Geri Dön

Escherichia coli'nin sonikasyonla inaktivasyonuna farklı amplitüd, pH ve sıcaklığın etkisi

Influence of different amplitudes, pH and temperatures for inactivation of E. coli by sonication

  1. Tez No: 178996
  2. Yazar: SENEM ÇİL
  3. Danışmanlar: YRD. DOÇ. DR. BUKET KUNDUHOĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mikrobiyoloji, Biyoloji, Microbiology, Biology
  6. Anahtar Kelimeler: Predictive modelleme, E. coli, Ultrasound, İnaktivasyon, D değeri, Predictive modeling, E. coli, Ultrasound, Inactivation, D value
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Eskişehir Osmangazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyoloji Ana Bilim Dalı
  12. Bilim Dalı: Genel Biyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu araştırmanın amacı güç ultrasoundunun, sitrat tamponundaki Escherichia coli ATCC 25922 üzerindeki inaktive edici etkisini değerlendirmektir. Ayrıca, E coli inaktivasyonu üzerine pH ve akustik enerji şiddetinin (AED) etkisi de araştırılmıştır. Ölüm oranları 3 sıcaklık (20°C, 30°C ve 40°C), 2 pH (4.0 ve 7.0) ve 2 AED düzeyi (3.0 ve 7.3 W/ml) kombinasyonları için hesaplanmıstır. E coli hücrelerinin ultrasonik uygulamalardaki inaktivasyonu 1. dereceden reaksiyon kinetiğine uyum göstermiştir. İnaktivasyon sabitleri Log/dk yada 1/D olarak hesaplanmıstır. Sonikasyon yapılmayan uygulamalardaki E coli inaktivasyonu önemsiz olmuştur. Sonikasyon yapılan uygulamalarda ise, sonikasyonun genliği (AED) arttıkça inaktivasyon düzeyleri artmıstır. En yüksek inaktivasyon düzeyi 7.3 W/ml AED düzeyinde, 40°C de ve pH 7' de yapılan uygulamada 5.78 Log/dk olarak belirlenmiştir. Sonuçlarımıza göre kullandıgımız laboratuvar tipi ultrasound cihazıyla, 10 ml' lik süspansiyondaki E coli hücrelerinin 5 log birim kadar indirgenmesi için gerekli olan uygulama süresi 52 saniyedir.

Özet (Çeviri)

The objective of this research was to evaluate the efficacy of power ultrasound (20 kHz, 750 W) on inactivation of Escherichia coli ATCC 25922 in citrate buffer at sub-lethal temperatures. The effects of pH and Acoustic Energy Densities (AED) on the inactivation of E. coli were also investigated. Death rates were measured for a combination of three temperatures (20°C, 30°C and 40°C), two pH levels (4.0 and 7.0) and two Acoustic Energy Densities, AED (3.0 and 7.3 W/ml). Inactivation of the E. coli cells by ultrasonic irradiation was showed first-order behavior. The inactivation rate constants calculated as log/min or 1/D. Inactivation of E. coli for non-sonic treatments was negligible. In the sonic treatments, inactivation rates were increased with increasing amplitude of the sonication (AED). The maximum inactivation rate was determined as 5.78 log/min at 7.3 W/ml AED level at 40 °C for pH 7.0. According to result, treatment duration for 5 log reduction of E. coli was 52 s for 10 ml suspension with our laboratory type equipment.

Benzer Tezler

  1. Ultrasonikasyonun vişne suyunun bazı kimyasal ve mikrobiyolojik özelliklerine etkisinin yüzey cevap yöntemi ile belirlenmesi

    Determination of effectiveness of ultrasonication on some chemical and microbiological properties of sourcherry juice by response surface methodology

    TUĞBA TÜRKEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Abant İzzet Baysal Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Kadın genital bölgesi vajen ve serviks mikrobiyal flora dağılımı ve enfeksiyon etkeni patojen mikroorganizmaların tanımı

    The Distrubition of microbial flora of vagina nd cervix in women genital tract and description of pathooen microorganism which are infection agent

    NİHAL YÜCEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...

  3. Köy-tür tavuk mezbahasında kesilen broiler piliçlerde karaciğerde gözlenen morfolojik değişiklikler

    Başlık çevirisi yok

    HATİCE ERÖKSÜZ (BOSTANCIOĞLU)

    Doktora

    Türkçe

    Türkçe

    1993

    Fırat Üniversitesi

    Veterinerlik Patolojisi Ana Bilim Dalı

    Yükleniyor...

  4. Bölgemizdeki infeksiyöz ishalli olgulardan izole edilen patojen e. coli tipleri ve bu mikroorganizmaların antibiyotik duyarlılıklarının incelenmesi

    Başlık çevirisi yok

    SÜLEYMAN AYGÜN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1988

    Ondokuz Mayıs Üniversitesi

    Klinik Mikrobiyoloji ve Enfeksiyon Hastalıkları Ana Bilim Dalı

    Yükleniyor...