Geri Dön

Immobilization of hirudin on surface of PTFE to increase its blood compatibility

PTFE yüzyelere kan uyumluluklarını arttırmak için hirudin tutuklanması

  1. Tez No: 252018
  2. Yazar: SAKİP ÖNDER
  3. Danışmanlar: DOÇ. DR. KÜRŞAT KAZMANLI, YRD. DOÇ. DR. FATMA NEŞE KÖK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Biyoteknoloji, Polimer Bilim ve Teknolojisi, Bioengineering, Biotechnology, Polymer Science and Technology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2009
  8. Dil: İngilizce
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İleri Teknolojiler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 79

Özet

Kan uyumluluğu yapay kan damarı, yapay kalpler ve kateterler gibi kan ile temas eden biyolojik malzemeler için gerekli bir özelliktir. Biyolojik malzemelerin yüzeylerinde oluşan pıhtılaşma bu malzemelerin kullanımlarını engelleyen en önemli faktörlerden birisidir. Malzemelerin yüzeylerinde yapılacak olan değişiklikler ile bu problem büyük oranda çözülebilmektedir.Bu çalışmanın amacı biyomalzeme olarak kullanılabilen PTFE yüzeylerin, önce hidrojen plazma ile aktif hale getirilmesi, daha sonrada akrilamit monomerlerinin ve sülüklerden izole edilen ve pıhtılaşmayı engelleyen bir enzim olan hirudinin yüzeye tutuklanmasıdır. Çalışmanın ilk kısmında, farklı PTFE yüzeylerinde temas açısı ölçümleri ve ATR-FTIR analizleri yapılarak plazma uygulaması için en uygun koşullar belirlendi. Hidrojen plazma koşullarında yapılan optimizasyon ile PTFE yüzeylerin temas açısı 130 ? den 59 ? kadar düşürülmüştür. Daha sonra, yüzeylere önce akrilamit çözeltisi ( %25 w/v; etanol/aseton ( %50 v/v)) , sonrada monomer aşılaması için (1 dk-50 W-13 Pa) Argon plazma uygulanmıştır.Yapılan temas açısı ölçümlerinde açısının 33 ? kadar düştüğü, ATR-FTIR analizlerinde ise 1665 cm-1 civarında amid gruplarının varlığı görülmüştür. Çalışmanın ikinci kısmında EDC/NHS aktivasyonu ile hirudin yüzeydeki amide gruplarına bağlanmıştır. Daha sonra trombus oluşumu (Kinetik Model) testi uygulanarak hirudinin aktivitesi ölçülmeye çalışıldı. Sonuçlar normal PTFE yüzeyleri ile karşılaştırıldığında pıhtılaşmada ciddi bir azalmanın olduğu, hatta bazı ölçümlerde neredeyse hiç pıhtılaşma olmadığını gözlenmiştir.Sonuç olarak, plazma yöntemine dayalı monomer aşılama ve hirudin tutuklama yöntemiyle PTFE malzemenin yüzeyinin kan uyumluluğunu arttırmayı başardık ve yapay kan damarı, kateter vb. gibi medikal uygulamalarda kullanılabilecek biyo malzemelere bir alternatif elde ettik.

Özet (Çeviri)

Blood compatibility is an essential feature for blood-contacting biomaterials, namely blood vessel grafts, artificial heart and catheters. Surface induced thrombosis is one of the major causes for the failure of these biomaterials and can be minimized by altering the surface characteristics.The aim of this study is to increase the blood compatibility of polytetrafluoroethylene (PTFE), one of the preferred materials for this kind of applications, by a two-step procedure: Firstly, the surface was activated by hydrogen plasma followed by acrylamide attachment and secondly, hirudin, a potent antithrombogenic protein from leeches, was immobilized to the surface. The first part of the study involving the plasma treatment was optimized and different surfaces were characterized by water contact angle measurements and ATR-FTIR. It was seen that the contact angle of the PTFE was decreased from 130 ? to 59 ? by optimizing the hydrogen plasma treatment conditions. Then acrylamide solution (25 % w/v; in ethanol/acetone (50 % v/v)) was applied to the surface and subjected to argon plasma treatment (1 min-50 W-13 Pa) for monomer grafting. Water contact angle was further down to 33 ? and amide groups can be detected by ATR-FTIR analysis. In the second part, hirudin was attached to amide groups on PTFE surface by EDC/NHS activation. Then thrombogenicity (Kinetic Model) test was applied to detect hirudin activity. Test results showed that there is a serious decrease in the clot formation compared with the pristine PTFE samples. Even no clot formation observed in some cases.As a result, we increased blood compatibility of PTFE surfaces by plasma-induced monomer grafting and hirudin immobilization and obtained an alternative material to be used in medical applications such as vascular graft, catheters etc.

Benzer Tezler

  1. Laktaz enziminin immobilizasyonu

    Immobilization of lactase enzyme

    ONUR SARSAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    BiyokimyaMarmara Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. AYŞE OGAN

    DOÇ. DR. SERAP DEMİR

  2. Immobilization of lipase enzyme onto precipitated silica and synthesis of polycaprolactone

    Lipaz enziminin çöktürülmüş silika üzerine immobilizasyonu ve polikaprolakton sentezi

    NUREFŞAN GÖKALP

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    Biyokimyaİstanbul Teknik Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. FATOŞ YÜKSEL GÜVENİLİR

  3. Kuartz kristal yüzeyine protamin immobilizasyonu

    Immobilization of protamine to the surface of quartz crystal

    SEMİHA İREM AKAY

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    BiyomühendislikBaşkent Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MUSTAFA KOCAKULAK

  4. Üreaz enziminin Ca-Alginat üzerine immobilizasyon koşullarının incelenmesi

    Investigation of immobilization conditions of Urease on Ca-Alginate

    DİLA ÖRNEK ACAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    KimyaAdnan Menderes Üniversitesi

    Kimya Bölümü

    PROF. DR. A. ALEV KARAGÖZLER

  5. Lipaz enziminin immobilizasyonu ve aromatik esterlerin sentezinde kullanımı

    Immobilization of lipase enzyme and using for production of flavor esters

    ESRA GEZER

    Yüksek Lisans

    Türkçe

    Türkçe

    2009

    BiyokimyaMustafa Kemal Üniversitesi

    Kimya Ana Bilim Dalı

    YRD. DOÇ. DR. GÜL ÖZYILMAZ