Koklear implant kullanıcılarında gürültünün İşitsel P300 ve Eşleşmeyen Negativite üzerine etkisi
The noise effects n Auditory P300 and Mismatch Negativity of cochlear implantees
- Tez No: 267170
- Danışmanlar: PROF. DR. FERDA AKDAŞ
- Tez Türü: Doktora
- Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
- Anahtar Kelimeler: P300, EMN, koklear implant, BEAM, P300, MMN, cochlear implant, BEAM
- Yıl: 2010
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Kulak Burun Boğaz Hastalıkları Ana Bilim Dalı
- Bilim Dalı: Odyoloji ve Konuşma Bozuklukları Bilim Dalı
- Sayfa Sayısı: 146
Özet
Bu çalışmanın amacı, koklear implant kullanan kişilerde gürültünün ve gürültülü ortamda adaptif direksiyonel mikrofon kullanımının İşitsel P300 ve Eşleşmeyen Negativite [EMN (Mismatch Negativity-MMN)] üzerine etkisini incelemektir. P300 çalışması için koklear implant kullanan 35 kişi, EMN çalışması için 11 kişi çalışmaya katılmıştır. Kontrol grubu olarak aynı sayıda normal işiten denekler çalışmaya alınmıştır. Koklear implant kullananlarda en az bir yıllık implant kullanma deneyimi aranmıştır. P300 ve EMN cevaplarının kaydı için /da/ sık uyaran, /di/ seyrek uyaran olarak, şiddet seviyeleri 70 dB SPL olacak şekilde, katılımcıdan 1 metre uzakta 0º açı ile yerleştirilen hoparlörden verilmiştir. 80 dB SPL şiddet seviyesindeki konuşma gürültüsü (sinyal gürültü oranı -10 dB), katılımcıdan 1 metre uzakta 180º açı ile yerleştirilen hoparlörden verilmiştir. Tüm katılımcılarda sessiz ve gürültülü ortamlarda kayıt yapılmıştır. Koklear implant kullanan kişilerde gürültülü ortamda omnidireksiyonel mikrofon programı ve gürültülü ortamda adaptif direksiyonel mikrofon (BEAM) programı ile P300 ve EMN kayıtları yapılmıştır. İmplantlı grupta sessiz ortam kayıtları omnidireksiyonel mikrofon programı ile yapılmıştır.P2, N2 ve P3 dalga latansları, EMN tepe latansı, normal işitenlerde gürültülü ortamda, sessiz ortama göre istatistiksel anlamlı uzun olarak elde edilmiştir. Koklear implant kullanan grupta da benzer şekilde, gürültülü ortamda omnidireksiyonel mikrofon programı ile yapılan kayıtlarda, sessiz ortama göre P2, N2, P3 dalga latanslarının ve EMN tepe latanslarının istatistiksel anlamlı uzadığı tespit edilmiştir. Ancak gürültülü ortamda BEAM ile kayıt yapıldığında, P2,N2,P3 dalga latanslarında ve EMN tepe latanslarında sessiz ortama benzer şekilde istatistiksel anlamlı kısalma olduğu belirlenmiştir.Adaptif direksiyonel (BEAM) mikrofon sisteminin gürültülü ortamlarda kullanılması, koklear implantlı kullanıcılarının işitsel uyaranları bilinç ve bilinç eşiği seviyesinde ayırt etmelerini kolaylaştırmaktadır.
Özet (Çeviri)
The aim of this research was to examine the effects of noise on P300 and MMN responses of cochlear implantees and the possible benefit of BEAM in noisy situations and to compare these results with those of normal hearing subjects. Totally, 35 Freedom cochlear implant users were tested for P300 (35 implantees) and MMN (11 implantees). Same number of normal hearing subjects were also tested as control group.All cochlear implant subjects have been using their implants at least for one year. To record P300 and MMN, /da/ (as standart), /di/ (as deviant) stimulus were used. Speech stimuli were delivered at 70 dB SPL via loudspeaker from 1 m. distance at 0º angle. Speech noise was delivered at ?10 dB SNR via loudspeaker from 1 m. at 180º angle. All subjects were tested in quite and noisy conditions. In noisy condition, cochlear implant patients were tested with both omnidirectional microphone and adaptive directional (BEAM) microphone programme. In quite condition only omnidirectional microphone programme was used.In control group, P2, N2, P3 and MMN latencies were significantly longer in noisy than those of in quiet condition. Also in cochlear implant group, with omnidirectionel microphone programme P2, N2 and P3 and MMN latencies were significantly prolonged in noisy than those of in quiet condition. But in noisy condition with BEAM, a statistically significant decrease in the latency of P2, N2, P3 and MMN were observed. In cochlear implant group, there was no statistically significant difference in quiet and in noisy condition with BEAM.Cochlear implant users can easily discriminate the auditory stimuli at conscious and preconscious level in noisy conditions with adaptive directional (BEAM) microphone programme.
Benzer Tezler
- Koklear implant aktivasyonunun postüral stabilite üzerine etkisi
Effect of Cochlear İmplant Activation on Postural Stability
VOLKAN TUTAR
Yüksek Lisans
Türkçe
2020
Kulak Burun ve BoğazHacettepe ÜniversitesiOdyoloji Ana Bilim Dalı
DR. ÖĞR. ÜYESİ MERVE BATUK
- Bilateral koklear implantlı çocuklarda ses lokalizasyonu üzerinde baş hareketlerinin etkisinin araştırılması
Investigation of the effect of head movements on sound localization in children with bilateral cochlear implants
NAZİRE İREM KARAKÜLÜK
Yüksek Lisans
Türkçe
2024
Kulak Burun ve BoğazHacettepe ÜniversitesiOdyoloji Ana Bilim Dalı
DOÇ. DR. MERVE BATUK
- İşitme kayıplı çocuk ve ergenlerin dinleme ve anlama becerilerinin değerlendirilmesi
Evaluation of listening and understanding skills of children and adolescents with hearing loss
ZEHRA ÇELEBİ
Yüksek Lisans
Türkçe
2022
Kulak Burun ve Boğazİstanbul Medipol ÜniversitesiOdyoloji Ana Bilim Dalı
DR. ÖĞR. ÜYESİ GÜL ÖLÇEK
- Yetişkin koklear implant (Biyonik kulak) kullanıcılarında sinyal gürültü oranının işitsel kortikal yanıtlara etkisinin araştırılması
Adults cochlear implant (Bionic ear) users, effect on signal to noise ratio in investigation of the auditory cortical responses
HALİDE ÇETİN KARA
Yüksek Lisans
Türkçe
2016
Kulak Burun ve Boğazİstanbul ÜniversitesiOdyoloji ve Konuşma Bozuklukları Ana Bilim Dalı
PROF. DR. AHMET ATAŞ
- İşitme kayıplı bireylerde, gürültü ve reverberasyonun uzaysal algı üzerine etkisi.
The effect of noise and reverberation on spatial perception in individuals with hearing loss
HALİDE ÇETİN KARA
Doktora
Türkçe
2020
Kulak Burun ve Boğazİstanbul Üniversitesi-CerrahpaşaOdyoloji Ana Bilim Dalı
PROF. DR. AHMET ATAŞ