Miyoglobin tayinine yönelik moleküler baskılanmış yüzey plazmon rezonans biyosensör hazırlanması

Development of molecular imprinted surface plasmon resonance biosensor for myoglobin determination

  1. Tez No: 286982
  2. Yazar: BİLGEN OSMAN
  3. Danışmanlar: PROF. DR. ADİL DENİZLİ, PROF. DR. NECATİ BEŞİRLİ
  4. Tez Türü: Doktora
  5. Konular: Biyokimya, Kimya, Polimer Bilim ve Teknolojisi, Biochemistry, Chemistry, Polymer Science and Technology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 230

Özet

Bu çalışmada, moleküler baskılama tekniğinin yeni bir yaklaşımı olan mikro-temas baskılama yöntemi kullanılarak yüzey plazmon rezonans (SPR) miyoglobin sensör hazırlandı. Bu amaçla SPR çip yüzeyinde miyoglobin tanıma bölgelerine sahip poli( hidroksietil metakrilat- metakriloil-amidotriptofan metil ester) [poli(HEMA-MATrp)] polimeri ince bir film halinde sentezlendi. Fonksiyonel monomer olarak metakriloil-amidotriptofan metil ester (MATrp) kullanıldı ve metakriloil klorür ile L-triptofan metil esterin reaksiyonu ile sentezlendi. MATrp monomerinin karakterizasyonunda FTIR ve NMR teknikleri kullanıldı. Baskılanmış poli(HEMA-MATrp) film miyoglobinin varlığında MATrp, hidroksietil metakrilat (HEMA) ve etilen glikol dimetakrilatın (EGDMA) polimerizasyonu ile hazırlandı. Kontrol deneyleri için baskılanmamış poli(HEMA-MATrp), kalıp molekül miyoglobin olmadan sentezlendi. Poli(HEMA-MATrp) filmin hazırlanmasında kullanılan modifye altın ve cam yüzeyleri ile miyoglobin baskılanmış film; FTIR, temas açısı ve atomik kuvvet mikroskobu (AFM) ve taramalı elektron mikroskobu (SEM) teknikleri kullanılarak karakterize edildi. Ayrıca hazırlanan filmin kalınlığı elipsometri yöntemiyle ölçüldü. Hazırlanan sensörün etkinliği SPR sistemi kullanılarak araştırıldı. Optimum polimerizasyon koşullarının belirlenmesinden sonra baskılanmış ve baskılanmamış poli(HEMA-MATrp) sensörün miyoglobin tayin duyarlılığı, miyoglobin çözeltileri (pH 7,4 fosfat tamponunda) ve kalp krizi geçiren hasta plazması kullanılarak araştırıldı. Plazma örneklerindeki miyoglobin derişimi ELISA yöntemi ile kıyaslandığında % 66 doğrulukla belirlendi. Farklı derişimdeki miyoglobin çözeltileri ile elde edilen veriler adsorpsiyon kinetiğinin belirlenmesinde kullanıldı. Langmuir adsorpsiyon modelinin, bu afinite sistemi için en uygun model olarak bulundu. Tayin limiti 87,6 ng/mL olarak belirlendi. Miyoglobin baskılanmış poli(HEMA-MATrp) sensörün seçiciliğini göstermek için miyoglobin, lizozim, sitokrom c ve sığır serum albumininin (BSA) yarışmalı adsorpsiyonu araştırıldı. Elde edilen sonuçlar, baskılanmış sensörün miyoglobin için yüksek seçiciliğe ve duyarlılığa sahip olduğunu gösterdi.

