Geri Dön

Biyomekanik deneylerde kullanılmak üzere in vitro osteoporotik vertebra modeli oluşturulması

Development of osteoporotic vertebra model for in-vitro experimental applications in biomechanics

  1. Tez No: 164538
  2. Yazar: ATİLLA AKBAY
  3. Danışmanlar: PROF. DR. NEJAT AKALAN
  4. Tez Türü: Doktora
  5. Konular: Nöroşirürji, Neurosurgery
  6. Anahtar Kelimeler: Osteoportik vertebra modeli, dekalsifikasyon, pull-out, pedikül vidası, DEXA, Osteoporotic vertebrae model, decalcification, pull-out, pedicle screw, DEXA
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Nöroşirürji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Akbay A. Biyomekanik deneylerde kullanılmak invitro osteoporotik vertebra modeli oluşturulması. Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Nöroendokrinşirürji Programı Doktora Tezi, Ankara, 2005. Günümüzde osteoporoz gelişmiş ülkeler başta olmak üzere yaygın ve evrensel bir problemdir. Hastalık genel olarak sessiz seyredip vertebra ve kalça kırıklarıyla bulgu vermektedir. Vertebra kırıklarına osteoporoz hastalarının yaklaşık yarısında rastlanmakta ve bu kırıkların bir kısmı cerrahi tedaviye ihtiyaç göstermektedir. Ancak osteoporotik vertebrada fiksasyonun kendine özgün ciddi sorunları bulunmaktadır. Günümüzde bu sorunları aşmak üzere yoğun çalışmalar yürütülmekte, pekçok yeni fiksasyon sistemleri ve yeni cerrahi yöntemler tanımlanmaktadır. Ancak yeni yapılan araç ve fiksasyon cihazlarının, özellikle pedikül vidalarının osteoporotik deney hayvanları üzerindeki araştırmaları araştırıcıları zorlamaktadır. Çünkü osteoporotik vertebra elde etme süreci uzun zaman alır ve deneyin maliyeti yüksektir. Bu çalışmanın amacı, omurgada yapılacak biyomekanik çalışmalara uygun, tekrarlanabilir, hızlı ve ucuz bir yolla osteoporotik vertebra karakteristikleri gösteren vertebralar elde etmektir. Toplam 24 vertebra deney ve kontrol grubu olarak ikiye ayrıldı, deney grubundaki vertebralara yeni geliştirilen bir yöntemle asit demineralizasyon işlemi uygulandı. Vertebraların işlem öncesi 1.43±0,08 gr/cm olan kemik mineral yoğunlukları işlem sonrasında 1.12±0,07 gr/cm ye düştü. Paired t-testi ile iki kemik yoğunluğu arasındaki farkın anlamlı olduğu saptandı (p<0,001).Daha sonra normal vertebralar ile osteoporotik vertebralara pedikül vidaları yerleştirilip çekme direnci saptandı. Normal vertebraların çekme dayanımı 1602,5±288,7 N iken, osteoporotik hale getirilen vertebraların ortalama dayanımı 668,125±170,8 N'a düştü. Non-paired çift yönlü t-testi ile çekme dayanımları arasındaki farkın anlamlı olduğu görüldü (p<0,001).Yeni geliştirilen asit dekalsifikasyon yöntemi ile büyük deney hayvanlarının vertebralarından, invitro biyomekanik testler yapmaya uygun osteopenik-osteoporotik vertebralar elde edilebilmiştir.

