Precise tedavi planlama sisteminin 6 MV ve 18 MV foton enerjilerinde toraks tümörleri tedavisindeki doz dağılımının film dozimetri, elektronik portal görüntüleme ve in-vivo dozimetrik sistemleriyle kalite kontrolü
Quality control of dose distribution of Precise treatment planning system of photon energies 6 MV and 18 MV for thorax tumors treatment by using film dosimetry, electronic portal imaging and in-vivo dosimetric systems.
- Tez No: 225628
- Danışmanlar: DOÇ. DR. GÖKHAN ÖZYİĞİT
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Oncology, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2008
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Klinik Onkoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 98
Özet
Radyoterapide hedeflenen başarıya ulaşmanın yolu, yapılan tedavi planlamalarının doğru olarak uygulanmasından geçmektedir. Bu nedenle tedavi planlama sistemlerinin kalite kontrollerinin yapılması büyük bir önem taşır. Bu çalışmada amaç Precise tedavi planlama sistemini kullanarak toraks tümörleri için elde edilen tedavi planlamalarındaki doz dağılımlarını, diyot, termolüminesans dozimetri (TLD), film dozimetrik ölçüm sistemleri ile yapılan ölçümlerden elde edilen sonuçlarla karşılaştırmak ve tedavi planlama sisteminin kalite kontrolünü sağlamaktır. Çalışmada ilk olarak ölçümlerde kullanılacak olan diyot, TLD ve film dozimetri sistemlerinin kalibrasyonları yapılmıştır. Daha sonra Alderson rando fantomun bilgisayarlı tomografi görüntüleri çekilerek tedavi planlama sistemine aktarılmıştır. Rando fantomda toraks bölgesinde belirlenen üç ayrı hedef hacim için tedavi planlamaları yapılmıştır. Tümör ve kritik organ dozları için ölçüm alınacak noktalar tedavi planlama sisteminde belirlenmiştir. Tedavi cihazında ilgili noktalar için dozlar diyot, TLD ve film kullanılarak ölçülmüştür. Her ölçüm öncesi rando fantom üzerindeki tedavi alanlarının doğruluğu elektronik portal görüntüleme cihazı ile film çekilerek kontrol edilmiştir. Ölçüm sonuçlarımız tedavi planlama verileri ile karşılaştırıldığında genellikle ± %5 sınırları içinde olup literatür ile uyumludur. Ancak doz cevabı, kama filtre bağımlılığı gibi dozimetri sistemlerinin özeliklerinden kaynaklanan veya ölçümde kullanılan dozimetri sistemlerinin rando fantom üzerine yerleştirilmesi sırasında yapılan hatalar nedeniyle ± %5 dışında doz farkı oluşan noktalar gözlenmiştir. Bununla beraber yoğunluk ayarlı radyoterapi gibi daha hassas tedavi planlarında kullanmış olduğumuz in-vivo dozimetri ölçüm sonuçlarına daha dikkatli yaklaşılması gerektiği düşüncesindeyiz.
Özet (Çeviri)
The application of treatment plans correctly tends to reach to the success in radiotherapy. Thus, the quality control of treatment planning has a big importance. The aim of this study is to compare the dose distribution results of thorax tumors obtained from Precise treatment planning system (TPS) with the results of film, diode and thermoluminescence dosimetry (TLD) measurements and ensuring the quality control of the treatment planning system. The film, diode and TLD dosimeters that were used in the measurement were calibrated at the beginning of the study. Then the Alderson rando phantom was digitally imaged by using a Computerized Tomography and the images were transferred to the TPS. The treatment plans were computed at the thorax region of rando phantom for three different defined target volumes. The measurement points for target and critical organ doses were defined at the TPS. The doses for defined points were measured in the rando phantom by using diodes, TLDs and films at the treatment machine. All treatment fields of rando phantom were controlled by taking images from electronic portal imaging device before each dosimetric measurement. The measurement results were in the range of ±5 % with respect to the treatment planning datas and were congruent with the literature. However, at some points more than ± 5% dose differences were observed due to the dosimetric systems characterization like the dose response, wedge filter dependency and the setup errors during inserting the dosimetric systems into the rando phantom. Nevertheless, one should take care of the results of in vivo dosimetry while controling the much more sensitive radiotherapy plans like intensity modulated radiotherapy.
Benzer Tezler
- Doğrusal hızlandırıcı tedavi cihazında elde edilen farklı enerjili foton demetlerinden, üç boyutlu tedavi planlama sistemi için gerekli ölçümlerin alınması
Getting measurements, of whıch are necessary for three diamensional treatment planning system, from the photon beams with different energies that are obtained from linear accelerator treatment machine
FATMA AKYOL
- Prostat kanserinin konformal radyoterapi ve cyberknife robotik radyocerrahi ile tedavilerinin dozimetrik olarak karşılaştırılması
Dosimetric comprasion of treatments for prostate cancer with conformal radiotherapy and cyberknife robotic radiosurgery
ŞABAN BERAT ARAL
Yüksek Lisans
Türkçe
2013
BiyofizikAnkara ÜniversitesiSağlık Fiziği Ana Bilim Dalı
DOÇ. DR. BAHAR DİRİCAN
- Rektum kanseri tedavisinde yoğunluk ayarlı radyoterapi planlamaları ile 3 boyutlu konformal radyoterapi planlamalarının doz dağılımlarının karşılaştırılması
Comparison of dose distribution with intensity modulated radiation therapy and 3 dimensional conformal radiotherapy for rectum cancer
ŞULE BAZ ÇİFCİ
Yüksek Lisans
Türkçe
2011
OnkolojiHacettepe ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
PROF. DR. MUSTAFA CENGIZ
- CO-60 ve lineer hızlandırıcı tedavi cihazları ile radyoterapi uygulanan T1-T2 glottik larenks kanseri hastalarının aldığı dozların farklı dozimetrik sistemler kullanılarak incelenmesi
Başlık çevirisi yok
AHMET SATUK KARAGÖZ
Yüksek Lisans
Türkçe
2016
OnkolojiAkdeniz ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
YRD. DOÇ. DR. YİĞİT ÇEÇEN
- Kranyospinal ışınlama tekniklerinin yüzüstü ve sırtüstü pozisyonlarda karşılaştırılması
Comparison of craniospinal irradiation techniques in prone and supine positions
AHMET KÜRŞAT ÖZKAN
Yüksek Lisans
Türkçe
2005
OnkolojiHacettepe ÜniversitesiRadyoterapi Fiziği Ana Bilim Dalı
PROF. DR. ENİS ÖZYAR