Çeşitli biyolojik ve çevre örneklerindeki kobalt, bakır, nikel ve demir gibi eser elementlerin yüksek performanslı sıvı kromatografisi ile tayini
The determination of trace elements as cobalt, copper, nickel and iron in different biologycal and environmental samples with high performance liquid chromatograpy
- Tez No: 200193
- Danışmanlar: DOÇ.DR. ALİ ÖLÇÜCÜ
- Tez Türü: Doktora
- Konular: Biyokimya, Kimya, Biochemistry, Chemistry
- Anahtar Kelimeler: HPLC, Eser Element, 4-(2-piridilazo) resorsinol, UV-Visible, Demir, Nikel, Kobalt, PAR, Resorsinol, HPLC, Trace Element, 4-(2-pyridylazo)-resorcinol, UV-Visible, Iron, Nickel, Cobalt, PAR, Resorcinol
- Yıl: 2007
- Dil: Türkçe
- Üniversite: Fırat Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 148
Özet
Yüksek performanslı sıvı kromatografisi (HPLC) ile Fe(III), Ni(II) ve Co(III) gibigeçiş metal iyonlarının, 4-(2-piridilazo) resorsinol (PAR) ligandı ile komplekslerihazırlanılarak çeşitli bitkilerdeki analizleri gerçekleştirildi..Fe(III), Ni(II), Co(III) ve Cu(II) iyonlarının PAR ligandı ile kompleks hazırlamaincelendi. Bahsedilen iyonların PAR ile oluşturdukları komplekslerin şartlarıstokiyometrileri mol oranı ve job yöntemi kullanılarak Fe(III), Ni(II), Co(III) iyonları için(Metal/Ligand) 1:2, Cu(II) iyonu için 1:1 olduğu bulundu. Kompleks oluşum sürelerimetanol-su ortamında Fe(III), Co(III), Ni(II) ve Cu(II) kompleksleri için 10-60 saniyearasında bulundu. Fe(III), Ni(II), Co(III) ve Cu(II) Komplekslerin maksimum absorbpsiyonyaptığı dalga boyları (λmax) sırasıyla 490 nm, 504 nm, 510 nm ve 500 nm olarak bulundu.Kompleks oluşumu için en uygun pH değerleri Co-PAR için 5-8 aralığı, Fe-PAR için 4-6,5aralığı, Ni-PAR için 6-10 aralığı ve Cu-PAR için 6-9 aralığı olduğu belirlendi.Komplekslerin molar soğurma katsayıları (ε) Fe-PAR için 5,4x104 mol L-1 cm-1, Ni-PAR için 2,7x104 mol L-1 cm-1, Co-PAR için 6,5x104 mol L-1 cm-1 ve Cu-PAR için 4,2x104mol L-1 cm-1 olarak bulundu. UV-Visible detektörü kullanılarak C18 Luna ODS (250x4,6 mm5µ 100A) kolonunda optimize edilen kromatografik ayırma şartları; dalga boyu 500 nm, akışhızı 0.6 mL/dk, mobil faz bileşimi metanol/su/asetonitril/asetat çözeltisi (55/40/2,5/2,5 v/v),mobil faz pH'ı 5,3 olarak bulundu.Optimize edilen şartlarda yöntemin tayin sınırları Fe-PAR, Ni-PAR ve Co-PAR içinsırasıyla 4.45, 3.26, ve 1.86 µg L-1 olarak bulundu.Optimize edilen şartlarda HPLC ile bitki örneklerinde Fe(III), Ni(II), Co(III)iyonlarının tayinleri gerçekleştirildi.
Özet (Çeviri)
The trans metal ions such as Fe(III), Ni(II) and Co(III) were materialized by highperformance liquid chromatography (HPLC) analyses in various plants by preparingcomplexes with 4-(2- pyridiylazo) resorcinol (PAR) ligand.The suitable conditions to prepare complex with PAR ligand of Fe(III), Ni(II),Co(III) and Cu(II) ions are investigated. The stoichiometries of complexes that formed ionsabove mentioned with PAR were determined that [Metal]/[Ligand] is 1:2 for Fe(III), Ni(II),Co(III) and is 1:1 for Cu ions by using mol rates and job method. Complex formationperiods for Fe(III), Ni(II), Co(III) and Cu(II) complexes were found as 10-60 seconds inpresence of methanol-water.The wavelengths of maximum absorbance for Fe(III), Ni(II), Co(III) and Cu(II)complexes were determined as 490 nm, 504 nm, 510 nm and 500 nm, respectively. Themost suitable pH values of complex formation for Co-PAR, Fe-PAR, Ni-PAR and Cu-PARwere determined in 5-8, 4-6.5, 6-10 and 6-9 range, respectively.The molar absorption coefficients of complexes for Fe-PAR, Ni-PAR, Co-PAR andCu-PAR were found as 5,4x104, 2,7x104 6,5x104, , 4,2x104 mol L-1 cm-1, respectively. ThepH of mobil phase was determined as 5,3 under chromatographycal separation conditionsoptimized in column C18 5µ 100A Luna (250x4,6 mm) ODS by using UV-Visible detector:wave length 500 nm, flow rate 0,6 mL/min, mobile phase composition;methanol/water/acetonitrile/acetate solutionDetection limits of process for Fe-PAR, Ni-PAR and Co-PAR under optimizedconditions were found as 4.45, 3.26 and 1.86 µg.L-1, respectively. The analysis of Fe, Ni andCo ions in plant samples under optimized conditions were carried out by HPLC.
Benzer Tezler
- A highly selective and reusable colorimetric and turn-on fluorescent chemosensor based on rhodamine tethered aldehyde functional microspheres for the detection of Cu2+ and Hg2+ ions
Cu2+ ve Hg2+ 'nın deteksiyonu için yüksek seçicilik gösteren rodamin tutturulmuş aldehit fonksiyonlu mikroküre esaslı kolorimetrik ve floresans 'turn on' tekrar kullanılabilir kemosensörlerin hazırlanması
PINAR ÖZMEN
Yüksek Lisans
İngilizce
2019
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
DOÇ. DR. BÜNYAMİN KARAGÖZ
- Polisakkarit kaplı titanyum nanopartiküller kullanılarak bazı ağır metallerin giderilmesi
Removal of some heavy metals using starch coated titanium nanoparticles
CEREN KUZNEK ARSLAN
Yüksek Lisans
Türkçe
2016
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. MUSTAFA ÖZCAN
DOÇ. DR. ASLI BAYSAL
- Peptit bağlı altın nanoparçacıklar kullanarak bazı eser elementlerin ayrılması
Separation of some trace elements using peptide bound gold nanoparticles
GİZEM GEDİK
Yüksek Lisans
Türkçe
2013
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
PROF. DR. SÜLEYMAN AKMAN
- Bazı gıda örneklerindeki alüminyumun florometrik yöntem ile tayini
Determination of aluminum in some food samples of with fluorometric method
ESRA YILDIZ
- Çevre örneklerindeki alifatik ve aromatik aminlerin iyon çifti ekstraksiyonu ve GC-MS metoduyla belirlenmesi
Ion-pair extraction and GC-MS determination of aliphatic and aromatic amines in the environmental samples
ŞEVKET ATA
Yüksek Lisans
Türkçe
2004
KimyaZonguldak Karaelmas ÜniversitesiKimya Ana Bilim Dalı
Y.DOÇ.DR. MEHMET AKYÜZ