Taşkın preparasyonlarda dentin matriksi seviyelendirmesi ve dolgusunda farklı apikal eğelerin etkinliği
Approximation of different apical files to predetermined level in overinstrumented root and effects on apical seal
- Tez No: 225511
- Danışmanlar: PROF. DR. TAYFUN ALAÇAM
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Tri Auto ZX, dentin matriksi, taskın preparasyon, mikrosızıntı, Tri Auto ZX, dentinal matrix, overextended preparation, microleakage
- Yıl: 2007
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu arastırma ex vivo aljinat test model sisteminde, Tri Auto ZX ile birlikte kullanılan farklı apikal egelerle olusturulan dentin matriksi seviyelerinin ve apikal mikrosızıntılarının gutta perka ve AH Plus kullanılarak degerlendirilmesi amacıyla yapıldı. ki yüz yirmi bes alt keser dis 25 numaralı K tipi ege ile apikal foramenden 1 mm taskın olarak prepare edildi. Arastırmanın birinci bölümünde, 80 dis 4 gruba bölündü. Daha sonra gruplar, her birinde 10 dis bulunan 2 alt gruba ayrıldı. Apikal preparasyon için seçilen enstrümanlar Lightspeed, Hero Apical, S Apex ve el egeleriydi. Apeks bulucu 0,5 ve 1 mm'ye ayarlandı. Mekanik enstrümantasyon tamamlandıktan sonra apikal sonlanmadan apikal preparasyon sınırına kadar olan mesafe, dirençölçer ve stereomikroskop kullanılarak parmak sondu (# 25) ile iki arastırmacı tarafından ölçüldü. ki arastırmacının ölçümleri arasında belirgin istatistiksel fark bulunamadı (p<0,05; t testi). Preparasyonlar, Tri Auto ZX'in iki ayarında da amaçlanan seviyeden daha kısa bulundu. stenen seviyeye en yakın grup, el egeleri olarak bulundu. Dogruluk sıralaması 0,5 mm'de el egeleri, Hero Apical, Lightspeed, S Apex olarak belirlendi. S Apex, el egeleri ve Hero Apical'den belirgin olarak farklı bulundu. Dogruluk sıralaması 1 mm'de el egeleri, Lightspeed, Hero Apical, S Apex olarak saptandı. El egeleri ile S Apex arasında ve S Apex ile Hero Apical arasında belirgin fark bulundu (Tamhane testi). Arastırmanın ikinci bölümünde, kalan 145 diste mekanik islemler tekrarlandı. Pozitif kontrol grubu ve bir grupta daha apikal stop olusturulmadı. Kanalların tümü dolduruldu. Pozitif kontrol bos bırakıldı. Apikal sızıntı ölçüldü ve gruplar arasında anlamlı fark bulunamadı (ANOVA). Dönen apikal preparasyon el preparasyonuna göre avantajlı bulunmadı ve dentin matriksi preparasyonu mikrosızıntıyı azaltmadı.
Özet (Çeviri)
The aim of this study was to evaluate the level of apical dentinal matrix formed by different apical files used with TriAutoZX in ex vivo alginate test model system and to measure the apical microleakage using gutta percha and AH Plus sealer. Two hundred twenty five mandibular incisor teeth were overinstrumented using # 25 K-file extruding 1 mm from the apical foramen. In the first part of the study, 80 teeth were divided into 4 groups. The groups were then subdivided to two groups of 10 teeth each. Chosen instruments for apical preparation were Lightspeed, HeroApical, S Apex and stainless steel hand instruments. The apex locator was set to 0.5 and 1 mm. After completion of mechanical instrumentation, distance from apical terminus to apical preparation border were measured by finger plugger(# 25) by using ohmmeter and stereomicroscope by two examiners. There was no significant difference between the examiners (p<0.05; t test). Preparations were found shorter then aimed level with all rotary groups at both settings of TriAutoZX. Hand files were found to be closest groups to the exact level. The order of accuracy of system for 0.5 mm were hand file>HeroApical>Lightspeed>S Apex. S Apex was significantly differrent from hand file and HeroApical. The order of accuracy for 1 mm. was hand file>Lightspeed>HeroApical>S Apex. Significant difference was found between hand file and S Apex and between hand file and Hero Apical. In the second part of the study, mechanical procedures were repeated for the remaining 145 roots. For one group and positive and control group apical stop was not prepared. All the canals were obturated. The positive control group kept unobturated. The apical leakage was measured and no significant difference was found between the groups. Rotary apical preparation had no advantage over hand preparation and dentinal matrix preparation didn?t reduce microleakage.
Benzer Tezler
- Taşkın yatak hidromekaniğinin matematiksel modellemesi ve çözümü
Mathematical modelling of spouted bed hydrodynamics and its solution
KÜRŞAD DÜNDAR
Doktora
Türkçe
1988
Makine MühendisliğiGazi ÜniversitesiMakine Eğitimi Ana Bilim Dalı
DOÇ. DR. BİROL KILKIŞ
- Taşkın yataklı kesitlerde ana yatak-taşkın yatağı akımlarının etkileşimi
Interaction of main channel and flood plain flows
TANJU AKAR
- Menfezlerin projelendirilmesi için taşkın hesap metodları
Flood calculation methods for projecting culverts
AYŞE HÜLYA AŞKAN
- Akarsu kesitlerinde taşkın ötelenmesi
Flood routing in any section of the river
HAVVA UZYÖNÜM
Yüksek Lisans
Türkçe
1996
İnşaat MühendisliğiSüleyman Demirel Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. ALİ DOĞAN
- Taşkın frekans analizinde kullanılan değişik dağılımların Konya Havzası yıllık pik akım serilerine uygulanıp karşılaştırılması
Başlık çevirisi yok
NACİ BÜYÜKKARACIĞAN
Yüksek Lisans
Türkçe
1997
İnşaat MühendisliğiSelçuk Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ERCAN KAHYA