Özet (Çeviri)

VI ABSTRACT Akbay A. Development of osteoporotic vertebra model for in-vitro experimental applications in biomechanics. Hacettepe University Institute of Health Sciences, neuroendocrine Surgery PhD thesis, Ankara, 2005. Tests of newly developed spinal instrumentation material to an osteoporotic vertebra model are generally neglected because of high costs of osteoporotic vertebrae. The production of osteoporotic vertebra in animals is expensive and time consuming. The objective of this study is to produce an osteoporotic vertebra in an animal model in-vitro for experimental applications in biomechanics. This study was performed on 24 fresh lumbar vertebrae from 4 calf lumbar spine. Vertebrae were divided into 2 groups (experimental and control groups). Bone mineral density was measured to see pre- process BMD and BMC by DEXA in antero-posterior direction by placing the specimens at sagittal plane. A hole was opened in the pedicles of each vertebra. These holes were extended to 4 cm with a blunt-tip probe. In experimental group, each vertebra was put into a beher-glass filled with a hydrochloric acid decalcifier solution. The decalcifier solution in 50 cc volumes was introduced through the holes with an infusion pump. After keeping and irrigating, the vertebrae were washed with saline. These procedures were made with saline at control group. The vertebrae were then subjected to DEXA as described above to measure post process BMD. After the BMD measurement process, both pedicles of each vertebra were tapped and pedicle screws were introduced. Following, each vertebra was secured into material testing machine. Pullout test was done at the rate of 5mm/min. We used paired t-test for BMD data. The mean BMD measurement for pre-process was found as 1,43 ± 0.08 9 9 g/cm and for post process, was found 1,12 ± 0.07 g/cm. The Paired t-test showed the difference to be statistically significant (p<0,001) The mean peak pullout load was found 668,125 ± 170,8 N in post process group and 1602,5 ± 288,7 N in control group. The t-test showed the difference to be statistically significant (p<0,001). The statistical analysis showed that BMD measurement values and pedicle screw pullout forces could be reduced by this method. This method could be utilized for produce an osteoporotic vertebrae in in-vitro for experimental applications in biomechanics.

Benzer Tezler

  1. Osteoporotik vakalarda kullanılan kanüllü pedikül vidaların invitro mekanik özellikleri açısından tasarım değişkenlerinin incelenmesi

    In vitro study of mechanical properties of cannulated pedicle screws in terms of design variables at patients with osteoporosis

    MEHMET FATİH TORAMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Makine MühendisliğiTobb Ekonomi ve Teknoloji Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. TEYFİK DEMİR

  2. Targeting circulating breast cancer stem cells via mTOR and WNT inhibitors after bone metastasis

    Sirküle meme kanseri kök hücrelerinin kemik metastazı sonrası mTOR ve WNT inhibitörleri ile hedeflenmesi̇

    ÖZLEM ALTUNDAĞ ERDOĞAN

    Doktora

    İngilizce

    İngilizce

    2025

    BiyokimyaHacettepe Üniversitesi

    Kök Hücre Ana Bilim Dalı

    PROF. DR. BETÜL ÇELEBİ SALTIK

  3. Sualtı araçlarından yayılan titreşim kaynaklı gürültünün sonlu eleman-sınır eleman metoduyla analizi

    Vibro-acoustic analysis of underwater structures using finite and boundary element methods

    BURAK ÜSTÜNDAĞ

    Doktora

    Türkçe

    Türkçe

    2024

    Gemi Mühendisliğiİstanbul Teknik Üniversitesi

    Gemi İnşaatı ve Gemi Makineleri Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET ERGİN

    PROF. DR. BAHADIR UĞURLU

  4. Characteristics of cold sprayed titanium based coatings

    Soğuk gaz dinamik püskürtme yöntemiyle üretilmiş titanyum esaslı kaplamaların karakteristiği

    AHMET HİLMİ PAKSOY

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Mühendislik Bilimleriİstanbul Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    PROF. DR. MURAT BAYDOĞAN

    DOÇ. DR. ERDEM ATAR

  5. In vivo indenter experiments on soft biological tissues for identification of material models and corresponding parameters

    Mekanik malzeme modeli ve ilgili parametrelerin kestirilmesi için yumuşak biyolojik dokular üstünde yapılan yerinde indentör deneyleri

    ALİ TOLGA PETEKKAYA

    Yüksek Lisans

    İngilizce

    İngilizce

    2008

    Makine MühendisliğiOrta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. ERGİN TÖNÜK