Geri Dön

Ultrasonik radyasyon ile su ortamından amonyak azotunun uzaklaştırılması

Ammonia nitrogen removal from aqueous solution by ultrasonic radiation

  1. Tez No: 268646
  2. Yazar: EMRAH ÖZTÜRK
  3. Danışmanlar: YRD. DOÇ. DR. NAZİRE MAZLUM
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Amonyak azotu giderimi, sulu çözeltiler, sonikasyon, Ultrason, Ultrasonik inceleme, Ultrasonik yöntemler, Ammonia nitrogen removal, aqueous solutious, sonication, Ultrasound, Ultrasonic study, Ultrasonic methods
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Süleyman Demirel Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, yapay olarak hazırlanan solüsyonlarda amonyak azotu giderimi incelenmiştir. Çalışmada, başlangıç pH, başlangıç amonyum azotu konsantrasyonu, ultrason enerjisi ve ultrason sürelerinde testler yapıldı ve sonuçlara göre ultrasonun performansı değerlendirildi. Sonikasyon işlemi, ultrason ile %98 genlikte 1, 2 ve 5 dakika ultrason sürelerinde, asidik, nötr ve alkali şartlarda uygulandı. Test sonuçları, amonyak azotu giderimi asidik koşullar yerine alkali koşullarda daha etkili olduğunu gösterdi. Uygulanan testlerde yüksek giderimin pH 10 değerinde, başlangıç amonyak konsantrasyonu 20,7 mg N/l'de ve 5 dakika ultrason süresinde 10,9 mg N/l amonyak azotunun giderimi ile sağlandı. En yüksek giderim verimi pH 8,5 değerinde, 5 dakika ultrason süresinde ve %98 genlikte başlangıç konsantrasyonu 18,8 mg N/l olan örnekte gözlendi. 10 dakika ultrason süresi, %98 genlikte ve pH 8,5 değerinde %52,66 amonyak azotu giderim verimine ulaşıldı. Bu çalışmada, 5,6, 41,50, 84,50, 210 ve 415,60 mg N/l başlangıç amonyak azotu konsantrasyonunda testler yapıldı. Örneklere pH 8,5 değerinde ve 5 dakika ultrason uygulandı. Başlangıç konsantrasyonu 415,60 mg N/l olan örnekte 105 mg N/l amonyak azotu giderimi sağlandı. Çalışmada yüksek amonyak konsantrasyonlarına sahip numunelerde daha yüksek boyutta gideri gözlendi. Giderim verimi kısa ultrason süresi ve yüksek enerji uygulamasıyla sağlandı.

Özet (Çeviri)

In this study, removal of ammonia nitrogen in artificial prepared aqueous solutions, has been investigated. In the scape of the study, effects of initial pH, initial ammonium nitrogen concentration, ultrasonic energy and sonication period were tested within a range of internal and the resultant sonication performance was evaluated. Sonication was practiced at %98 amplitude of sonicator for 1, 2 and 5 minutes both in acidic, neutral and alkaline conditions. The highest removal was achieved in the test run in which initial pH and ammonia nitrogen concentration were 10 and 20,7 mg N/l regularly and sonication was applied for 5 minutes resulted in the removal of 10,9 mg N/l. The test results showed that ammonia nitrogen removal is more efficient in alkali conditions rather than acidic conditions. The highest removal was observed in the test run in which initial solition pH. Sonication period, sonicator amplitude were 8,5, 5 min and %98 respectively. 10 min sonication period was also applied in the test run in which amplitude was %98 and initial pH and concentrations were which gave size to 52,66 % ammonia nitrogen removal efficiency. In this study 5,6, 41,50, 84,50, 210 and 415,60 mg N/l initial ammonia nitrogen concentration were also tested. Samples had an initial pH 8,5 and sonication period was 5 min. The sample having 415,60 mg N/l initial ammonia concentration resulted in 105 mg N/l removal. In this study the solutions having relatively high ammonia concentrations gave higher removal efficiency. The removal was efficiency short sonication periods and high energy practices.

Benzer Tezler

  1. Düşük frekanslı ultrasonik radyasyonun anaerobik çamur arıtma prosesine etkileri

    Effects of low frequency ultrasonic irradiation on the anaerobic sludge treatment process

    BAHAR İKİZOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    BiyoteknolojiSüleyman Demirel Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. GÖKHAN CİVELEKOĞLU

  2. Design and optimization of compact vivaldi antenna with matching medium for microwave brain imaging applications

    Mikrodalga beyin görüntüleme uygulamaları için eşleştirme ortamına sahip kompak vıvaldı antenin tasarımı ve optimizasyonu

    CAFER UYANIK

    Doktora

    İngilizce

    İngilizce

    2025

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. İBRAHİM AKDUMAN

  3. Fabrication and characterization of nickel oxide functionalized graphene oxide-polyacrylamide nanocomposites

    Nikel oksit ile fonksiyonelleşmiş grafen oksit-poliakrilamid nanokompozitin üretimi ve karakteristik özelliklerinin incelenmesi

    CUMHUR YILDIRIM

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Polimer Bilim ve Teknolojisiİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    PROF. DR. FİGEN KADIRGAN

  4. Mobil telefon kullanımına bağlı oluşan 900-1800 mhz radyo frekans dalgalarının meydana getirdiği elektromanyetik alanın iliak kanat kemik mineral yoğunluğuna etkisi

    The effect of electromagnetic fields on bone mineral density of iliac bone produced by 900-1800 mhz radio frequency waves dependent on cellular phone usage

    BEŞİR ANDAÇ AKSOY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2006

    Ortopedi ve TravmatolojiSüleyman Demirel Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF.DR. NEVRES HÜRRİYET AYDOĞAN

  5. Obtain anterior/posterior position of the tumor through machine learning

    Makine öğrenme yoluyla tümörün anterior/posterior pozisyonunu elde edin

    GOLSHAN GHOLAMPOUR

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    PROF. DR. İBRAHİM AKDUMAN