Kantitatif tayinleri sulu ortamlarda yapılan ve teknikte önemi büyük olan bazı sübstitüe aromatik primer aminlerin susuz ortamlarda tayin edilebilirliklerinin potansiyometrik ve kondüktometrik olarak araştırılması
In nanaqueous media, potentiometric and conductometric investigations of determinability of some technically important substituted aromatic amines which have been determined before quantitatively in aqueous media
- Tez No: 29529
- Danışmanlar: DOÇ. DR. GÜLEREN ÖZKAN
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Susuz ortam, sübstitüe aromatik primer aminler, diazolama metodu, potansiyometrik metot, kondüktometrik metot, Aminler, Kondüktometrik yöntem, Potansiyometri, Sulu ortamlar, Susuz ortamlar, Nonaqueous media, substituted primary aroma tic amines, diazotization, potantiometric method, conducto- metric method, Amines, Conductometric method, Potentiometry, Aqueous media, Non aqueous media
- Yıl: 1993
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Yüksek Lisans Tezi KANT î TAT IF TAYİNLERİ SULU ORTAMLARDA YAPILAN VE TEKNİKTE ÖNEMİ BÜYÜK OLAN BAZI SüBSTITüE AROMATIK PRIMER AMİNLERİN SUSUZ ORTAMLARDA TAYIN edilebilirliklerinin POTANSIYOMETRIK VE KONDüKTOMETRIK OLARAK ARAŞTIRILMASI Selmuş Beniz GÜNDÜZ (EROL) Ankara üniversitesi Fen Bilimleri Enstitüsü Kimya Anabil im Dalı Danışman: Doç. Dr. Güleren ÖZKAN 1993, Sayfa: İM Jüri: Doç. Dr. Güleren ÖZKAN Prof. Dr. Mürşide TüZüN Doç. Dr. Fitnat KÖSEOGLU Çalışmada, sübstîtüe aromatik primer aminlerden o- toluidin, p-toluidin, ^-kloro-E- meti lani 1 in, D-kloroanilin, m-kloroanilin, p-kloroanil in ve p-aminof enolün kantitatif tayinleri önce halen kullanılmakta olan diazolama metoduyla sulu ortamda yapılmıştır. Alman sonuçlar, bu metodun adı geçen aminlerden orto ve para-kloroani linler için uygun ol madığını göstermiştir. Bundan sonra, maddeler susuz ortam larda kantitatif olarak tayin edilmeye çalışılmıştır. Bu a- maçla maddeler önce iyi bir susuz ortam olan nitrobenzende tayin edilmişlerdir. Adı geçen aminlerin bu ortamda yapılan potansiyometrik tayinlerinden, yüzde 100 geri kazanma veri mi ile tayin edilebilecekleri sonucuna varılmıştır. Bu iki metot orto ve para-kloroanilinlerin haricinde tamamen bir birini desteklemektedir. Ayrıca bu aminlerin asetik asit ortamında potansiyometrik ve kondüktometrik titrasyonları yapılmak istenmiş ancak tatmin edici sonuçlar alınamamıştır.
Özet (Çeviri)
11 ABSTRACT Masters Thesis IN NONAQUEOUS MEDIA, POTENTIOMETRIC AND CONDUCTOMETR I C INVESTIGATIONS OF DETERMIN ABILITY OF SOME TECHNICALLY IMPORTANT SUBSTITUTED AROMATIC AMINES WHICH HAVE BEEN DETERMINED BEFORE QUANTITATIVELY IN AQUEOUS MEDIA Selmus Beniz GÜNDÜZ (EROL) Ankara University Graduate School of Natural and Applied Sciences Department of Chemistry Supervisor: Assoc. Prof.Dr. Güleren ÖZKAN 1993, Page: 10<» Jury: Assoc.Prof.Dr. Güleren ÖZKAN Prof.Dr. Mürşide TüZüN Assoc. Prof.Dr. Fitnat KÖSEOGLÜ In this work, technically important some substituted primary aromatic amines namely o-toluidine, p-toluidine, 4- chloro-B-methy 1 aniline, o-chloroanil ine, m-chloroani 1 ine, p-chloroaniline and p- aminophenol have been at first quan titatively determined by diazotization method which is cur rently used in aqueous media. The results obtained by this method have shown that this method is appropriate for these compounds other than ortho and para-chloroani lines. After that, these amines have been tried to determine in nonaque ous media. In order to verify this, the compounds have been firstly determined in nitrobenzene solvent which is one of the good nonaqueous medium. Potentiometric titrations of these amines in nitrobenzene have indicated that these com pounds can be determined by a hundred percent recovery. Di azotization and potentiometric methods have supported comp letely each other excluding the determinations of ortho and para-chloroanilines. In addition to these, the compounds have been tried to determine by potent iometr ical ly and con- ductometrical ly in dry acetic acid solvent but the results were not satisfactory.
Benzer Tezler
- Method development for the determination of fluorine by high resolution continuum source atomic absorption spectrometry
Yüksek çözünürlüklü sürekli kaynaklı atomik absorpsiyon spektrofotometrelerde flor tayini için yöntem geliştirilmesi
NİL ÖZBEK
- Aza–bodipy compounds with fluorescent property for determination of bio–thiols
Biyo–tiyollerin tayini için floresan özellikli aza–bodipy bileşikleri
BLEDA CAN SADIKOĞULLARI
Yüksek Lisans
İngilizce
2019
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
DOÇ. DR. AYŞE ÖZDEMİR
- İnorganik arsenik bileşiklerinin HPLC/UV yöntemi ile tayinleri
Determination of inorganic arsenic compounds by HPLC/UV method
MERTCAN ÖKSÜZ
- Kuru incirlerde küf florası ve aflatoksigenik küflerin saptanması
Başlık çevirisi yok
SİBEL BÜYÜKŞİRİN
- Deniz suyu ve mineral sulardaki bazı eser elementlerinin Al (OH)3 ile birlikte çöktürülerek ayrılması ve faas ile tayini
Separation of some trace elements in seawater and mineral water by coprecipitation with aluminum hydroxide and their determination by flame atomic absorption spectrometry
ASLI EGE