Geri Dön

Seramik laminalarda kırılma direncinin in vitro olarak değerlendirilmesi

Fracture resistance of ceramic veneers: An in vitro study

  1. Tez No: 164028
  2. Yazar: BURÇİN AKOĞLU
  3. Danışmanlar: PROF.DR. DENİZ GEMALMAZ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Porselen lamina restorasyonlar, dentin, kırılma dayanıklılığı, Porcelain laminate veneers, dentin, fracture resistance
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 110

Özet

1. ÖZET SERAMİK LAMİNALARDA KIRILMA DİRENCİNİN İN VİTRO OLARAK DEĞERLENDİRİLMESİ Bu çalışmanın amacı, minede sonlanan preparasyonlara uygulanan laminalar ile geniş miktarda dentin açığa çıkmış olan preparasyonlar üzerine uygulanan laminaların kırılma dirençlerinin değerlendirilmesidir. Bu çalışmada 75 adet homojen boyutlara sahip olan, çekilmiş üst santral kesici diş kullanıldı. Dişlerde çürük ve restorasyon olmamasına dikkat edildi ve 15 dişten oluşan 5 gruba ayrıldı. 1) 2 mm insizal indirgeme, minede hazırlanan preparasyon, 2) 4 mm insizal indirgeme, minede hazırlanan preparasyon, 3) 2 mm insizal indirgeme, dentinde hazırlanan preparasyon, 4) 4 mm insizal indirgeme, dentinde hazırlanan preparasyon, 5) Kontrol amacı ile prepare edilmemiş dişler. Preparasyonda insizal kenarda düz bitim hattı oluşturulurken, iç açılan yuvarlatılmış, mine sement sınırının 1 mm üzerinde sonlanan preparasyonlar yapıldı. IPS Empress (Ivoclar, Schann, Liechtenstein) tam seramik lamina restorasyonlar hazırlandı ve Syntac Classic adeziv sistem ve Variolink II (Ivoclar, Schann, Liechtenstein) rezin simanla simante edildi. Dişlere 30 saniyelik süre ile 5 ± 1 C° - 55 ± 1 C° arasında 3500 termal siklus uygulandı. Universal test cihazı kullanılarak, palatinal yüzeyden insizal kenarın 2,5 mm altından 90°lik açı ile 0,5 mm/dak hızda kırma testi gerçekleştirildi. Deney grupları için elde edilen ortalama kırılma değerleri: Grup 1: 262,36 N, Grup 2: 189, 0733 N, Grup 3: 239, 52 N, Grup 4: 161,90 N, Grup 5: 277,2 N. Sonuç olarak prepare edilmemiş kontrol dişleri ile 2 mm insizal indirgeme yapılarak mine ve dentinde hazırlanan gruplar arasındaki fark istatistiksel olarak anlamlı bulunmamıştır. İki mm insizal indirgeme yapılarak mine yüzeyinde hazırlanan preparasyonlar ile 4 mm insizal indirgeme yapılarak mine ve dentinde hazırlanan preparasyonlar arasında istatistiksel olarak anlamlı farklılık gözlendiği tespit edilmiştir. 2 mm insizal indirgeme yapılarak dentin yüzeyinde hazırlanan preparasyonlar ile 4 mm insizal indirgeme yapılarak dentinde hazırlanan preparasyonlar arasında istatistiksel olarak anlamlı farklılık gözlendiği tespit edilmiştir. İnsizal indirgeme miktarı arttıkça kırılma dayanıklılığının azaldığı gözlenmiştir.

Özet (Çeviri)

2. SUMMARY FRACTURE RESISTANCE OF CERAMIC VENEERS: AN IN VITRO STUDY The purpose of this in vitro study was to examine the fracture load of ceramic veneers with preparations at enamel or at dentin. For this study 75 extracted intact human maxillary central incisors with homogeneous dimensions were selected. Each tooth was free of dental caries or restorations. Teeth were divided in 5 groups of 15 specimens: 1)2 mm incisal reduction, preparation entirely in enamel, 2)4 mm incisal reduction, preparation entirely in enamel, 3) 2 mm incisal reduction, preparation entirely in dentin, 4 ) 4 mm incisal reduction, preparation entirely in dentin, 5) Unrestored, intact teeth as control. All the preparations had a butt joint incisal finish line, rounded internal line angles and the cervical finish lines were 1 mm above the cementoenamel junction. All veneers were fabricated with IPS Empress staining technique(Ivoclar, Schann, Liechtenstein) and cemented with Syntac Classic Adhesive system and Variolink II (Ivoclar, Schann, Liechtenstein) composite resin cement. The teeth were thermocycled between 5 ± 1°C and 55± 1°C for 3500 cycles with a dwell time of 30 seconds. The fracture loads were determined using a universal testing machine. The load was applied at a 90° angle to the lingual surface of the test tooth. The load was consistently applied at 2.5 mm from the incisal edge. The plunger was attached to the load cell, and crosshead speed was 0.5 mm/min. The mean fracture loads (N) are: Group 1: 262,36 N, Group 2: 189, 0733 N, Group 3: 239, 52 N, Group 4: 161,90 N, Group 5: 277,2 N. There wasn't any significant difference between fracture strengths of the control group and the groups with incisal reduction. There was significant difference between Group 1 and Group 2 - Group 4. There was significant difference between Group 3 and Group 4. The fracture strength decreased as the amount of incisal reduction increased.

Benzer Tezler

  1. Seramik ve rezin içerikli farklı CAD/CAM laminate veneer restorasyonlarda bağlanma direncinin değerlendirilmesi

    Evaluation of bond strength in different CAD/CAM laminate veneer restorations with ceramic and resin content

    METİN BAKIR

    Doktora

    İngilizce

    İngilizce

    2018

    Diş HekimliğiDicle Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ŞEYHMUS BAKIR

    DOÇ. DR. EMRULLAH BAHŞİ

  2. Fracture load and mode of failure of ceramic laminate veneers with different cementation methods

    Farklı simantasyon metodu kullanılan seramik laminalarda kırılma dayanıklılığı ve kırık paterni dayanıklılığı

    HEND ELKAWASH

    Yüksek Lisans

    İngilizce

    İngilizce

    2005

    Diş HekimliğiMarmara Üniversitesi

    Protez Ana Bilim Dalı

    PROF. DR. DENİZ GEMALMAZ

  3. Development and characterization of light-weight armor materials

    Kompozit hafif zırh malzemelerin geliştirilmesi ve karakterizasyonu

    EROL ÜNALER

    Yüksek Lisans

    İngilizce

    İngilizce

    2005

    Mühendislik Bilimleriİzmir Yüksek Teknoloji Enstitüsü

    Malzeme Bilimi ve Mühendisliği Ana Bilim Dalı

    DOÇ.DR. METİN TANOĞLU

    DOÇ.DR. MUSTAFA GÜDEN

  4. In vitro comparison of the shear bond strength for glass ceramic laminate veneer material by the using of two different adhesive systems

    İki farklı yapıştırma sistemi kullanılarak cam seramik laminaların dişlere bağlanma kuvvetlerinin in vitro değerlendirilmesi

    ASMA F S ELBADRI

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Diş HekimliğiYeditepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ENDER KAZAZOĞLU

  5. Numerical modeling of delamination failure in ceramic matrix composite

    Seramik matrisli kompozitlerde delaminasyon hasarının sayısal modellenmesi

    LEVENT BOZKURT

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. EKREM TÜFEKCİ