Bölümlü protez yapımında kullanılan materyallerden polimetilmetakrilatın dokularda oluşturduğu reaksiyonlara elektromanyetik alanın etkisi

Effects of electromagnetic field to subcution tissue reactions caused by polymethylmetacrylate used in manifacturing Partial denture

  1. Tez No: 164402
  2. Yazar: EMRE ZAİM
  3. Danışmanlar: PROF.DR. YÜKSEL TÜRKÖZ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Polimetilmetakrilat, darbeli elektromanyetik alan, doku reaksiyonu, Polymethylmetacrylate, pulsed electromagnetic field, tissue reaction
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 102

Özet

84 ÖZET Bölümlü protez yapımında kullanılan materyallerden polimetilmetakrilatın deri altı bağ dokusunda oluşturduğu reaksiyonlara elektromanyetik alanın etkisi Çalışmamızda, diş hekimliğinde hareketli bölümlü ve tam protez kaide yapımında rutin olarak kullanılan polimetilmetakrilatın (PMMA) oluşturduğu doku reaksiyonları üzerine, yapay olarak oluşturulan darbeli elektromanyetik alanın (PEMF) olumlu ve / veya olumsuz etkilerinin araştırılması amaçlanmıştır. Çalışmamızda, 120 adet İngiliz cinsi dişi 3 aylık beyaz fareler kullanılmıştır. Polimetilmetakrilat esaslı Paladent" 20 ticari isimli ısı ile polimerize olan akrilik rezin kullanılarak 2mm3 boyutlarında 60 adet örnek hazırlanmıştır. Fareler deney süresi boyunca özel olarak yapılmış, PEMF üretecinde bulunan bobinler arası mesafeye uygun, 14 x 29 x 20 cm boyutlarındaki 6 adet pleksiglas kafeste banndırılmıştır. Çalışmamız için seçilen fareler her birinde 30 dişi fare olmak üzere 4 ayrı gruba ayrılmıştır. I. grubu oluşturan farelerin sırt bölgelerine insizyon yapılmış, implantasyon yapılmadan kapatılmıştır ve PEMF'ye maruz bırakılmamıştır. II. grubutaki farelere insizyon yapılmış, implantasyon yapılmadan kapatılmış ve PEMF'ye maruz bırakılmıştır. III. Grubu oluşturan farelerin deri altlarına PMMA implante edilmiş ve PEMF'ye maruz bırakılmıştır. IV. Gruptaki farelere ise PMMA implante edilmiş ve PEMF'ye maruz bırakılmamıştır. Deney periyodu olarak 15, 30 ve 90 günlük 3 ayrı süre seçilmiştir. Darbeli elektromanyetik alana maruz bırakılan gruplara 60 Hz 5 mT'lık darbeli elektromanyetik alan günde 12 saat süreyle uygulanmıştır. İmplantlı ve implantsız farelerde deney periyotlarının sonlarında elde edilen doku örnekleri histopatolojik olarak değerlendirilmiştir. Elde edilen sonuçlar Kruskal - Wallis Varyans analizi ve Çoklu Karşılaştırma Testi ile istatistiksel olarak değerlendirilmiştir. Çalışmamızın sonuçlan 90 günlük PEMF uygulamalarının antiödematöz aktivite oluşturduğunu göstermiştir. Çalışmamızda 15 günlük 60 Hz 5 mT'lık PEMF uygulamaları bağ dokusu oluşumunu hızlandırdığı ortaya konmuştur. 15 günlük PEMF uygulamaları nötrofil infiltrasyonunu hızlandırmıştır. Çalışmamız 15 günlük ve daha uzun süreli PEMF uygulamalarının lenfosit infiltrasyonunu baskıladığını göstermiştir. PEMF'nin 15 gün ve daha uzun süre uygulanması makrofaj infiltrasyonunu baskıladığı ve 15 günlük ve daha uzun süreli 60 Hz 5 mT'lık PEMF uygulamaların da ise mast hücresi infiltrasyonunun baskılandığı gösterilmiştir.

Özet (Çeviri)

85 SUMMARY Effects of Electromagnetic Field to Suhcutan Tissue Reactions Caused by Polymethylmetacrylate Used in Manifacturing Partial Denture The aim of the present study was to determine the negative and positive effects of pulsed electromagnetic field applications against tissue reactions which are caused by polymethylmetacrylate. A total number of 120 mices were divided into groups equally. Polymethylmetacrylate samples were made from Paladent 20® commertially named polymethylmetacrylate in 2mm3 size. In the first group, only an incision were made on to the back of the mices and pulsed electromagnetic field was not applied. An incision was made and pulsed electromagnetic field was applied to the mices in the second group. In the third group, polymethylmetacrylate was implanted into the back of the mices and pulsed electromagnetic field was also applied. Only polymethylmetacrylate was implanted in to the mices which are in the fourth group, but pulsed electromagnetic field was not applied. Three different experiment periods chosen as 15, 30 and 90 days. A pulsed electromagnetic field of 60 Hz frequency and 5 mT intensity was applied for 12 hours in a day during the experiment periods. The tissue samples obtained at the end of the experiment periods were evaluated histopathologically. At the end the results were evaluated statistically using Kruskal - Wallis Varying Analysis and Multiple Comparisons Test. The results of the study were revealed that; application of 60 Hz 5 mT pulsed electromagnetic field for 90 days has anti edematous activity, application pulsed electromagnetic field for 15 days has supressed the number of lymphocytes, mastocytes, macrophages and increases granulation tissue formation and neutrophyl leucocyte emigration. It was concluded that allergic reaction which can be caused by polymethylmetacrylate can be eliminated by using extremely low frequency pulsed electromagnetic field.

Benzer Tezler

  1. Kimyasal protez temizleyicilerinin farklı yüzey işlemi uygulanmış kobalt-krom metal alaşımı ile akrilik kaide rezini arasındaki bağlantı üzerine etkisi

    The effect of chemical denture cleaners on the shear bond strength between cobalt-chrome metal alloy applied in different surface treatment and acrylic base resins

    ÜMRAN YILMAZ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. GÜLAY KANSU

  2. Tam ve metal destekli porselenlerde marjin seramiğinin yapımında kullanılan iki farklı yöntemin seramik homojenitesine etkisinin incelenmesi

    The examination of the effect of two different methods which are used in the construction of margin ceramics in the all and metal reinforced porcelain on the ceramic homogeneity

    UMUT GÜLER

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiHacettepe Üniversitesi

    Protez Ana Bilim Dalı

    PROF. ŞENAY CANAY

  3. İmplant destekli sabit protez yapımında direkt dijital ölçü için kullanılan farklı tarama postlarının hassasiyetinin değerlendirilmesi: metodolojik klinik çalışma

    Precision of different scan-bodies used for direct digital impression in fabrication of implant supported fixed prosthesis: A methodological clinical study

    FATMANUR DEMİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiHacettepe Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. KIVANÇ AKÇA

  4. Çeşitli organik tükürük komponentlerinin dişhekimliğinde kullanılan farklı döküm alaşımları ve amalgam'ın korozyonu üzerine etkisi

    The effect of different organic compoments of saliva on the corrosion behavior of various dental casting alloys and amalgam

    HAKAN BİLHAN

    Doktora

    Türkçe

    Türkçe

    2003

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN BİLGİN

  5. Metal destekli sabit bölümlü protez uygulanan bireylerde olası genotoksik hasarın incelenmesi

    Evaluation of possible genotoxic damage in patients used fixed partial prostheses

    GÜLCE ALP

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. YAVUZ BURGAZ