Özet

ÖZET Katı-hal kontak sülfit seçici elektrotlar, bir tel üzerine grafit, epoxy ve hardener (sertleştirici) karışımı kaplanarak, üzerine 4- metilpiperidinditiyokarbomat metal kompleksleri ([Hg(ll)-(4MPDC)2], Fe(lll)- (4MPDC)3 gibi) örtülerek veya Cu(ll),Ni(ll) komplekslerinin PVC membranları kaplanarak hazırlandı ve cevap karekteristikleri incelendi. İncelenen elektrotlardan sulfite karşı en güzel davranışı Hg(ll)-(4MPDC)2 kompleksi kaplı elektrot göstermektedir. Bu elektrodun katı-hal kontak yüzeyine, optimum kalınlıkta kompleks kaplandığında (cevap zamanı ve ömrüne etkisi olmaktadır), elektrot, kısa cevap zamanı ve indirgen türler için yüksek seçicilik sergilemekte, aynı zamanda kuru olarak veya destile su içinde bekletildiğinde üç hafta kullanılabilme özelliğine sahip olmaktadır. Yüksek derişimli (0.1 M) S037HS03“ veya Cu(l) gibi indirgen çözeltiler içerisinde bekletildiğinde elektrotların gösterdiği duyarlılıkta önemli ölçüde bozunma gözlendi. Elektrodun gösterdiği duyarlılık elektrot yüzeyinde bir heterojen redoks reaksiyonu ile gerçekleşmektedir, ( elektrot/çözelti yüzeyinde indirgen maddeler Hg(ll)' yi Hg(l)' e indirgemektedir ). Kontrollü şartlar altında, bu heterojen redoks reaksiyonu vasıtasıyla S037HS03”iyonları için yüksek seçicilik ve tekrarlanabilir duyarlılık elde edilmiştir. Geliştirilen katı-hal kontak elektrot 1. 1 0“1 M ile 1.1 0”6 M S037HS03“ derişim aralığında ve pH 3.0 ile 9.0 arasında doğrusal olarak duyarlılık göstermektedir. Elektrodun S037HS03”iyon çiftine karşı seçiciliği diğer sülfit seçici elektrotlarla, özellikle sıvı membran elektrotlarla, kıyaslandığında üstünlük sergilemektedir.

Özet (Çeviri)

Summary An all solid-state contact electrode sensitive for sulfite was constructed using a wire coated with a mixture of graphite, epoxy and hardener, and covered by 4-methyl piperidinedithiocarbamate mercury (II) and iron (III) complexes or PVC membranes with 4-methyl piperidinedithiocarbamate cupper (II) and nickel (II) complexes. Their preparation, and the response charecteristics were examined. With an optimum thickness of the complex at the surface of all solid-state contact, (which appears to affect the response time, slope and the life time), the electrode exhibited short response time, high selectivity for reducing species, and also was found reproducible for three weeks when kept in distilled water or dry. For the electrodes, except the elecrode prepared with Ni (II) complex, exposed to solutions containing high levels of (0.1 M) sulfite/hydrogen sulfite or reducing species e.g., Sn(ll), Cu(l), the response was significantly deterioated. The response of the electrode only to reducing species observed can be attributed to a heterogeneous redox reaction (sulfite in the sample reduces Hg(ll) to Hg(l) at the electrode/sample interface). Under controlled conditions such heterogeneous redox reaction resulted highly selective and reproducible response to reducing species,.especially to sulfite/hydrogen sulfite. The response of the all solid-state -1 -6 contact electrode was linear between 1x10 and 5x10 M sulfite/hydrogen -1 sulfite concentration, and the useful pH range from 1x10 M SO3 /HSO3 to -6 1x10 M SO3 /HSO3" was between 3.0 and 9.0. Furthermore, the selectivity of sulfite over iodide, thiocyanate, thiosulfate, and bromide was much improved compared those for a liquid membrane sulfite electrode.

Benzer Tezler

  1. Crown eter bileşiklerine dayalı katı-hal potansiyometrik iyon sensörleri

    Solid-state potentiometric ion sensor base on crown-ether compounds

    BARIŞ KEMER

    Yüksek Lisans

    Türkçe

    Türkçe

    2005

    KimyaKaradeniz Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF.DR. MUSTAFA ÖZDEMİR

  2. 'Yeni tip potansiyometrik üre biyosensörlerin hazırlanması ve biyolojik numunelere uygulanması'

    'Preparation of new type potentiometrik urea biosensors and application to biological samples'

    OSMAN ÇUBUK

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    KimyaOndokuz Mayıs Üniversitesi

    Kimya Ana Bilim Dalı

    YRD. DOÇ. DR. NİHAT TINKILIÇ

  3. Yeni aza taç-eter nötral iyonoforları ile katyon-seçici elektrodlar ve potansiyometrik performans karakteristikleri

    Cations-selective electrodes based on new aza crown-ether neutral ionophores and their potentiometric performance characteristics

    MURAT YOLCU

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    KimyaOndokuz Mayıs Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. İBRAHİM IŞILDAK

  4. Ağır metal seçici elektrotların geliştirilmesi ve hareketli ortamda sülfirid tayini

    Development of heavy metal selective electrodes and determination of sulpiride on the flowing conditions

    ÇİĞDEM YADİGAROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    KimyaOndokuz Mayıs Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. İBRAHİM IŞILDAK

  5. Bütünüyle katı-hal kontakt amonyum-seçici PVC-membran kondüktometrik elektrotlar ve performans karakteristikleri

    All solid-state contact ammonium-selective PVC-membrane conductometric electrodes and their performance characteristics

    CELAL TURAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    KimyaOndokuz Mayıs Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. İBRAHİM IŞILDAK