Geri Dön

Ksantin ve ürik asit tayini için farklı medyatörlü modifiye karbon pasta enzim elektrotların hazırlanması

Preparation of modified carbon paste enzyme electrodes with different mediators for determination of xanthine and uric acid

  1. Tez No: 297537
  2. Yazar: PINAR ESRA ERDEN
  3. Danışmanlar: PROF. DR. ESMA KILIÇ
  4. Tez Türü: Doktora
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 184

Özet

Bu çalışmada ürik asit ve ksantin tayini için farklı medyatörlü dört ayrı amperometrik enzim elektrot hazırlandı. Bu amaçla ürikaz ve ksantin oksidaz enzimleri, karbon pasta matrikse çapraz bağlama yöntemi ile immobilize edildi. Ürik asit ve ksantin tayini, enzimatik olarak oluşan hidrojen peroksitin sabit potansiyelde yükseltgenmesine dayanarak yapıldı. Enzim elektrotların optimum elektrot bileşimi, çalışma koşulları, performans faktörleri ve gerçek numunelerde madde tayininde kullanılabilirliği araştırıldı. 1,4-Benzokinon modifiye ürik asit enzim elektrodu için optimum enzim ve medyatör miktarı, tampon, sıcaklık ve çalışma potansiyeli sırasıyla 2 U, 3 mg, 0,2 M, pH 8,0 tris tamponu, 30 ? C ve +0,25 V olarak bulundu. Enzim elektrodun çalışma aralığı 1,9×10-8-2,7×10-3 M, gözlenebilme sınırı 1,9×10-8 M, cevap süresi 150 s, raf ömrü 12 gün ve tekrar kullanılabilirlik çalışmasında çizilen kalibrasyon eğrilerinin bağıl standart sapması %4,7 olarak belirlendi. PVF modifiye ürik asit enzim elektrodu için optimum enzim ve medyatör miktarı, tampon, sıcaklık ve çalışma potansiyeli sırasıyla 2 U, 2,5 mg, 0,05 M, pH 8,0, fosfat tamponu, 40 ? C ve +0,70 V bulundu. Enzim elektrodun çalışma aralığı 7,4×10-8-7,0×10-3 M, gözlenebilme sınırı 7,4×10-8 M, cevap süresi 120 s, raf ömrü 14 gün ve tekrar kullanılabilirlik çalışmasında bağıl standart sapma %6,2 olarak belirlendi. Her iki elektrotla da serumda ürik asit tayini yapıldığında standart kit metodu ile uyumlu sonuçlar elde edildi. 1,4-Benzokinon modifiye ksantin enzim elektrodu için optimum enzim ve medyatör miktarı, tampon ve çalışma potansiyeli sırasıyla 0,8 U, 2 mg, 0,05 M, pH 7,5 fosfat tamponu ve +0,25 V olarak bulundu. Enzim elektrodun ksantin için çalışma aralığı 1,9×10-7-8,2×10-4 M, gözlenebilme sınırı 1,0x10?7 M, cevap süresi 100 s, raf ömrü 14 gün ve tekrar kullanılabilirlik çalışmasında bağıl standart sapma %3,5 olarak belirlendi. Elektrot hipoksantine ise 2,0x10?7 M gözlenebilme sınırı ile 2,9×10-7-1,5×10-3 M aralığında doğrusal cevap gösterdi. Bu elektrot ile idrarda ksantin tayininde %100'e yakın geri kazanımlar elde edildi. PVF modifiye ksantin enzim elektrodu ile 0,10 M pH 7,0 fosfat tamponunda, +0,30 V'da çalışıldı ve ksantin için çalışma aralığı 1,9×10-7 M-8,8×10-4 M, gözlenebilme sınırı 1,0x10?7 M, cevap süresi 50 s, raf ömrü 1 hafta ve tekrar kullanılabilirlik çalışmasında bağıl standart sapma %7,2 olarak belirlendi. Elektrodun hipoksantin için çalışma aralığı 1,0×10-5 M-3,0×10-4 M bulundu. Tüm elektrotların cevaplarına biyolojik ortamlarda bulunan ve girişim yapan türlerin etkisi incelendi.

