Geri Dön

Çeşitli biyolojik ve çevre örneklerindeki kobalt, bakır, nikel ve demir gibi eser elementlerin yüksek performanslı sıvı kromatografisi ile tayini

The determination of trace elements as cobalt, copper, nickel and iron in different biologycal and environmental samples with high performance liquid chromatograpy

  1. Tez No: 200193
  2. Yazar: HARUN ÇİFTÇİ
  3. Danışmanlar: DOÇ.DR. ALİ ÖLÇÜCÜ
  4. Tez Türü: Doktora
  5. Konular: Biyokimya, Kimya, Biochemistry, Chemistry
  6. Anahtar Kelimeler: HPLC, Eser Element, 4-(2-piridilazo) resorsinol, UV-Visible, Demir, Nikel, Kobalt, PAR, Resorsinol, HPLC, Trace Element, 4-(2-pyridylazo)-resorcinol, UV-Visible, Iron, Nickel, Cobalt, PAR, Resorcinol
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Yüksek performanslı sıvı kromatografisi (HPLC) ile Fe(III), Ni(II) ve Co(III) gibigeçiş metal iyonlarının, 4-(2-piridilazo) resorsinol (PAR) ligandı ile komplekslerihazırlanılarak çeşitli bitkilerdeki analizleri gerçekleştirildi..Fe(III), Ni(II), Co(III) ve Cu(II) iyonlarının PAR ligandı ile kompleks hazırlamaincelendi. Bahsedilen iyonların PAR ile oluşturdukları komplekslerin şartlarıstokiyometrileri mol oranı ve job yöntemi kullanılarak Fe(III), Ni(II), Co(III) iyonları için(Metal/Ligand) 1:2, Cu(II) iyonu için 1:1 olduğu bulundu. Kompleks oluşum sürelerimetanol-su ortamında Fe(III), Co(III), Ni(II) ve Cu(II) kompleksleri için 10-60 saniyearasında bulundu. Fe(III), Ni(II), Co(III) ve Cu(II) Komplekslerin maksimum absorbpsiyonyaptığı dalga boyları (λmax) sırasıyla 490 nm, 504 nm, 510 nm ve 500 nm olarak bulundu.Kompleks oluşumu için en uygun pH değerleri Co-PAR için 5-8 aralığı, Fe-PAR için 4-6,5aralığı, Ni-PAR için 6-10 aralığı ve Cu-PAR için 6-9 aralığı olduğu belirlendi.Komplekslerin molar soğurma katsayıları (ε) Fe-PAR için 5,4x104 mol L-1 cm-1, Ni-PAR için 2,7x104 mol L-1 cm-1, Co-PAR için 6,5x104 mol L-1 cm-1 ve Cu-PAR için 4,2x104mol L-1 cm-1 olarak bulundu. UV-Visible detektörü kullanılarak C18 Luna ODS (250x4,6 mm5µ 100A) kolonunda optimize edilen kromatografik ayırma şartları; dalga boyu 500 nm, akışhızı 0.6 mL/dk, mobil faz bileşimi metanol/su/asetonitril/asetat çözeltisi (55/40/2,5/2,5 v/v),mobil faz pH'ı 5,3 olarak bulundu.Optimize edilen şartlarda yöntemin tayin sınırları Fe-PAR, Ni-PAR ve Co-PAR içinsırasıyla 4.45, 3.26, ve 1.86 µg L-1 olarak bulundu.Optimize edilen şartlarda HPLC ile bitki örneklerinde Fe(III), Ni(II), Co(III)iyonlarının tayinleri gerçekleştirildi.

Özet (Çeviri)

The trans metal ions such as Fe(III), Ni(II) and Co(III) were materialized by highperformance liquid chromatography (HPLC) analyses in various plants by preparingcomplexes with 4-(2- pyridiylazo) resorcinol (PAR) ligand.The suitable conditions to prepare complex with PAR ligand of Fe(III), Ni(II),Co(III) and Cu(II) ions are investigated. The stoichiometries of complexes that formed ionsabove mentioned with PAR were determined that [Metal]/[Ligand] is 1:2 for Fe(III), Ni(II),Co(III) and is 1:1 for Cu ions by using mol rates and job method. Complex formationperiods for Fe(III), Ni(II), Co(III) and Cu(II) complexes were found as 10-60 seconds inpresence of methanol-water.The wavelengths of maximum absorbance for Fe(III), Ni(II), Co(III) and Cu(II)complexes were determined as 490 nm, 504 nm, 510 nm and 500 nm, respectively. Themost suitable pH values of complex formation for Co-PAR, Fe-PAR, Ni-PAR and Cu-PARwere determined in 5-8, 4-6.5, 6-10 and 6-9 range, respectively.The molar absorption coefficients of complexes for Fe-PAR, Ni-PAR, Co-PAR andCu-PAR were found as 5,4x104, 2,7x104 6,5x104, , 4,2x104 mol L-1 cm-1, respectively. ThepH of mobil phase was determined as 5,3 under chromatographycal separation conditionsoptimized in column C18 5µ 100A Luna (250x4,6 mm) ODS by using UV-Visible detector:wave length 500 nm, flow rate 0,6 mL/min, mobile phase composition;methanol/water/acetonitrile/acetate solutionDetection limits of process for Fe-PAR, Ni-PAR and Co-PAR under optimizedconditions were found as 4.45, 3.26 and 1.86 µg.L-1, respectively. The analysis of Fe, Ni andCo ions in plant samples under optimized conditions were carried out by HPLC.

Benzer Tezler

  1. A highly selective and reusable colorimetric and turn-on fluorescent chemosensor based on rhodamine tethered aldehyde functional microspheres for the detection of Cu2+ and Hg2+ ions

    Cu2+ ve Hg2+ 'nın deteksiyonu için yüksek seçicilik gösteren rodamin tutturulmuş aldehit fonksiyonlu mikroküre esaslı kolorimetrik ve floresans“turn on”tekrar kullanılabilir kemosensörlerin hazırlanması

    PINAR ÖZMEN

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    İstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Nükleer rezonasta moleküler yapıların incelenmesi (yapısal faz geçiş kuramları üzerine bir inceleme)

    Başlık çevirisi yok

    ABDURRAHMAN ANDİÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  5. Bazı yer ve sırık fasulye çeşitlerinde optimal melezleme şartlarının tespiti üzerine bir araştırma

    Başlık çevirisi yok

    TÜRKAN KOÇLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    Yükleniyor...