Kompozit rezinin yüzey sertlik değerleri üzerine farklı ışık cihazlarının etkisi
Effect of different light curing units on the surface hardness of a composite resin
- Tez No: 193790
- Danışmanlar: PROF.DR. GÜRKAN GÜR
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Kompozit rezin, polimerizasyon, ışık polimerizasyon cihazı, yüzey sertliği, kavite derinliği, Composite resin, polymerization, light curing unit, surfacehardness, cavity depth
- Yıl: 2007
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
66ÖZETKOMPOZİT REZİNİN YÜZEY SERTLİK DEĞERLERİ ÜZERİNE FARKLIIŞIK CİHAZLARININ ETKİSİBu çalışmanın amacı; halojen standart ışık cihazı, halojen turbo uçlu ışık cihazı, LEDışık cihazı ve Plazma Ark ışık cihazı olmak üzere farklı ışık cihazlarıyla polimerizeedilen farklı kalınlıktaki nanohibrit kompozit rezinin yüzey sertliğinideğerlendirmektir.Bu amaçla 2 mm, 3 mm ve 4mm kalınlıktaki pleksiglass kalıplar üzerinde 5 mmçapında toplam 210 adet yuva hazırlandı ve yuvalara kompozit rezin uygulandı. Üstyüzeyleri önce matriks bant sonra 1 mm kalınlığında bir mikroskop camı ilekapatılarak fazla materyalin uzaklaşması için basınç uygulandı. Bu şekildehazırlanan örneklerden 2 mm kalınlıkta olanlardan 10 tanesine halojen standart ışıkcihazı ile 40 s, 10 tanesine halojen turbo uç ile 10 s, 10 tanesine LED ışık cihazı ile10 s, 10 tanesine LED ışık cihazı ile 20 s, 10 tanesine PAC ışık cihazı ile 3 s, 10tanesine PAC ışık cihazı ile 6 s ve 10 tanesine de PAC ışık cihazı ile 10 s süreyle ışıkuygulandı. Aynı işlem 3 mm ve 4 mm kalınlıktaki örnekler için tekrarlandı. Tümörnekler için ışık cihazının ucu cam tabakaya temas edecek şekilde tutularakstandardizasyon sağlandı. Işıkla polimerizasyonu takiben matriks bantlar çıkarıldı vediskler yardımıyla bitirme ve cila işlemleri uygulandı. Örnekler kalınlıklarına göre 3gruba ayrıldı, gruplarda kendi içinde ışık cihazı ve polimerizasyon sürelerine göre 10adet örnek olacak şekilde 7 gruba ayrıldı. Bütün deney gruplarındaki örnekler ışığıgeçirmeyecek şekilde özellikle kahverengi cam şişelere yerleştirilerek 37ºC'deetüvde 1 hafta kuru hava ortamında bekletildi. Bu süre sonunda örnekler distile su ileyıkanıp kurutma kağıtları ile kurutuldu. Daha sonra Vickers yüzey sertlik ölçümcihazı ile her bir örneğin üst ve alt yüzeyinin üç değişik noktasından yüzey sertlikölçümleri yapıldı.Her bir örneğin Vickers sertlik değerleri kaydedilerek ortalamaları hesaplandı.Sonuçlar Kruskal Wallis Tek Yönlü Anova ve Mann-Whitney karşılaştırma yöntemikullanılarak istatistiksel olarak değerlendirildi (p<0,01).İstatistiksel analiz sonuçlarına göre gruplar arasında anlamlı farklılıklar bulundu(p<0,01). Kompozit rezinlerin yüzey sertliğinin kullanılan ışık cihazı ve uygulamasürelerine göre değiştiği saptandı.Halojen, LED ve PAC ışık cihazlarının kompozit rezinlerin yüzey sertliği üzerineetkisi, uygulanma sürelerine ve kavite derinliklerine göre değişiklik göstermektedir.Üst yüzeyde sertlik değerlerinde en yüksek değerler LEd 20 s'de gözlenmiştir. Altyüzey sertlik değerlerinde ise en düşük sertlik değeri PAC 3 s ile polimerize edilen 4mm'lik kompozit örnekte bulunmuştur. 4 mm'lik kompozit kalınlığında halojen 40 s67kabul edilebilir en düşük sertlik değerlerini verirken diğer polimerizasyonuygulamaları yetersiz değerleri vermiştir.PAC ışık cihazları tavsiye edilen kısa uygulama sürelerinde polimerizasyon derinliğiaçısından yeterli bulunmamıştır.Bütün polmerizasyon uygulamalarında kavite derinliğinin artması sonucunda altyüzeydeki sertlik değerlerinin azaldığı bulunmuştur.
