitim ve ÖğretimOndokuz Mayıs ÜniversitesiKimya Eğitimi Ana Bilim Dalı
YRD. DOÇ. DR. İBRAHİM IŞILDAK
- Crown eter bileşiklerine dayalı katı-hal potansiyometrik iyon sensörleri
Solid-state potentiometric ion sensor base on crown-ether compounds
BARIŞ KEMER
Yüksek Lisans
Türkçe
2005
KimyaKaradeniz Teknik ÜniversitesiKimya Ana Bilim Dalı
PROF.DR. MUSTAFA ÖZDEMİR
- “Yeni tip potansiyometrik üre biyosensörlerin hazırlanması ve biyolojik numunelere uygulanması”
“Preparation of new type potentiometrik urea biosensors and application to biological samples”
OSMAN ÇUBUK
Yüksek Lisans
Türkçe
2001
KimyaOndokuz Mayıs ÜniversitesiKimya Ana Bilim Dalı
YRD. DOÇ. DR. NİHAT TINKILIÇ