Özet (Çeviri)

In this study, four different amperometric enzyme electrode for the determination of uric acid and xanthine were developed. For this purpose uricase and xanthine oxidase enzymes were immobilized to carbon paste matrix by cross linking. Uric acid and xanthine determination was performed due to the oxidation of enzymatically produced H2O2 at constant potential. Optimum electrode composition, working parameters, performance factors and usibility for determination of real samples were investigated. For the 1,4-benzoquinone modified uric acid enzyme electrode optimum enzyme and mediator amount, buffer, temperature and working potential were found as 2U, 3 mg, 0.2 M pH 8.0 tris buffer, 30 ? C and +0.25 V respectively. The working range of the electode was 1.9×10-8-2.7×10-3 M, limit of detection was 1.9×10-8 M, response time was 150 s, storage stability was 12 days and relative standart deviation of the calibration graphs of reproducibility was %4.7. For the PVF modified uric acid enzyme electrode optimum enzyme and mediator amount, buffer, temperature and working potential were found as 2U, 2.5 mg, 0.05 M pH 8.0, phosphate buffer, 40 ? C and +0.70 V respectively. The working range of the electode, limit of detection, response time, storage stability and relative standart deviation of reproducibility were reported as 7.4×10-8-7.0×10-3 M with a detection limit of 7.4×10-8 M, 120 s, 14 days and %6.2 respectively. There was a good linear relationship between uric acid levels measured by both electrodes and standart kit method. Optimum enzyme and mediator amount, buffer and working potential were found as 0.8U, 2 mg, 0.05 M pH 7.5 phosphate buffer and +0.25 V respectively for the 1,4-benzoquinone modified xanthine enzyme electrode. Working range, limit of detection, response time, storage stability and relative standart deviation of reproducibility for xanthine were found as 1.9×10-7-8.2×10-4 M, 1.0x10?7 M, 100 s, 14 days and %3,5 with 1,4-benzoquinone modified xanthine enzyme electrode. Working range of this electrode for hypoxanthine was between 2.9×10-7-1.5×10-3 M with a detection limit of 2.0x10?7 M. Nearly about 100% recoveries were obtained for xanthine detection in urine with this electrode. Measurements were performed in 0.10 M pH 7.0 phosphate buffer at +0.30 V with the PVF modified xanthine enzyme electrode and working range, limit of detection, response time, storage stability, standart deviation for reproducibility were found as 1.9×10-7-8.8×10-4 M, 1.0x10?7 M, 50 s, 1 week and %7.2 respectively. Working range of this electrode for hypoxanthine was 1.0×10-5-3.0×10-4 M. Influence of the interferances were investigated for all electrodes.

Benzer Tezler

  1. Alt ekstremitede iskemi/ reperfüzyon sonrası oluşan serbest oksijen radikallerinin böbreğe etkisi ve oksijen süpürücülerinin rolü

    The Effect of free oxygen radicals on kidney after ischemia and reperfusion of lower extremities and the role of oxygen radical scavengers

    K. TEKİN İNCE

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1996

    Genel Cerrahiİstanbul Üniversitesi

    PROF.DR. MURAT KAYABALI

  2. Eczacılıkta elektrokimyasal (biyo)sensör tasarımları ve uygulamaları

    Başlık çevirisi yok

    MUSTAFA EMRAH KILINÇ

    Doktora

    Türkçe

    Türkçe

    2000

    Eczacılık ve FarmakolojiEge Üniversitesi

    Analitik Kimya Ana Bilim Dalı

    PROF. DR. M. E. ŞENGÜN ÖZSÖZ

  3. Ürik asitin elektrokimyasal tayini için yeni bir sensör hazırlanması

    Preparation of a new sensor for electrochemical determination of uric acid

    GİZEM TÜRKKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    KimyaSelçuk Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA ÖZMEN

  4. Reaktif oksijen türleri süpürücü antioksidan aktivitenin ölçümünde modifiye CUPRAC yöntemlerinin geliştirilmesi

    Development of modified CUPRAC methods for reactive oxygen species scavenging antioxidant activity measurement

    MUSTAFA ÖZYÜREK

    Doktora

    Türkçe

    Türkçe

    2009

    Kimyaİstanbul Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. REŞAT APAK

  5. Balıkta tazeliğin belirlenmesine yönelik biyosensör tasarımı

    A new biosensor design for determination of fish meat freshness

    PELİN ÖZKAYA

    Doktora

    Türkçe

    Türkçe

    2024

    Bilim ve TeknolojiManisa Celal Bayar Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SEVAL DAĞBAĞLI