Özet (Çeviri)
68SUMMARYEffect of Different Light Curing Units on the Surface Hardness of aComposite ResinThe aim of this study was to evaluate the effect of various light curing unitssuch as; Quartz Tungsten Halogen light curing unit with standard tip and turbotip, LED curing unit and Plasma Arc curing unit on surface hardness of ananohybrid composite.210 Standard holes, each 2 mm, 3 mm and 4mm in thickness and 5 mm indiameter were prepared on plexiglass molds and were fılled with a nanohybridcomposite resin. Top surface of each speciment was covered with a matrix strip,1 mm thick glass slide was placed over the matrix strip and pressure wasapplied to extrude excess material. 10 specimens in 2 mm thickness werepolymerized with halogen curing unit with standard tip for 40 seconds. 10specimens were cured with halogen curing unit with turbo tip for 10 seconds. 10specimens were cured with LED curing light for 10 sec. whereas 10 specimenswere cured with LED curing light for 20 seconds. 10 specimens were cured withPAC curing unit for 3 sec, 10 specimens were cured with PAC curing unit for 6sec and 10 specimens were cured with PAC curing unit for 10 seconds. Sameprocedure was applied to the specimens in 3 mm and 4 mm thickness. The lightsource tip of the curing units were positioned directly over the glass slide forstandardization. After light curing, the glass cover and matrix strips wereremoved and the top surface of each specimen was finished and polished withdisks. The specimens were divided into 3 groups according to thickness, theneach group was assigned into 7 groups each containing 10 specimens accordingto the different curing units and polymerization periods. All specimens wereplaced into dark colored glass containers and were stored at 37ºC for one week.After the storing period, composite specimens were washed with distilled waterand blotted dry. Surface hardness measurements were made by using Vickerssurface hardness measuring device from three different points on the top andbottom surfaces of each specimen.The Vickers hardness of the specimens were recorded and the average valueswere calculated. The results obtained were subjected to statistical analysis usingKruskal Wallis one-way ANOVA and Mann Whitney Multiple Range test at asignificance level of p<0,01.According to results of statistical analysis, significant differences were foundamong groups (p<0,01). Surface hardness of composite resins varied accordingto curing units and polymerization periods.Effect of halogen, LED and PAC curing units on surface hardness of compositesvaried according to application periods and cavity depth.Among the top surface hardness values, the highest value was obtained withLED 20 s. Among the bottom surface hardness values the lowest hardness was69obtained with PAC 3 s in 4 mm depth. In 4 mm depth halogen 40 s gaveacceptable minimum hardness value, other polymerization applications resultedin inadequate hardness values.PAC curing unit was found inadequate within recommended polymerizationperiods.In all polymerization applications, bottom surface hardness values decreased ascavity depth increased.
Benzer Tezler
- Farklı ışık cihazlarıyla polimerize edilen iki kompozit rezinin yüzey sertlikleri üzerine çeşitli likitlerin etkisi
The effect of various liquids on the surface hardness of two composites polymerized with different light curing units
DENİZ DELİKTAŞ
Doktora
Türkçe
2006
Diş HekimliğiAnkara ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
PROF.DR. NURAN ULUSOY
- İki farklı LED ışık cihazının nanohibrid kompozit rezinin mikromekanik özellikleri üzerine etkisi
Effect of two different LED light curing units on the micromechanical properties of a nanohybrid composite resin
ZEYNEP BİLGE KÜTÜK
Doktora
Türkçe
2015
Diş HekimliğiHacettepe ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
PROF. DR. SEVİL GÜRGAN
- Farklı ağartma yöntemleri uygulanmış iki kompozit rezinin; mikrosertlik, renk değişimi, mikrosızıntı ve bağlanma kuvvetleri yönünden değerlendirilmesi
Başlık çevirisi yok
FUNDA ERSÖZ
Doktora
Türkçe
1998
Diş HekimliğiAnkara ÜniversitesiDiş Hastalıkları ve Tedavisi Ana Bilim Dalı
DOÇ. DR. OSMAN GÖKAY
- Farklı fotobaşlatıcılar içeren kompozit rezinlerin mekanik özelliklerinin değerlendirilmesi
Evaluation of mechanical properties of composite resins with different photoinitiators
RAGHIB A.R. SURADI
Doktora
Türkçe
2019
Diş HekimliğiGazi ÜniversitesiRestoratif Diş Tedavisi Ana Bilim Dalı
PROF. DR. HACER DENİZ ARISU
- Işık şiddetinin mikrofil ve hibrit kompozitlerin polimerizasyonu ve fiziksel özellikleri üzerine etkisinin araştırılması
Başlık çevirisi yok
SALİHA ŞEYMA KABAN