Geri Dön

Ultrasonik radyasyon ile su ortamından amonyak azotunun uzaklaştırılması

Ammonia nitrogen removal from aqueous solution by ultrasonic radiation

  1. Tez No: 268646
  2. Yazar: EMRAH ÖZTÜRK
  3. Danışmanlar: YRD. DOÇ. DR. NAZİRE MAZLUM
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Amonyak azotu giderimi, sulu çözeltiler, sonikasyon, Ultrason, Ultrasonik inceleme, Ultrasonik yöntemler, Ammonia nitrogen removal, aqueous solutious, sonication, Ultrasound, Ultrasonic study, Ultrasonic methods
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Süleyman Demirel Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, yapay olarak hazırlanan solüsyonlarda amonyak azotu giderimi incelenmiştir. Çalışmada, başlangıç pH, başlangıç amonyum azotu konsantrasyonu, ultrason enerjisi ve ultrason sürelerinde testler yapıldı ve sonuçlara göre ultrasonun performansı değerlendirildi. Sonikasyon işlemi, ultrason ile %98 genlikte 1, 2 ve 5 dakika ultrason sürelerinde, asidik, nötr ve alkali şartlarda uygulandı. Test sonuçları, amonyak azotu giderimi asidik koşullar yerine alkali koşullarda daha etkili olduğunu gösterdi. Uygulanan testlerde yüksek giderimin pH 10 değerinde, başlangıç amonyak konsantrasyonu 20,7 mg N/l'de ve 5 dakika ultrason süresinde 10,9 mg N/l amonyak azotunun giderimi ile sağlandı. En yüksek giderim verimi pH 8,5 değerinde, 5 dakika ultrason süresinde ve %98 genlikte başlangıç konsantrasyonu 18,8 mg N/l olan örnekte gözlendi. 10 dakika ultrason süresi, %98 genlikte ve pH 8,5 değerinde %52,66 amonyak azotu giderim verimine ulaşıldı. Bu çalışmada, 5,6, 41,50, 84,50, 210 ve 415,60 mg N/l başlangıç amonyak azotu konsantrasyonunda testler yapıldı. Örneklere pH 8,5 değerinde ve 5 dakika ultrason uygulandı. Başlangıç konsantrasyonu 415,60 mg N/l olan örnekte 105 mg N/l amonyak azotu giderimi sağlandı. Çalışmada yüksek amonyak konsantrasyonlarına sahip numunelerde daha yüksek boyutta gideri gözlendi. Giderim verimi kısa ultrason süresi ve yüksek enerji uygulamasıyla sağlandı.

Özet (Çeviri)

In this study, removal of ammonia nitrogen in artificial prepared aqueous solutions, has been investigated. In the scape of the study, effects of initial pH, initial ammonium nitrogen concentration, ultrasonic energy and sonication period were tested within a range of internal and the resultant sonication performance was evaluated. Sonication was practiced at %98 amplitude of sonicator for 1, 2 and 5 minutes both in acidic, neutral and alkaline conditions. The highest removal was achieved in the test run in which initial pH and ammonia nitrogen concentration were 10 and 20,7 mg N/l regularly and sonication was applied for 5 minutes resulted in the removal of 10,9 mg N/l. The test results showed that ammonia nitrogen removal is more efficient in alkali conditions rather than acidic conditions. The highest removal was observed in the test run in which initial solition pH. Sonication period, sonicator amplitude were 8,5, 5 min and %98 respectively. 10 min sonication period was also applied in the test run in which amplitude was %98 and initial pH and concentrations were which gave size to 52,66 % ammonia nitrogen removal efficiency. In this study 5,6, 41,50, 84,50, 210 and 415,60 mg N/l initial ammonia nitrogen concentration were also tested. Samples had an initial pH 8,5 and sonication period was 5 min. The sample having 415,60 mg N/l initial ammonia concentration resulted in 105 mg N/l removal. In this study the solutions having relatively high ammonia concentrations gave higher removal efficiency. The removal was efficiency short sonication periods and high energy practices.

Benzer Tezler

  1. Mammografi ve ultrasonografinin meme kanseri tanısında yeri

    Başlık çevirisi yok

    CEBBAR ÇALIŞKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gata

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  2. Ultrases geçiş süresi yönteminin betona uygulanması

    Application of ultrasonic pulse transit time method on concrete

    BİLGE SİYAHİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Anadolu Üniversitesi

    Yükleniyor...

  3. Kaynak dikişlerinin tahribatsız muayenelerine genel bir bakış ve radyografi metodunun etüdü

    Başlık çevirisi yok

    HAKKI ARABACI

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Anadolu Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Over lezyonlarının değerlendirilmesinde ultrasonografinin katkısı

    Başlık çevirisi yok

    İSMET TOLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1988

    Erciyes Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    Yükleniyor...

  5. Modern kaynak usülleri

    Başlık çevirisi yok

    MUHİTTİN ŞİMŞEK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Marmara Üniversitesi

    Yükleniyor...

  6. Farklı kompozisyonlardaki polyesterlerin mekanik özelliklerinin -yapıya bağlı olarak- deneysel ve teorik olarak incelenmesi

    Başlık çevirisi yok

    BEHİYE KORKMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...