Polimer jel dozimetre ve manyetik rezonans görüntüleme yardımıyla İridyum192 yüksek doz oranlı brakiterapi kaynaklarının 3boyutlu doz dağılımının analizi

The use of polimer gel dosimetry and magnetic resonance imaging for the analysis of 3D dose distrubitions of high dose rate Ir-192 sources

  1. Tez No: 224271
  2. Yazar: ÖZNUR ŞENKESEN
  3. Danışmanlar: DOÇ. DR. İSMAİL ÖZBAY
  4. Tez Türü: Doktora
  5. Konular: Onkoloji, Oncology
  6. Anahtar Kelimeler: Normoksik polimer jel, Jel dozimetri, brakiterapi, İridyum-192, Normoxic polimer gel, Gel dosimetry, Brachytherapy, Iridyum192
  7. Yıl: 2008
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 104

Özet

Brakiterapi kaynaklarının kullanılmakta olan deneysel dozimetri olanakları sınırlıdır. Kullanılan dozimetrenin özelliğine bağlı olarak, dozimetrenin kendisinin yol açtığı radyasyon akısındaki değişiklikler ve çözünürlüğünün düşüklüğü üç boyutlu (3D) olarak bilgi kaybına ve hatalara neden olmaktadır. Yüksek doz oranlı (YDO) brakiterapi uygulamalarında kullanılan İridyum-192 kaynaklarının etrafında çok yüksek dozların olması ve kaynaktan uzaklaştıkça çok hızlı doz düşüşü doz dağılımlarının kalite kontrolünü güçleştirir. Bu çalışmada polimer normoksik jel dozimetri yöntemi ile İridyum-192 brakiterapi kaynaklarının 3 boyutlu doz dağılımları iki ayrı jel fantom hazırlanarak, iki farklı plan için elde edilmiştir. Bilgisayarlı tedavi planlama sisteminde tek kaynak pozisyonu ve 3cm uzunluğunda kaynak boyu için iki ayrı plan hazırlanmıştır. Hesaplanan duruş pozisyonları ile jel fantom ışınlanarak, ışınlanan fantomun Manyetik Rezonans (MR) görüntüleri alınmıştır. Görüntüler MATLAB bilgisayar yazılımı ile analiz edilerek 1mm çözünürlük ile elde edilen doz dağılımı ve profiller, tedavi planlama sistemi (TPS) ile hesaplanarak elde edilen doz dağılımı ve profil değerleri ile karşılaştırılmıştır. Tek duruş pozisyon tanımlanarak ışınlanan nokta kaynak doz dağılımları için hesaplanan ve ölçülen %70,%50,%30 profil genişlikleri arasındaki farkın standart sapma değerleri sırasıyla x düzlemi için 1,05, 1,28, 0,78mm, y düzlemi için 0,68, 0,65, 0,5mm, z düzlemi için 0,83, 1,54, 1,37mm, kaynak boyu 3cm olarak hesaplanan ve ölçülen %70,%50,%30 profil genişlikleri arasındaki farkın standart sapma değerleri sırasıyla x düzlemi için 0,96, 1,43, 0,73mm, y düzlemi için 1,26, 2,12, 2,92mm, z düzlemi için 5,13, 1,6, 1,91mm olarak tespit edilmiştir. Sonuçlar jel dozimetre ve TPS verilerinin uyumlu olduğunu göstermiştir. Bu uyum brakiterapi kaynaklarının jel dozimetri yöntemi ile 3D doz dağılımlarının elde edilebilmesini ve TPS'lerinin 3D doğrulamasında kullanılabilirliğini göstermektedir.

Özet (Çeviri)

Experimental dosimetry resources used for brachytherapy sources are limited. Depending on the features of the dosimetry, the changes in radiation flow that is caused by the dosimetry itself and low resolution leads to three dimensional (3D) information loss and errors. Iridium-192 sources are used in high dose rate (HDR) brachytherapy, high doses around the Iridium-192 sources and the steep dose gradient make the dose distribution quality assurance difficult.In this study, 3D dose distributions of the Iridium-192 brachytherapy sources were obtained using the polimer normoxic gel dosimetry method in two different gel phantoms and they were calculated for two different plans. Two different plans were prepared with the treatment planning system, one of them for one dwell position, the other one for 3 cm source length.The gel phantom was irradiated for the calculated dwell positions and the MRI scans of the radiated phantom were obtained. The images were analysed with MATLAB software and the dose distributions and profiles that were derived with 1 mm resolution were compared with the dose distributions and profiles that were calculated by the treatment planning system.The differences of standart deviation values between the 70%, 50%, 30% profile widths, that were calculated and measured for the point source dose distributions that were obtained with describing one dwell position, were 1,05, 1,28, 0,78mm for x plane, 0,68, 0,65, 0,5mm for y plane, 0,83, 1,54, 1,37mm for z plane, respectively. The differences of standart deviation values between the 70%, 50%, 30% profile widths, that were calculated and measured for 3 cm source length were 0,96, 1,43, 0,73mm for x plane, 1,26, 2,12, 2,92mm for y plane and 5,13, 1,6, 1,91 mm for z plane.There was good agreement between the gel dosimetry and treatment planning system results. This correlation shows that the gel dosimetry method can be used to obtain 3D dose distributions and 3D verification of treatment planing systems.

Benzer Tezler

  1. Cyberknife synchrony® solunum takip sisteminin polimer jel dozimetre ile üç boyutlu performans analizi

    Three dimensional performance analysis of cyberknife synchrony® respiratory tracking system using polymer gel dosimeter

    MERYEM CANSU ŞAHİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Fizik ve Fizik MühendisliğiHacettepe Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. PERVİN HÜRMÜZ

  2. Yeni bir polimer jel dozimetrinin geliştirilmesi

    Development of a new polymer gel dosimetry

    TÜRKAN ALKAN

    Doktora

    Türkçe

    Türkçe

    2024

    Radyasyon OnkolojisiDokuz Eylül Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. AYŞEGÜL YURT

  3. Cyberknife® robotik radyocerrahi cihazında magıc polimer jel dozimetre ile küçük alan dozimetrisinin incelenmesi

    Investigation of small field dosimetry with magic polymer gel dosimeter in cyberknife® robotic radiosurgery device

    MEHMET FAZIL ENKAVİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik MühendisliğiHacettepe Üniversitesi

    Radyoterapi Fiziği Bilim Dalı

    PROF. DR. MUSTAFA CENGİZ

  4. Radyoterapi hastalarında radyasyon doz dağılımlarının deneysel olarak üç boyutlu şekilde belirlenebilmesi için yeni doku eşdeğeri jel dozimetrelerin geliştirilmesi

    Development of new tissue equivalent gel dosimeter to experimently determine three-dimensional radiation dose distributions in radiotherapy patients

    ELİF BERNA ÇALI

    Doktora

    Türkçe

    Türkçe

    2023

    Radyasyon OnkolojisiAtatürk Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    DOÇ. DR. MUSTAFA ERDEM SAĞSÖZ

  5. 3-d gamma knife dose distribution by normoxic gel dosimetry near tissue inhomogeneties

    Doku inhomojenite yakınlarında üç boyutlu gamma knife doz dağılımının normoksik jel dozimetre ile incelenmesi

    FATİH İŞBAKAN

    Doktora

    İngilizce

    İngilizce

    2005

    BiyomühendislikBoğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. YEKTA ÜLGEN