Özet (Çeviri)

In this study, surface plasmon resonance (SPR) myoglobin sensor was prepared by using micro-contact imprinting method, a new approach of molecular imprinting. For this purpose, poly(hyroxyethyl methacrylate- methacryloyl-amidotryptophane methyl ester) [poly(HEMA-MATrp)] was synthesized on surface of SPR chip as a thin film. Methacryloyl-amidotryptophane methyl ester (MATrp) was used as functional monomer and synthesized with reaction between methacryoyl chloride and L-tryptophane methyl ester. Characterization of MATrp was made by FTIR and NMR techniques. Imprinted film was prepared with polymerization of MATrp, hydroxyethyl methacrylate (HEMA) and ethyleneglycol dimethacrylate (EGDMA) in the presence of myoglobin. Non-imprinted poly(HEMA-MATrp) was also synthesized without miyoglobin for control experiments. Modified gold and glass surfaces which were used in the preparation of poly (HEMA-MATrp) film and myoglobin imprinted film were characterized with FTIR, contact angle, atomic force microscopy (AFM) and scanning electron microscopy (SEM). In addition, the thickness of the film was measured with ellipsometry. The effectiveness of sensor was investigated by using SPR system. After the determination of optimal polymerization conditions, myoglobin sensing ability of imprinted and non-imprinted sensors were determined with myoglobin solutions (in pH 7,4 phosphate buffer) and in the plasma taken from a patient with myocardial infarction. Compared with the ELISA method, myoglobin concentration in the sample was determined 66% accuracy. Myoglobin solutions with different concentrations were used to determine the adsorption kinetics. Langmuir adsorption model was found as the most suitable model for this affinity system. The detection limit was found as 87,6 ng/mL. In order to show the selectivity of the myoglobin imprinted poly(HEMA-MATrp) sensor, competitive adsorption of myoglobin, lysozyme, cytochrome c and bovine serum albumin (BSA) was investigated. The results show that the imprinted sensor has high selectivity and sensitivity for myoglobin.

Benzer Tezler

  1. Galaktoz oksidaz -miyoglobin hibrid sistemine dayalı mediyatör esaslı yeni bir biyosensör tasarımı

    Desing of a new mediated biosensor based on galactose oxidase- myoglobin hybrid system

    BELGİN SERT SERDAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    BiyokimyaEge Üniversitesi

    Biyokimya Ana Bilim Dalı

    PROF. DR. EROL AKYILMAZ

  2. Akut miyokard enfarktüsü biyogöstergelerinden homosistein, miyoglobin ve yağ asiti bağlayıcı proteinin (FABP) girişimsiz tayini için ters iyontoforez tabanlı elektrokimyasal immünosensörün geliştirilmesi

    Development of a reverse iontophoresis-based electrochemical immunosensor for the noninvasive determination of homocysteine, myoglobin and fatty acid binding protein (FABP), biomarkers of acute myocardial infarction

    FATMA GÜLAY DER

    Doktora

    Türkçe

    Türkçe

    2024

    Eczacılık ve FarmakolojiEge Üniversitesi

    Analitik Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA EMRAH KILINÇ

  3. Ortopedik cerrahide miyokart hücre hasarının izlenmesinde kardiyak Troponin T'nin rolü

    Başlık çevirisi yok

    ERKAN KAYA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2002

    Anestezi ve ReanimasyonEge Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ.DR. F. OĞUZ ERİŞ

  4. Akut koroner sendrom prognoz tayininde multi biyomarkır yaklaşımı

    Multi biomarker approach in acute coronary syndrome prognosis

    EVİN KOCATÜRK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    BiyokimyaEskişehir Osmangazi Üniversitesi

    Tıbbi Biyokimya Ana Bilim Dalı

    PROF. DR. ÖMER ÇOLAK

  5. Miyoglobinin elektrokatalitik indirgenmesine dayalı 2.nesil biyosensör geliştirilmesi ve H2O2 tayininde kullanılması

    Development of 2. generation biosensor based on electrocatalitic reduction of myoglobin and its usage for H2O2 determination

    MEHMET TÜREMİŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    BiyokimyaEge Üniversitesi

    Biyokimya Ana Bilim Dalı

    DOÇ. DR. EROL AKYILMAZ