Geri Dön

Kennedy class II vak'alarında kullanılan bilateral ve unilateral protez tasarımlarının retansiyon ve stabilite bakımından mukayeseleri

Başlık çevirisi mevcut değil.

  1. Tez No: 23970
  2. Yazar: VACİDE AKGÖK
  3. Danışmanlar: PROF. DR. MUTAHHAR ULUSOY
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 1992
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 89

Özet

80 SUMMARY The comparison of bilateral and unilateral prosthesis designs used in Kennedy Class- II cases from the view point of retention and stability. Various bilateral and unilateral prosthesis designs used in Kennedy Class-II unilate¬ ral free end cases have been compared for their retention and stability in this investigation. Nine mandibular models of Kennedy Class-II partially edentulous case have been prepared from the photoelastic material for the stability and stress analysis tests. Three groups of unilateral and six groups of bilateral framework designs were made on the models and the castings were done and finished with the routine techniques. These models were loaded under special conditions for the three dimensional stress analysis. in this technique, parallel sections of models were analysed under polarized light in Polariscope and then the photographs were taken. Number of fringes on the photographs were counted and evaluated. in addition the results were shown with graphics and compared with each other. On the other hand, Kennedy Class-II mandibular model from acrylic resin was pre¬ pared and the framevvork designs rneııtioned above were done for the retention tests. Each framevvork was tested ten times to measure tensile forces and to define the strength of the force resisting to remove the prosthesis and the results were evaluated statistically.

Özet (Çeviri)

80 SUMMARY The comparison of bilateral and unilateral prosthesis designs used in Kennedy Class- II cases from the view point of retention and stability. Various bilateral and unilateral prosthesis designs used in Kennedy Class-II unilate¬ ral free end cases have been compared for their retention and stability in this investigation. Nine mandibular models of Kennedy Class-II partially edentulous case have been prepared from the photoelastic material for the stability and stress analysis tests. Three groups of unilateral and six groups of bilateral framework designs were made on the models and the castings were done and finished with the routine techniques. These models were loaded under special conditions for the three dimensional stress analysis. in this technique, parallel sections of models were analysed under polarized light in Polariscope and then the photographs were taken. Number of fringes on the photographs were counted and evaluated. in addition the results were shown with graphics and compared with each other. On the other hand, Kennedy Class-II mandibular model from acrylic resin was pre¬ pared and the framevvork designs rneııtioned above were done for the retention tests. Each framevvork was tested ten times to measure tensile forces and to define the strength of the force resisting to remove the prosthesis and the results were evaluated statistically.

Benzer Tezler

  1. Endodontik tedavili dişlerin hareketli bölümlü protezlerde destek olarak kullanılmasında oluşan stresslerin analizi

    Başlık çevirisi yok

    BÜLENT ULUDAĞ

    Doktora

    Türkçe

    Türkçe

    1988

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. GÜLŞEN CAN

  2. Üst çene ana bağlayıcıların optimizasyonu

    Optimization of maxillary major connectors

    İPEK AÇIKBAŞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SERHAN AKMAN

  3. Kısmi dişsizlik durumlarında görülen temporomandibular eklem rahatsızlıklarının protetik tedaviden önce ve sonra manyetik rezonans görüntüleme yöntemi ile değerlendirilmesi

    The Evaluation of temporomandibular joint disorders observeding the case of partial edentulous through magnetic resonance imagine before and after prosthetic rehabilitation

    KORHAN BÖKE

    Doktora

    Türkçe

    Türkçe

    2000

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. YÜKSEL TÜRKÖZ

  4. Hareketli bölümlü protezlerde hassas tutucuların tutuculuk özellikleri

    Retention properties of precision attachments in the removable partial dentures

    BARANSEL ÖZMUMCU

    Doktora

    Türkçe

    Türkçe

    2008

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. GÜLŞEN CAN

  5. Parsiyel protezlerde ölçü metodlarının karşılaştırılması

    Başlık çevirisi yok

    İSLAM İSLAMOĞLU

    Doktora

    Türkçe

    Türkçe

    1986

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NURİ MUĞAN